• Title/Summary/Keyword: Power-Saving

Search Result 1,284, Processing Time 0.035 seconds

Staged Reconstruction of the Mangled Hand with the Combined Use of Pedicled Groin Flap and Free Wrap Around Flap (광범위 수부 손상에서 서혜부 유경피판과 유리 포장주위피판을 이용한 단계적 무지 재건술)

  • Roh, Young-Hak;Chung, Moon-Sang;Baek, Goo-Hyun;Lee, Young-Ho;Gong, Hyun-Sik;Rhee, Seung-Hwan;Lee, Ye-Hyun
    • Archives of Reconstructive Microsurgery
    • /
    • v.18 no.2
    • /
    • pp.62-66
    • /
    • 2009
  • Purpose: Despite the free tissue transfer using microsurgical technique being the current trend of soft tissue reconstruction of the hand, the pedicled groin flap has the advantage to provide coverage for the mangled hand without necessitating the use of a damaged arterial system and also providing the benefit of saving the arterial system for later free tissue transfer. This report presents the author's experience using pedicled groin flap in four cases of mangled hands with massive bone and soft tissue defects requiring later thumb reconstruction with the free wrap around flap. Materials and methods: The patients' age ranged from 30 to 51 years; three patients were male and one was female. The causes of mangled hand included two machinery crush injuries, one laboratory explosion and one motor vehicle accident. While evaluating the post-operative results, factors like flap survival, complications, stability in opposition, pinch power and 2 point discrimination were taken into account. Results: All massive soft tissue defects of the hands were completely covered with pedicled groin flap successfully. The reconstructed thumb using free wrap around flap did not have any limitation in opposition. There was no occurrence of post-operative infection and all the flaps survived completely. The average pinch power was 70% of the contralateral intact thumb and average 2 point discrimination was 10 mm. Conclusion: The pedicled groin flap for the reconstruction of the massive soft tissue defects of the hand with subsequent reconstruction of the thumb with a wrap around flap is a very useful procedure. The combined use of pedicled groin flap and wrap around flap allows adequate coverage of sizable soft tissue defects and functional thumb opposition in cases of reconstruction of the mangled hands.

  • PDF

Effects of Lettuce Cultivation Using Optical Fiber in Closed Plant Factory (폐쇄형 식물공장내 태양광 파이버를 이용한 상추 재배효과)

  • Lee, Sanggyu;Lee, Jaesu;Won, Jinho
    • Journal of Bio-Environment Control
    • /
    • v.29 no.2
    • /
    • pp.105-109
    • /
    • 2020
  • This study was conducted to the improvement of solar light-based artificial light supply system and effect of lettuce cultivation. The artificial light supply system was consisted of units such as light source, power, system measurement and controller. The light source supply was composed of a solar transmitter and an LED lamp. The power supply consisted of an leakage breaker, SMPS, LED controller and relay. The solar transmitter was made of a quartz optical fiber with optimal light transmission. Artificial light used white lamp among LEDs. System measurement and control consisted of touch screen, Zigbee communication module and light quantity sensor. The results of test confirmed that the LED light is automatically activated when the intensity measured by the light intensity sensor is 200 μmolm-2s-1 or less. Moreover, the leaf length, root length, chlorophyll content and root fresh weight of optical fiber treatment was hight than LED lamp treatment. Therefore, it can be inferred that the energy-saving solar light collector device can be effective in the indoor lettuce production. However, the use of LED lamp is also recommended to assure the availability of sufficient sunlight in cloudy and rainy days.

A Study on the Control System of Maximum Demand Power Using Neural Network and Fuzzy Logic (신경망과 퍼지논리를 이용한 최대수요전력 제어시스템에 관한연구)

  • 조성원
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.9 no.4
    • /
    • pp.420-425
    • /
    • 1999
  • The maximum demand controller is an electrical equipment installed at the consumer side of power system for monitoring the electrical energy consumed during every integrating period and preventing the target maximum demand (MD) being exceeded by disconnecting sheddable loads. By avoiding the peak loads and spreading the energy requirement the controller contributes to maximizing the utility factor of the generator systems. It results in not only saving the energy but also reducing the budget for constructing the natural base facilities by keeping thc number of generating plants ~ninimumT. he conventional MD controllers often bring about the large number of control actions during the every inteyating period and/or undesirable loaddisconnecting operations during the beginning stage of the integrating period. These make the users aviod the MD controllers. In this paper. fuzzy control technique is used to get around the disadvantages of the conventional MD control system. The proposed MD controller consists of the predictor module and the fuzzy MD control module. The proposed forecasting method uses the SOFM neural network model, differently from time series analysis, and thus it has inherent advantages of neural network such as parallel processing, generalization and robustness. The MD fuzzy controller determines the sensitivity of control action based on the time closed to the end of the integrating period and the urgency of the load interrupting action along the predicted demand reaching the target. The experimental results show that the proposed method has more accurate forecastinglcontrol performance than the previous methods.

