• Title/Summary/Keyword: Power-Saving

Search Result 1,284, Processing Time 0.03 seconds

Analysis on the Performance Test Results of Heat Pump for the Closed Cooling Water Heat Recovery on Combined Thermal Power Plant (복합화력발전소의 냉각수 배열회수를 위한 히트펌프의 성능평가)

  • Lee, Sung-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.2
    • /
    • pp.43-48
    • /
    • 2016
  • This study proves successes of Energy Service Company (ESCO) business by heat pump performance test. The purpose of ESCO business is recover investment costs through saving energy from installation of energy reduction facility. The most important technology assessment items are heat recovery and generator output. Experimental result shows that increase quality of heat recovery (11.52Gcal/h), while decrease generator output (0.234kw). In its final analysis, the ESCO business is successful according to our data.

A Control Method of Electric Railway Vehicle Recycle Energy Storage System Using Supercapacitor (슈퍼커패시터를 이용한 전동차량 화생 에너지 저장 시스템의 제어기법)

  • Noh, Se-Jin;Lee, Jin-Mok;Son, Kyoung-Min;Choi, Jae-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.97-99
    • /
    • 2008
  • It is possible to suppress voltage drops, power loading fluctuations and regeneration power lapses for DC railway systems by applying an energy storage system. Recently the electric double layer capacitor (EDLC) of the rapid charge/discharge type has been developed and used in wide ranges. The on board energy storage system with supercapacitor for railway vehicles presented in this paper seems to be a reliable technical solution with an enormous energy saving potential. In this paper, an efficient charge and discharge control method of a bidirectional DC-DC converter using the supercapacitor is proposed.

  • PDF

Low-Power-Adaptive MC-CDMA Receiver Architecture

  • Hasan, Mohd.;Arslan, Tughrul;Thompson, John S.
    • ETRI Journal
    • /
    • v.29 no.1
    • /
    • pp.79-88
    • /
    • 2007
  • This paper proposes a novel concept of adjusting the hardware size in a multi-carrier code division multiple access (MC-CDMA) receiver in real time as per the channel parameters such as delay spread, signal-to-noise ratio, transmission rate, and Doppler frequency. The fast Fourier transform (FFT) or inverse FFT (IFFT) size in orthogonal frequency division multiplexing (OFDM)/MC-CDMA transceivers varies from 1024 points to 16 points. Two low-power reconfigurable radix-4 256-point FFT processor architectures are proposed that can also be dynamically configured as 64-point and 16-point as per the channel parameters to prove the concept. By tailoring the clock of the higher FFT stages for longer FFTs and switching to shorter FFTs from longer FFTs, significant power saving is achieved. In addition, two 256 sub-carrier MC-CDMA receiver architectures are proposed which can also be configured for 64 sub-carriers in real time to prove the feasibility of the concept over the whole receiver.

  • PDF

Stability Analysis of Compressed Air Storage Caverns in Rockmass (전력생산을 위한 암반내 압축공기저장공동의 안정성분석)

  • 신희순;신중호;최성웅;한일영;김정엽
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.287-294
    • /
    • 2002
  • CAES which is called as a compressed air energy storage was firstly developed at Huntorf, German in 1978. The capacity of that system was 290MW, and it can be treated as a first commercial power plant. CAES has a lot of merits, such as saving the unit price of power generation, averaging the peak demand, improvement of maintenance, enlarging the benefit of dynamic use. According to the literature survey, the unlined rock cavern should be proposed to be a reasonable storing style as a method of compressed air storage in Korea. We decided the hill of the Korea Institute of Geoscience and Mineral Resources as CAES site. If we construct the underground spaces in this site, the demand for electricity nearby Taejon should be considered. So we could determine the capacity of the power plant as a 350MW, This capacity needs a underground space of 200,000㎥, and we can conclude 4 parallel tunnels 550m deep from the surface through the numerical studies, Design parameters were achieved from 300m depth boring job and image processing job.

  • PDF

The Design and Implementation of Electromotion Curtain System using PLC and CDM Controller

  • Choo, Yeon-Gyu;Kang, Sung-Soo;Kim, Bong-Gi
    • Journal of information and communication convergence engineering
    • /
    • v.8 no.4
    • /
    • pp.443-448
    • /
    • 2010
  • The electrical curtain is an electronic product which is most suitable for the sphere of intelligent home network. It provides the basic feature of intelligent home network such as the followings; various functions, powerful control. It also becomes the ideal technology with inexpensive power-line protocol, energy saving and solar power generation. Generally it is a suitable motor for BLDC to move the electrical curtain, because it provides the maintenance without difficulty, long-lived use with good efficiency. On this paper, we proposed the BLDC motor controller designed by CDM(Coefficient Diagram Method) and evaluated its performance with a simulation of the plant, designed the electrical curtain using BLDC motor and powe-line protocol.

