• Title/Summary/Keyword: Power-Saving

Search Result 1,284, Processing Time 0.025 seconds

Real-Time Power-Saving Scheduling Based on Genetic Algorithms in Multi-core Hybrid Memory Environments (멀티코어 이기종메모리 환경에서의 유전 알고리즘 기반 실시간 전력 절감 스케줄링)

  • Yoo, Suhyeon;Jo, Yewon;Cho, Kyung-Woon;Bahn, Hyokyung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.1
    • /
    • pp.135-140
    • /
    • 2020
  • Recently, due to the rapid diffusion of intelligent systems and IoT technologies, power saving techniques in real-time embedded systems has become important. In this paper, we propose P-GA (Parallel Genetic Algorithm), a scheduling algorithm aims at reducing the power consumption of real-time systems in multi-core hybrid memory environments. P-GA improves the Proportional-Fairness (PF) algorithm devised for multi-core environments by combining the dynamic voltage/frequency scaling of the processor with the nonvolatile memory technologies. Specifically, P-GA applies genetic algorithms for optimizing the voltage and frequency modes of processors and the memory types, thereby minimizing the power consumptions of the task set. Simulation experiments show that the power consumption of P-GA is reduced by 2.85 times compared to the conventional schemes.

Research on using the exhausted heat from subway tunnel as unused energy (미활용 에너지원으로서의 지하철 배열이용에 관한 연구)

  • 김종렬;금종수;최광환;윤정인;박준택;김동규;김보철;정용현
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.6
    • /
    • pp.695-701
    • /
    • 1998
  • Researches on unused energy are being continued because of the limited fossil fuel and the destruction of environment. Therefore this study was peformed as follows. The collectable amount of exhausted heat for an air-conditioning was calculated by the subway thermal environment prediction program. And the electric power needed by conventional heat source equipments was compared with one by unused heat source equipments when the exhausted heat was used by heat pump in heating and hot water supplying. The results are summarized as follows; 1) Forced ventilation should be conducted to keep optimal temperature in subway tunnel in summer as well as in winter. According to the simulation, temperature in tunnel was higher than that on the ground in summer when the forced ventilation was conducted only in winter. 2) Ventilating time should be calculated out to the optimal condition for not only saving power of ventilation fan but reusing exhausted heat. By the simulation, it is certain that the exhausted heat should be eliminated in air-conditioning time. 3) The use of exhausted heat source heat pump could save 8% of electric power per hour in comparison with existing heat pump. It was based on a present heat generation and traffic for ventilating time of general air-conditioning, but could be different by ventilating time. 4) As the traffic increases up to 1.5 or 2 times, electric power consumption of the conventional heat pump increases to 11% or 13.5% per mean hour in comparison with that of the exhausted heat source heat pump, though all-day ventilation.

  • PDF

Communication Module Selection Algorithm for Energy Saving of Smartphone (스마트폰 에너지 절감을 위한 통신모듈 선택 알고리즘)

  • Lee, Chang-Moo;Lee, Seung-Jae;Choi, Deok-Jai
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.5
    • /
    • pp.22-31
    • /
    • 2012
  • A Smartphone is an intelligent device combined mobile phone and pc's support functions, and can perform multiple functions to satisfy the demands of users. It has excellent processing power and communication modules(DMB, Wi-Fi, Bluetooth, NFC etc) to carry out the demands of users. But continuous using of battery power on processor and equipped modules causes acceleration of battery consumption. This means that effective power management in devices like smartphone is important. Therefore, the management of power consumption on system execution and communication module is a serious issue in this field of study. In this paper, we would like to propose a communication module selection algorithm based on energy consumption parameter of each communication module and data transfer time. Our scheme automatically select appropriate communication system to reduce high energy consumption on bluetooth sleep mode so that this scheme is more efficient and effective thus improving user convenience in longer usage time. Experimental results showed the 20% energy saving.

Development of Power Energy Management System for Ships including Energy Saving of Separated Load Systems (개별 부하 시스템의 에너지 절감을 포함한 선박 전력 에너지 관리 시스템 개발)

  • Kang, Young-Min;Oh, Jin-Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.1
    • /
    • pp.131-139
    • /
    • 2018
  • Many ship researches have been carried out in connection with the fourth revolution, one of which focuses on EMS(energy management system). The EMS is referred to as systems for managing the energy of ships and include various systems. In this paper, we analyze the energy saving field in ship and propose a ship power energy management system including individual load control systems that can save energy in the engine room. EMS includes individual load control systems of PCS (Pump Control System), ERFCS (Engine Room Fan Control System), LCS (Load Control System), HVACS (Heating, Ventilation, Air conditioning Control System). Proposed EMS primarily conserves energy in the individual load systems of the engine room. Secondly, the integrated monitoring and control system is used to control the power generation system and the power load system to save energy.