  • PDF

Improvement of Acid Digestion Method by Microwave for Hazardous Heavy Metal Analysis of Solid Refuse Fuel (고형연료제품의 유해중금속 분석을 위한 마이크로파 산 분해법의 개선)

  • Yang, Won-Seok;Park, Ho-Yeun;Kang, Jun-Gu;Lee, Young-Jin;Lee, Young-Kee;Yoon, Young-Wook;Jeon, Tae-Wan
    • Journal of Korea Society of Waste Management
    • /
    • v.35 no.7
    • /
    • pp.616-626
    • /
    • 2018
  • The quality standards of solid refuse fuel (SRF) define the values for 12 physico-chemical properties, including moisture, lower heating value, and metal compounds, according to Article 20 of the Enforcement Rules of the Act on Resource Saving and Recycling Promotion. These parameters are evaluated via various SRF Quality Test Methods, but problems related to the heavy metal content have been observed in the microwave acid digestion method. Therefore, these methods and their applicability need improvement. In this study, the appropriate testing conditions were derived by varying the parameters of microwave acid digestion, such as microwave power and pre-treatment time. The pre-treatment of SRF as a function of the microwave power revealed an incomplete decomposition of the sample at 600 W, and the heavy metal content analysis was difficult to perform under 9 mL of nitric acid and 3 mL of hydrochloric acid. The experiments with the reference materials under nitric acid at 600 W lasted 30 minutes, and 1,000 W for 20 or 30 minutes were considered optimal conditions. The results confirmed that a mixture of SRF and an acid would take about 20 minutes to reach $180^{\circ}C$, requiring at least 30 minutes of pre-treatment. The accuracy was within 30% of the standard deviation, with a precision of 70 ~ 130% of the heavy metal recovery rate. By applying these conditions to SRF, the results for each condition were not significantly different and the heavy metal standards for As, Pb, Cd, and Cr were satisfied.

Classification Method of Multi-State Appliances in Non-intrusive Load Monitoring Environment based on Gramian Angular Field (Gramian angular field 기반 비간섭 부하 모니터링 환경에서의 다중 상태 가전기기 분류 기법)

  • Seon, Joon-Ho;Sun, Young-Ghyu;Kim, Soo-Hyun;Kyeong, Chanuk;Sim, Issac;Lee, Heung-Jae;Kim, Jin-Young
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.3
    • /
    • pp.183-191
    • /
    • 2021
  • Non-intrusive load monitoring is a technology that can be used for predicting and classifying the type of appliances through real-time monitoring of user power consumption, and it has recently got interested as a means of energy-saving. In this paper, we propose a system for classifying appliances from user consumption data by combining GAF(Gramian angular field) technique that can be used for converting one-dimensional data to the two-dimensional matrix with convolutional neural networks. We use REDD(residential energy disaggregation dataset) that is the public appliances power data and confirm the classification accuracy of the GASF(Gramian angular summation field) and GADF(Gramian angular difference field). Simulation results show that both models showed 94% accuracy on appliances with binary-state(on/off) and that GASF showed 93.5% accuracy that is 3% higher than GADF on appliances with multi-state. In later studies, we plan to increase the dataset and optimize the model to improve accuracy and speed.

CARIES PREDICTION MODEL USING LASER FLUORESCENCE (레이저 형광법을 이용한 우식유발 예측모형)

