• Title/Summary/Keyword: Power-Saving

Search Result 1,284, Processing Time 0.035 seconds

An Energy-efficient LED Lighting Control Scheme with Provision of User Illumination Requirement (사용자 요구조도 보장 에너지 효율적 LED 조명 제어 기법)

  • Kim, Yong-Ho;Lee, Kwon-Hyung;Chang, Kap-Seok;Choi, Yong-Hoon;Kim, Hoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.11B
    • /
    • pp.1383-1388
    • /
    • 2011
  • Due to many recent activities on enforcement of the intensified environmental regulation such as the policies of curbing the greenhouse gas and the Restriction of Hazardous Substances (RoHS), the usage of Light emitting diode (LED) has been rapidly increased and energy efficient management of LED light system is regarded as an important technology to enhance the energy efficiency. In this paper, we propose an energy-efficient control scheme of LED light, being composed of multiple light sources. The proposed scheme controls the intensity of LED light source to minimize the total intensity while providing the quality of lighting service. The intensity of light is assumed to be proportional to power consumption, thus the objective is to minimize the total power consumption. A linear programming problem is formulated to find the optimal intensity of each light source and procedure to apply the proposed scheme in the real system is suggested. The performance evaluation results elucidate that the proposed scheme achieves over 20% improvement in power consumption of light intensity in comparison with the conventional dimming control scheme.

A Study on the Optimization of District Heating and Cooling Facilities (지역냉난방사업의 설비 최적화에 관한 연구)

  • Kim, Jin Hyung;Choi, Byung Ryeal
    • Environmental and Resource Economics Review
    • /
    • v.15 no.3
    • /
    • pp.505-530
    • /
    • 2006
  • For the district heating and cooling business, it is required to install energy-saving facilities using energy from waste and land fill gases such as combined heat and power(CHP). The current issues that this business faces can be summarized as below: which facilities including CHP can be economically introduced and how much of their capacities should be. Most of such issues are clearly related to the optimal plant design of the district heating and cooling business, and the prices of energy services such as heating and cooling energy, and electricity. The purpose of this study is to establish linear program model of least cost function and to practice the empirical test on a assumed district heating and cooling business area. The model could choose the optimal type of energy-producing facilities among various kinds available such as CHP's, absorption chillers, the ice-storage system, etc. CHP with the flexible heat and power ratio is also in the set of available technologies. And the model show us the optimal ration of heat producing facilities between CHP and historical heat only boiler in the service area. Some implications of this study are summarized as below. Firms may utilize this model as a tool for the analysis of their optimal size of the facilities and operation. Also, the government may refer the results to regulate resonable size of business.

  • PDF

A Fast Scattered Pilot Synchronization Algorithm for DVB-H receiver modem (DVB-H 수신기 모뎀을 위한 고속 분산 파일럿 동기 알고리즘)

  • Um Jung-Sun;Do Joo-Hyun;Lee Hyun;Choi Hyung-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.11A
    • /
    • pp.1081-1091
    • /
    • 2005
  • Unlike conventional DVB-T transmission with the streaming method, DVB-H system based on the IPDC(IP Data Casting) method uses Time-slicing scheme to achieve the maximization of portability by reducing the power consumption of a receiver. To enhance the power efficiency of the receiver, Time-slicing scheme controls the receiver operation to perform only for corresponding burst in specific time slot. The additional power saving can also be achieved by reducing the required time for synchronization. In this paper, we propose a fast scattered pilot synchronization algorithm, which detects the pilot pattern of currently received OFDM symbol. The proposed scheme is based on the correlation between the adjacent subcarriers of potential scattered pilot position in two consecutively received OFDM symbols. Therefore, it can reduce the time for the scattered pilot synchronization within two symbols as com-pared with the conventional method used for DVB-T. And the proposed algorithm has better performance than the two schemes proposed by Nokia for DVB-H and the method using correlation with reference signal. Extensive com-puter simulation is performed based on ETSI EN300 744 ETSI and performance results show that the proposed algorithm has more efficient and stable operation than the conventional schemes.