Single Electronic Drive Controlling Two Synchronous Motors Via Modified Vector Control

  • Danbing Seto;Fanping Sun;Jacek F. Gieras;Norbert A.M. Hootsmans
    • Journal of Power Electronics
    • /
    • v.3 no.1
    • /
    • pp.49-54
    • /
    • 2003
  • A novel control scheme of using a single electronic drive to synchronize two synchronous motors is investigated analytically. The developed control strategy extends the conventional vector control technology, Specifically, it utilizes the property that the motion of two motors can be independently controlled by the q-axis currents provided the desired q-axis currents can be achieved by adjusting physical armature currents. The latter part is indeed guaranteed by adding a position offset to one of the motors. This work has a potential of cost saving in practice where the cost of drive is a major concern.

Induction motor vector control for washing machine (드럼 세탁기용 유도전동기의 효율운전)

  • Lee, Dong-Yup;Lee, Won-Chul;Bae, Woo-Ri;Kim, Lee-Hun;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.36-38
    • /
    • 2005
  • In home appliances, electric energy is optimally controlled by using power electronics technology, creating a comfortable environment in terms of energy saving, low sound generation, and reduced time consumption. Usually simplicity and robustness make the three phase induction motor attractive for use in domestic appliance, including washing machines. Two main types of domestic washing machine have evolved. We focus on the front loading machine favored in Europe, which has a horizontal drum axis. The efficiency improvement in home appliances is very important for customers. Induction motor efficiency can be improved by means of loss reduction, which can be realized by motor selection and design, improvement of the waveforms supplied by power Inverter, utilizing a suitable control method. So this paper describes the architecture and feature of washing machine fed induction motor drive under minimizing losses vector control.

  • PDF

Power-aware Ad hoc On-Demand Distance Vector Routing for prolonging network lifetime of MANETs

  • Hoang, Xuan-Tung;Ahn, So-Yeon;Lee, Young-Hee
    • Annual Conference of KIPS
    • /
    • 2002.11b
    • /
    • pp.1317-1320
    • /
    • 2002
  • We present in this paper a new version of AODV that incorporates with "Minimizing Maximum node cost" by formulating that metric as a cost function of residual energy of nodes. An additional parameter is added to the cost function to consider the routing performance along with power-efficiency. The motivation of adding that new parameter is originated from the trace off between power-saving behaviors and routing performance.

  • PDF

A Study on the data link between SCADA and DAS (한전 변전자동차시스템과 배전자동화시스템의 자료연계방안에 관한 연구)

  • Ko, Sang-Chen;Kim, Yong-Pal
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2393-2395
    • /
    • 1998
  • Today it is hard to imagine the operation of power network and its facilities without the control systems such as EMS/SCADA/DAS. In KEPCO, data links to the upper layer of control system (SCABA) is required to launched DAS project lately, in terms of the needs of saving cost for the data gathering facilities (RTU) in the substation that previously equipped SCADA RTU. In this Paper we researched the circumstance of the KEPCO SCADA systems for data link and present the scheme of the data link between DAS and SCADA.

  • PDF

Utility Interactive Inverter with High-frequency Link for Photovoltaic Power System (고주파링크 방식을 이용한 계통연계형 태양광발전시스템)

  • Jung, Y.S.;Yu, G.W.;Lee, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1050-1052
    • /
    • 2000
  • An investigation into power conditioners that interface with photovoltaic array and utilities has been completed. The rating for this investigation is residential system (3-5kW) that interface with a 220V single phase utility connection. As the result of this investigation. a 3kW high frequency PWM IGBT inverter feeding a high frequency isolation transformer with a sinusoidal current wave was selected. The output of the transformer rectified with a diode bridge rectifier four IGBT, used as 60Hz switched, reverse the polarity of the rectified current on every other half cycle of the utility voltage. Even though the high frequency link system used more power semiconductors, a net size, weight, and parts cost saving result compared to the other systems due to elimination of 60Hz transformer.

  • PDF