• Title/Summary/Keyword: Power-Saving

Search Result 1,284, Processing Time 0.036 seconds

Intelligent Energy Saving Power System Controller for Telecom DC Power Plant (통신교환기용 DC 전원시스템을 위한 에너지 절약형 지능제어기)

  • Kim, I.J.;Gu, S.W.;Kim, T.Y.;Choi, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.323-325
    • /
    • 1996
  • The design of Intelligent Energy Saving Power System Controller (IESPSC) for Telecom DC power plants is proposed and presented in this paper. From the past experience. rectifiers for Telecom DC power plants have been operated inefficiently at light loads. IESPSC offers "novel load sharing" approach based on the knowledge of each unit's efficiency of paralleled rectifiers. Neural networks is used for identifying each rectifier's efficiency characteristic curve corresponding to load currents, which is in turn utilized to produce a system efficiency close to the maximum under all operating conditions. In addition, by limiting the number of operating units to the minimum while maintaining high efficiency at the determined loads, a drastic savings in operating cost can be achieved.

  • PDF

Design and Implementation of a Power-Saving Management System using Intelligent Scheduler based on RFID/USN Technology (RFID/USN 기술 기반의 지능형 스케줄러를 이용한 절전관리 시스템 설계 및 구현)

  • Jeong, Kyu-Seuck;Choi, Sung-Chul;Jeong, Woo-Jeong;Kim, Tae-Ho;Kim, Jong-Heon;Seo, Dong-Min;Park, Yong-Hun;Yoo, Jae-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.64-76
    • /
    • 2009
  • Recently, the ubiquitous environment and the practical technology associated with it become more popular topic along with the rapid development of wireless technologies. The necessity of the automated system based on the ubiquitous environment has been increasing when the concept of the ubiquitous is integrated into the fields of existing IT. Also, the necessity of formulating a power-saving plan on large buildings and public institutions is gathering strength because of a raise in exchange rates and high oil prices. In this paper, to efficiently manage the power consumption of the electronic machine such as electric lights, electric heaters, and air conditioners in a building, power-saving manage- ment system using RFID/USN technologies is proposed. Proposed system controls the electric machine and monitor it's condition by RFID and collects the real time information about the surrounding and the power consumption of the electric machine by USN. Especially, proposed system analyzes the real time information and supports the intelligent scheduler with the best power-saving. Finally, this paper shows the difference between proposed system and existing system and establishes thereality of our system through experiments in variety environments.

A Study on Control and Monitoring System for Building Energy Management System

  • Oh, Jin-Seok;Bae, Soo-Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.3
    • /
    • pp.335-340
    • /
    • 2011
  • Building energy saving is one of the most important issues in these days. Control algorithm for energy saving should be designed properly to reduce power consumption in building. Recently, building energy system consists of hybrid energy system coupling with RE (Renewable Energy) source. In this paper, an optimum control algorithm for building energy saving is applied to BEMS (Building Energy Management System) by using an outdoor air temperature prediction strategy. BEMS coupling with renewable energy can control HVAC (Heating, Ventilating and Air-Conditioning) system effectively. In order to verify the effectiveness of building energy saving, BEMS was tested for several months at a laboratorial chamber with an air conditioner, fan and heater. To this end BEMS embedded control algorithm has been tested successfully.

A Economic Feasibility Analysis of Energy Saving Technology Application to Underground Subway Station

  • Kim, Hyungchul;Shin, Seungkwon;Jung, Hosung;Kim, Jin-o;Cha, Junmin
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.7 no.2
    • /
    • pp.36-40
    • /
    • 2015
  • In Korea, new total energy-saving solution has planned to build test-bed in underground subway station. Breaking energy is one of the most energy saving method in railway, but it has not be fully used up for economical purpose. This paper demonstrates on energy saving technology application including breaking energy and heating energy to underground subway station. It also offer solution of optimization of power energy flow. Moreover, economic feasibility analysis performed for undergound test bed constuction.

A Simulation Study on the Energy Saving Strategy of Train Operation (에너지절약을 위한 열차운행전략에 관한 시뮬레이션 연구)

  • Joo, Young-Bhok;Choi, Kyu-Hyoung
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1594-1598
    • /
    • 2007
  • Energy saving is an important topic for each heavy user of the power system, including railway operators. Therefore, four strategy of train operations studied that maximum speed reduction, reduced acceleration rate, anticipatory coasting, and saw-tooth coasting for energy saving. The Simulation model of the study used to investigate the performance of a railway system, and it was used to study the effect of energy saving strategies for the train operation. The Study investigate train operation strategy for energy saving, investigate the effect of strategy, and find the energy optimization of acceleration, coasting, braking section used Run-Curve simulator from train data.