A Study on Time Synchronization Protocol to Cover Efficient Power Management in Ubiquitous Sensor Network (유비쿼터스 센서 네트워크를 위한 효율적인 시간 동기화 프로토콜 연구)

  • Shin, Moon-Sun;Jeong, Kyeong-Ja;Lee, Myong-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.3
    • /
    • pp.896-905
    • /
    • 2010
  • The sensor networks can be used attractively for various application areas. Time synchronization is important for any Ubiquitous Sensor Networks (USN) systems. USN makes extensive use of synchronized time in many contexts for data fusion. However existing time synchronization protocols are available only for homogeneous sensor nodes of USN. It needs to be extended or redesigned in order to apply to the USN with heterogeneous sensor nodes. Because heterogeneous sensor nodes have different clock sources with the SinkNode of USN, it is impossible to be synchronized global time. In addition, energy efficiency is one of the most significant factors to influence the design of sensor networks, as sensor nodes are limited in power, computational capacity, and memory. In this paper, we propose specific time synchronization based on master-slave topology for the global time synchronization of USN with heterogeneous sensor nodes. The time synchronization master nodes are always able to be synchronized with the SinkNode. Then time synchronization master nodes enable time synchronization slave nodes to be synchronized sleep periods. The proposed master-slave time synchronization for heterogeneous sensor nodes of USN is also helpful for power saving by maintaining maximum sleep time.

Development of Digital Solder Station Based on PID Controller (PID 제어기를 이용한 전기인두기의 온도 제어 시스템 개발)

  • Oh, Kab-Suk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.3
    • /
    • pp.866-872
    • /
    • 2010
  • In this paper, we developed a digital soldering station based on PID controller, which supply stable power by controlling the current of heater of soldering iron. The proposed system designed PID controller to converge quickly to the set up temperature by user, and regain the lost of heat by external factors quickly. PID controller, designed by Ziegler-Nichols' tuning method, decides triac's trigger timing using setting temperature and present temperature to control the phase of AC 24V power that supply to the heater. Also, we give the function that shows present temperature and setting temperature of iron, and working time by graphic LCD. And during the rest time, we decided the power saving and extension of iron tip by dropping to the optimal temperature. Two experiments had implemented in $25^{\circ}C$ laboratory to confirm the performance of proposed method. The first experiment took 12sec, 13sec, 16sec, 18sec, reaching to $200^{\circ}C$, $300^{\circ}C$, $400^{\circ}C$, $480^{\circ}C$ respectively which result showed shorten of rising time than previous method. In the loading experiment of $300^{\circ}C$, $400^{\circ}C$, $480^{\circ}C$ steady state showed temperature drop of $3.8^{\circ}C$, $4.1^{\circ}C$, $4.5^{\circ}C$ which result showed the low temperature deviation than previous method.

Studies on Determinant Factors of SCM Performance: From the Supplier Perspective (SCM 성과 결정요인에 관한 통합적 연구: 공급업체 관점으로)