  • Lee, Sang-Ho;Lee, Chang-Seop;Jeong, Yeon-Hwa
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.1
    • /
    • pp.16-24
    • /
    • 2001
  • The purpose of this study was to evaluate the specificity, sensitivity, and diagnostic power of caries activity test using laser fluorescence. The subjects of this study were 50 children of $7\sim9$ years old. Fluorescence from initial carious lesion of teeth illuminated by an argon laser(480nm) was observed and photographed with barrier filter. Visual examination for the dDfFtT rate and Streptococcus mutans colony counting was done to evaluate correlation with caries activity test using laser fluorescence. Data analysis was accomplished by Axelsson's method. The results from the present study can be summarized as follows: 1. There was positive correlation $(\gamma=0.48)$ between laser fluorescence test and Streptococcus mutans count. And also positive correlation $(\gamma=0.39)$ exists between laser fluorescence test and dDfFtT rate (P<0.01). 2. Positive correlation $(\gamma=0.27)$ between Streptococcus mutans colony count and dDfFtT rate was found(P<0.05). 3. When dDfFtT rate was defined to standard testing method, the specificity, senstivity, and diagnostic power of laser fluorescence test were 44.4%, 85.7%, and 87.8%. 4. When dDfFtT rate was defined to standard testing method, the specificity, senstivity, and diagnostic power of S. mutans colony counting were 77.8%, 92.9%, 84.8%. 5. When S. mutans colony counting was defined to standard testing method, sensitivity, specificity and diagnostic power of laser fluorescence test were 40.0%, 84.8%, 95.1%. In regard to above results, laser fluorescence test considered to be accurate and reliable method for determining caries activity because of it's close relationship with caries susceptibility test and caries experience measurements. And it was also considered to be practical because it would be simple, inexpensive, and time saving method.

  • PDF

Application Effect of Heating Energy Saving Package on Venlo Type Glasshouse of Paprika Cultivation (파프리카 재배 벤로형 유리온실에서 난방에너지 절감 패키지 기술 적용효과)

  • Kwon, Jin Kyung;Jeon, Jong Gil;Kim, Seung Hee;Kim, Hyung Gweon
    • Journal of Bio-Environment Control
    • /
    • v.25 no.4
    • /
    • pp.225-231
    • /
    • 2016
  • Glasshouse heating package technologies to improve energy usage efficiency in winter were developed. Heating package was composed of the ground water source heat pump with heating capacity of 105kW, the aluminum multi-layer thermal curtain with six layers of different materials and the root zone local heater with XL pipes of ${\phi}20mm$. Venlo type glasshouse($461m^2$) with the heating package was compared with the same type and area control glasshouse with the light oil boiler, the usual non-woven fabric thermal curtain with respect to the glasshouse inside temperature, relative humidity, crop growth, and heating energy consumption. The results of test in paprika cultivation glasshouses showed that the air temperature inside glasshouse with aluminum multi-layer thermal curtain was maintained $2.2^{\circ}C$ higher than that of control glasshouse in un-heating night time and the temperature in bed with root zone local heating was $4.7^{\circ}C$ higher than that in bed without local heating. Average heating coefficient of performance(COP) of the ground water source heat pump used in paprika cultivation was 3.7 and the glasshouse inside temperature was maintained at $21^{\circ}C$ of heating set up temperature. The heating energy consumptions per 10a were measured at 14,071L of light oil and 364kWh of electric power for the control glasshouse and 35,082kWh for the glasshouse applied heating package. As results, the heating cost of the glasshouse applied heating package was 87 percent lower than that of control glasshouse. The growths of paprika in glasshouses of control and applied heating package did not show any significant difference.

Energy Saving Effect for High Bed Strawberry Using a Crown Heating System (고설 딸기 관부 난방시스템의 에너지 절감 효과)

  • Moon, Jong Pil;Park, Seok Ho;Kwon, Jin Kyung;Kang, Youn Koo;Lee, Jae Han;Kim, Hyung Gweon
    • Journal of Bio-Environment Control
    • /
    • v.28 no.4
    • /
    • pp.420-428
    • /
    • 2019
  • This study is the heating energy saving test of the high-bed strawberry crown heating system. The system consists of electric hot water boiler, thermal storage tank, circulation pump, crown heating pipe(white low density polyethylene, diameter 16mm) and a temperature control panel. For crown heating, the hot water pipe was installed as close as possible to the crown part after planting the seedlings and the pipe position was fixed with a horticultural fixing pin. In the local heating type, hot water at $20{\sim}23^{\circ}C$ is stored in the themal tank by using an electric hot water boiler, and crown spot is partially heated at the setting temperature of $13{\sim}15^{\circ}C$ by turning on/off the circulation pump using a temperature sensor for controlling the hot water circulation pump which was installed at the very close to crown of strawberry. The treatment of test zone consisted of space heating $4^{\circ}C$ + crown heating(treatment 1), space heating $8^{\circ}C$(control), space heating $6^{\circ}C$ + crown heating(treatment 2). And strawberries were planted in the number of 980 for each treatment. The heating energy consumption was compared between November 8, 2017 and March 30, 2018. Accumulated power consumption is converted to integrated kerosene consumption. The converted kerosene consumption is 1,320L(100%) for space $8^{\circ}C$ heating, 928L(70.3%) for space $4^{\circ}C$ + crown heating, 1,161L($88^{\circ}C$) for space $6^{\circ}C$ + crown heating). It was analyzed that space $4^{\circ}C$ + pipe heating and space $6^{\circ}C$ + crown heating save heating energy of 29.7% and 12% respectively compared to $8^{\circ}C$ space heating(control).