  • PDF

NON CONVENTIONAL METHOD FOR SOFT STARTING OF THREE PHASE INDUCTION MOTORS

  • Ahmed Nabil A.;Kim Sung-Jun;Suh Ki-Young;Kown Soon-Kurl;Lee Hyun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2004.11a
    • /
    • pp.27-31
    • /
    • 2004
  • This paper presents a nonconventional method for oft starting of three-phase induction motors, which achieved by flux weakening technique. flux weakening is not done by reducing the applied voltage as in the conventional methods, Flus weakening is achieved y increasing the supply frequency over the rated value while the voltage amplitude is kept constant. This method has advantage of reducing the stress on the electrical and mechanical systems. The feasibility of this basic idea has been confirmed through investigating the starting transient corresponding to this mode of operation. For this purpose, a rigorous state space mathematical model has been developed and simulated. The validity of the proposed method through the results from the mathematical model have been confirmed experimentally.

  • PDF

Indicators of Economic Evaluation and Case Studies on New & Renewable Energy (신재생에너지 경제성 평가 결과 분석 및 평가지표 연구)

  • Ahn Eun-Young;Kim Seong-Yong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.600-603
    • /
    • 2005
  • U.S. National Research Council proposed benefits framework for energy R&D project as economic benefits, environmental benefits, security benefits and knowledge benefits. Following this framework, U.S. National Renewable Energy Laboratory evaluated the projected benefits of Federal Energy Efficiency and Renewable Energy Programs in the indicators of energy-expenditure savings, energy system cost savings, $CO_2$ emissions reductions. oil savings, natural gas saving and avoided additions to central conventional power. As this result, geothermal energy have predominant position in the energy-expenditure savings, natural gas saving and avoided addi t ions to central conventional power to FY2050. The projected benefits, in monetary value, of the whole supply-potential of geothermal energy in Korea were evaluated as 480.2 billion Won, 43.1 billion Won and 135.8 billion Won for the private energy-cost savings, social environmental-cost savings, and import energy-cost saving, respectively.

  • PDF

Effect of Lighting Saving Using High Efficiency Reflector (고효율 반사갓을 이용한 등기구 저감효과)

  • Cho, Huyn-Kyung;Kim, Jae-Chul;Jung, Seung-Bock;Im, Sang-Kug
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.148-153
    • /
    • 2006
  • This paper analyzes the effect of the energy saving and evaluates the economics using High Efficiency lighting. About 18 percent (17,000GWh) of total power demands in Korea m consumed i]l the lighting field. There isa lot of energy potential that can be saved because the power demand isolwer relatively than the others parts. The existing lighting that its length and electric energy are 32[mm] and 40[w] can alternate with high efficiency lighting which its length and electric energy are 26[mm] and 32[w]. Two Lightings is measuring the illumination and the electric energy and then are analyzed into the effect of the lighting saving by measurement.

  • PDF

Thermal Environment Analysis of a Classroom by CFD Simulation to Determine Optimal Temperature Sensor Position in Ceiling Type Air-Conditioning System (천정형 에어컨 온도센서의 최적 위치 결정을 위한 교실의 CFD 열환경 분석)

  • Li, M.H.;Kim, D.G.;Kum, J.S.;Jeong, S.K.
    • Journal of Power System Engineering
    • /
    • v.10 no.4
    • /
    • pp.43-49
    • /
    • 2006
  • Nowadays, the thermal environments of classrooms are usually adjusted by the ceiling type air-conditioning system with a temperature sensor installed on inlet of an air-conditioner. However, it is not clear that the conventional temperature sensor position is proper to satisfy both thermal comport and energy saving in summer especially. Therefore, this study is aimed at finding out the best position of the temperature sensor on the purpose of the comfort thermal environment and energy saving. The different 5 positions for the temperature sensor are supposed in this paper to analyze thermal environment by CFD. From the analysis through the CFD simulations, the best position of the temperature sensor satisfying for both comfort thermal environment and energy saving is obtained.

  • PDF