  • Park, Kwang-Oh;Chang, Hwal-Sik
    • Asia pacific journal of information systems
    • /
    • v.21 no.1
    • /
    • pp.1-27
    • /
    • 2011
  • In an attempt to cope with widespread, dynamic, and accelerating changes in both internal and external business environments, companies often utilize information technologies such as SCM(Supply Chain Management). To date, SCM research has mainly focused on the effects of dynamic factors on SCM success and emphasized adoption strategies and critical success factors. Consequently, the effects of more static factors such as interdependency between SCM partners have been largely ignored. The purpose of this study, therefore, is to examine the effects of both dynamic and static factors on SCM performance by controlling for information quality and partnership quality. The five factors examined in this study include innovative ness, mutual dependency, quality of information, partnership quality, and SCM performance. All factors were examined from the perspective of part suppliers, except the mutual dependency which was examined from two aspects: supplier's dependency on customer and customer's dependency on supplier. Data was collected through five hundred survey questionnaires distributed to the part supplier companies that have implemented SCM systems for at least one year. As a result, a total of 170 valid responses were obtained. A structural equation research model was fitted using SAS 9.1.3 and SMART-PLS 2.0. The results of this study can be summarized as follows. First, innovativeness positively affected SCM information quality. SCM partnership quality, and ultimately SCM performance. The path coefficient between innovativeness and information quality was 0.387, with a t-value of 3.528. Innovativeness also had a positively direct effect on partnership quality. The path coefficient was 0.351 with a t-value of 3.366. The total effect of innovativeness on partnership quality was significant, although its indirect effect on partnership quality by altering information quality was negligible. The total indirect effect of innovativeness on SCM performance by affecting information quality and partnership quality was significant with a p-value of 0.014. Innovativeness played an important role in determining SCM performance. Second, mutual dependency showed no significant effect on SCM information quality. This result contradicts the earlier assertion that the more dependent two companies are, the more accurate and timely the information they exchange ought to be. This study showed that this may not be the case; a partner may provide information of poor quality even when it is strongly dependent on the other. Mutual dependency showed significant effect on partnership quality. However, when the mutual dependency perceived by suppliers was divided into two parts, one being a supplier's dependency on its customer company and the other being a customer's dependency on the supplier, the latter showed a significant impact on the perceived SCM partnership quality. This result indicates that a customer company can hardly improve the partnership quality perceived by suppliers by making them more dependent. It improves only when the suppliers perceive that their partners, typically having more bargaining power, are more dependent on them. The overall effect of mutual dependency of any kind on SCM performance, however, was not significant. Although mutual dependency has been mentioned as an important static factor influencing almost every aspect of cooperation on a supply chain, its influences may not be as significant as it was initially perceived to be. Third, the correlation between information quality and partnership quality was 0.448 with a p-value of less than 0.001. Information quality had a path coefficient of 0.256 to partnership quality with a t-value of 2.940. The quality of information exchanged between partners may have an impact on their partnership quality. Fourth, information quality also had a significant impact on SCM performance with a path coefficient of 0.325 with a t-value of 3.611. In this study, SCM performance was divided into four categories: product quality, cost saving, service quality, and order fulfillment. Information quality has Significant impacts on product quality, cost saving and service quality, but not on order fulfillment. Fifth, partnership quality, as expected, had a significant impact on SCM performance. The path coefficient was 0.403 with a t-value of 3.539. Partnership quality, like information quality, had positive impacts on product quality, cost saving and service quality, but showed no impact on order fulfillment. It seemed that order fulfillment is the hardest category of performance that SCM can satisfy. One major limitation of this study is that it surveyed only the suppliers. To better understand the dual aspects of SCM, it is important to survey both suppliers and the assemblers, especially in pairs. This research, to our best knowledge, was the first attempt to study the level of dependency between the two groups by measuring the dual aspects of SCM and studying mutual dependency from the categories of suppliers and assemblers each.. In the future, a more comprehensive and precise measurement of SCM characteristics needs to be achieved by examining from both the supplier's and assembler's perspectives.

Analysis and Design of Profiling Adaptor for XML based Energy Storage System (XML 기반의 에너지 저장용 프로파일 어댑터 분석 및 설계)