DEVELOPMENT OF HIGH SENSITIVE MODEL OF CARIES ACTIVITY TEST FOR EARLY DIAGNOSIS OF DENTAL CARIES (치아우식증의 조기진단을 위한 고감도 우식활성검사 모형개발)

  • Lee, Sang-Ho;Lee, Chang-Seop
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.1
    • /
    • pp.169-179
    • /
    • 2000
  • The purpose of this study is to develop the system which convert the optical difference of teeth texture between intact enamel and incipient caries lesion into shade difference by laser fluorescence and to develop new and simple caries activity test using laser fluorescence. The experimental design of this study consists of three parts. In first part, a new method for the in vitro assessment of changes in initial enamel caries lesion of Bovine teeth using laser fluorescence is tested. In second part, in vivo assessment undertaken. Number of teeth which showed incipient carious lesion on buccal surface examined by laser fluorescence was compared with the caries activity test of $Cariescreen^{(R)}$ test and other oral environmental test of dDfFtT. In third part, new caries activity test measured by laser fluorescence was developed on the basis of above results and evaluated the sensitivity, specificity, and diagnostic power. Optical density measured by laser fluorescence was increased as increasing the depth of incipient carious lesion and showed high correlation$(\gamma=0.7015)$ with lesion depth. Optical density showed direct proportion to lesion depth. Linear equation was obtained between the optical density and the lesion depth by regression analysis. The result of caries activity test with laser fluorescence showed high correlation with those of $Cariescreen^{(R)}$ test and dDfFtT examination. Caries activity test with laser fluorescence showed 48% of sensitivity, 52% of specificity, and 45% of diagnostic power on the basis of dDfFtT examination, and also showed 48% of sensitivity, 51% of specificity, and 36% of diagnostic power on the basis of $Cariescreen^{(R)}$ test. In regard above result, caries activity test with laser fluorescence considered to be reliable for caries activity test compared with other oral environmental test. and it was also considered to be practical because it would be simple, inexpensive, and time saving method.

  • PDF

Variation of Indoor Air Temperature by using Hot Water Piping in Greenhouse (온수배관에 의한 온실 내부의 온도변화)

  • Yoon, Yong-Cheol;Shin, Yik-Soo;Bae, Seoung-Beom;Kim, Hyeon-Tae;Choi, Jin-Sik;Suh, Won-Myung
    • Journal of agriculture & life science
    • /
    • v.46 no.2
    • /
    • pp.179-190
    • /
    • 2012
  • This study was performed to obtain a heat saving effect and enhance the efficiency of a greenhouse by using a hot water piping in order to minimize the operating costs of a greenhouse as oil prices continue to rise. This method also reduces the likelihood of accidents caused by snowdrifts in regions with heavy snowfall. In general, the experimental plot was $2.0{\sim}6.0^{\circ}C$ higher than the control plot. When the skylight felt was opened, the minimum temperature was in the range of $3.0{\sim}12.0^{\circ}C$. Therefore, we judged that damage caused by snowdrifts may be prevented partly by active heating. The temperature difference inside of the greenhouse by height was insignificant. The maximum heating load of the greenhouse according to crop was respectively about $37,000kcal{\cdot}h^{-1}$ and $41,700kcal{\cdot}h^{-1}$. During the experiment, the heat value of each designed temperature in the range of the minimum ambient temperature $-11.9{\sim}4.0^{\circ}C$ was about 95,000~322,000 kcal and it was in the range of $6,050{\sim}20,900kcal{\cdot}h^{-1}$. If it is compared with the maximum heating load, it can be shown that about 15~56% of the heating energy can be supplied. The total heat value and the amount of power consumption were 2,629,025 kcal and 677.3 kWh respectively during the experiment. If it is heated with diesel, a fossil fuel, the consumption during the experiment was 291 L and the cost was 331,700won. Total cost of using electric power was about 24,400 won and it is shown that it is about 7.5% of the cost of diesel consumption. Also, if the total amount of power consumption is converted into energy, it is approximately 582,200 kcal and the energy was just about 22% of the total heat value.