Studies on the Application of Unit-inverter Parallel Operation to Sea-water Lift Pump in Power Plant (단위 인버터 병렬운전에 의한 발전소 해수펌크 적용)

  • 김수열;류홍우
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.1
    • /
    • pp.1-7
    • /
    • 1998
  • Due to the increase in capacity of auxiliary machinery in power plant, the importance of energy saving has been greatly emphasized. If the speed of fans or pumps is controlled in accordance with the variation of load, large electric energy can be saved. Large capacity inverter, 2MVA GTO inverter, has been developed by operating two of 1MVA unit inverters in parallel. The parallel operation of the unit inverter is accomplished through two output transformers of which the secondary windings are connected in series. The system is composed of one control cubicle, one rectifier cubicle and 2 unit inverter cubicles. This inverter system was applied to the sea water lift pump(SLP) driven by a 6.6KV 1500KW induction motor in Seo-Inchon power plant to save the electric energy. The parallel operation of inverters by 180 degrees apart in switching frequency helps to reduce the harmonic components.

Optimization Techniques for Power-Saving in Real-Time IoT Systems using Fast Storage Media (고속 스토리지를 이용한 실시간 IoT 시스템의 전력 절감 최적화 기술)

  • Yoon, Suji;Park, Heejin;Cho, Kyungwoon;Bahn, Hyokyung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.6
    • /
    • pp.71-76
    • /
    • 2021
  • Recently, as the size of IoT data grows, the memory power consumption of real-time systems increases rapidly. This is because real-time systems always place entire tasks in memory, which increases the demand of DRAM significantly. In this paper, we adopt emerging fast storage media and move a certain portion of real-time tasks from DRAM to storage. The part of tasks in storage are, then, loaded into memory when they are actually used. We incorporate our memory/storage power-saving into the dynamic voltage/frequency scaling of processors, thereby optimizing power consumptions in CPU and memory simultaneously. Specifically, the proposed technique aims at minimizing the CPU idle time and the DRAM memory size by determining appropriate voltage modes of CPU and the swap ratio of memory, without violating the deadlines of all tasks. Through simulation experiments, we show that the proposed technique significantly reduces the power consumption of real-time systems.

A Study on Energy Saving Monitoring System of Data Center based on Context Awareness (상황인지 기반 데이터센터의 전력절감 모니터링 시스템에 관한 연구)

  • Lee, Hwa-Jeong;Jung, Min-Yong;Kim, Chang-Geun;Kim, Hyun-Ju
    • Journal of Convergence for Information Technology
    • /
    • v.9 no.1
    • /
    • pp.19-27
    • /
    • 2019
  • In recent years, with the advancement of IT technology, we expect data size of the world to increase 10 times in 2025. The rapid development of this Internet technology leads to the downsizing of the server system of the data center which manages and operates the data, the capacity of the storage medium, and the power consumption of the data center. In this paper, we propose an energy conservation policy and analyze it in real time by analyzing the power consumption pattern of the server system of the data center. The proposed system can monitor and analyze the power consumption pattern of the individual server system in the data center, and it can be expected that about 10% of the total power consumption of the data center will be saved by efficiently managing the actual operation time of the server system.

A Node Grouping Method for Transmission Power Saving in Underwater Acoustic Sensor Network (수중 센서 네트워크에서 노드 그룹화를 통한 전송전력 절약 방안)

  • Hwang, Sung-Ho;Cho, Ho-Shin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.8
    • /
    • pp.774-780
    • /
    • 2009
  • This paper proposes a transmitted power saving method for underwater acoustic sensors considering the acoustic wave propagation characteristic that propagation loss increases more rapidly in higher frequency band. In the proposed scheme, sensor nodes are divided into a few groups based on the distance between sink node and the sensor node, and each group uses its own frequency band. The node group with longer distance uses lower frequency and the node group with shorter distance uses higher frequency. By means of such a distance-dependent frequency allocation, all sensor nodes are able to maintain a certain target signal-to-noise ratio (SNR), but also save transmitted power. In addition, the optimum size of node group is obtained, and also a frequency allocation algorithm is proposed accordingly. Numerical results show that the proposed scheme saves transmitted power by more 10 dB comparing non-grouping methods.

A Study on the Turbine Performance in the steam seal variable clearance packing type of Steam turbine (증기터빈의 가변패킹 형태에 따른 터빈성능 평가에 관한 연구)

  • Kweon, Y.S.;Suh, J.S.
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1676-1681
    • /
    • 2004
  • The main reason for applying positive pressure variable clearance packing in fossil power plant is high efficiency and energy saving movement in the government. This study intends to analyze the turbine efficiency through the shaft packing improvement in thermal power plant and makes its comparison to that of the each packing type

  • PDF

AN ENERGY ANALYSIS ON GRAIN DRYING SYSTEMS IN CHINA

  • Shao, Y.J.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.906-911
    • /
    • 1993
  • There will be about 0.25 to 0.3billion tons of grain product including rice, wheat and corn etc. each year in China. An energy analysis on grain drying system on which electricity , oil , coal or sun power and batch, tower with thick or thin layer of grain, infra red radiation. fluidized flowing types grain drying systems were made and compared for the sake of energy saving is shown in this paper.

  • PDF