  • Woo, Yongje;Park, Jaehong;Kang, Mingoo;Kwon, Kiwon
    • Journal of Internet Computing and Services
    • /
    • v.16 no.5
    • /
    • pp.29-38
    • /
    • 2015
  • The Energy Storage System stores electricity for later use. This system can store electricity from legacy electric power systems or renewable energy systems into a battery device when demand is low. When there is high electricity demand, it uses the electricity previously stored and enables efficient energy usage and stable operation of the electric power system. It increases the energy usage efficiency, stabilizes the power supply system, and increases the utilization of renewable energy. The recent increase in the global interest for efficient energy consumption has increased the need for an energy storage system that can satisfy both the consumers' demand for stable power supply and the suppliers' demand for power demand normalization. In general, an energy storage system consists of a Power Conditioning System, a Battery Management System, a battery cell and peripheral devices. The specifications of the subsystems that form the energy storage system are manufacturer dependent. Since the core component interfaces are not standardized, there are difficulties in forming and operating the energy storage system. In this paper, the design of the profile structure for energy storage system and realization of private profiling system for energy storage system is presented. The profiling system accommodates diverse component settings that are manufacturer dependent and information needed for effective operation. The settings and operation information of various PCSs, BMSs, battery cells, and other peripheral device are analyzed to define profile specification and structure. A profile adapter software that can be applied to energy storage system is designed and implemented. The profiles for energy storage system generated by the profile authoring tool consist of a settings profile and operation profile. Setting profile consists of configuration information for energy device what composes energy saving system. To be more specific, setting profile has three parts of category as information for electric control module, sub system, and interface for communication between electric devices. Operation profile includes information in relation to the method in which controls Energy Storage system. The profiles are based on standard XML specification to accommodate future extensions. The profile system has been verified by applying it to an energy storage system and testing charge and discharge operations.

A Study on the Tele-Controller System of Navigational Aids Using CDMA Communication (CDMA 통신을 이용한 항로표지의 원격관리시스템에 관한 연구)

  • Jeon, Joong-Sung;Oh, Jin-Seok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.8
    • /
    • pp.1254-1260
    • /
    • 2009
  • CDMA tele-Controller system is designed with a low power consumption 8 bit microcontroller, ATmega 2560. ATmega 2560 microcontroller consists of 4 UART (Universal asynchronous receiver/transmitter) ports, 4 kbytes EEPROM, 256 kbytes flash memory, 4 kbytes SRAM. 4 URAT is used for CDMA modem, communication for GPS module, EEPROM is used for saving a configuration for program running, a flash memory of 256 kbytes is used for storing a F/W(Firm Ware), and SRAM is used for stack, storing memory of global variables while program running. We have tested the communication distance between the coast station and sea by the fabricated control board using 800 MHz CDMA modem and GPS module, which is building for the navigational aid management system by remote control. As a results, the receiving signal strength is above -80 dBm, and then the characteristics of the control board implemented more than 10 km in the distance of the communication.

Adaptive Filtering for Aggregation in Sensor Networks (센서 네트워크에서 집계연산을 위한 적응적 필터링)

  • Park, No-Joon;Hyun, Dong-Joon;Kim, Myoung-Ho
    • Journal of KIISE:Databases
    • /
    • v.32 no.4
    • /
    • pp.372-382
    • /
    • 2005
  • Aggregation such as computing an average value of data measured in each sensor commonly occurs in many applications of sensor networks. Since sensor networks consist of low-cost nodes with limited battery power, reducing energy consumption must be considered in order to achieve a long network lifetime. Reducing the amount of messages exchanged is the most important for saving energy. Earlier work has demonstrated the effectiveness of in-network data aggregation and data filtering for minimizing the amount of messages in sensor networks. In this paper, we propose an adaptive error adjustment scheme that is simpler, more effective and efficient than previous work. The proposed scheme is based on self-adjustment in each sensor node. We show through various experiments that our scheme reduces the network traffic significantly, and performs better than existing methods.

Comparison of detergency effectiveness by the type of household washer, detergent and soil - Focused on detergency, rinsing, fabric damage and tanglement - (가정용 세탁기, 세제 및 오염의 종류별 세탁 성능 비교 - 세탁성, 헹굼성, 섬유손상도, 엉킴도를 중심으로 -)

  • Piao, Shujing;Park, Myung-Ja
    • The Research Journal of the Costume Culture
    • /
    • v.21 no.6
    • /
    • pp.950-960
    • /
    • 2013
  • The purpose of this research is to provide accurate information of household washers and detergents for consumers, so that help the producers who make washing machine and detergent to get basic material and also help consumers to choose washing machine. Experiment was proceed with two type of washers to compare energy consumption, washing performance, rinsing effectiveness further, damage caused by entanglement of laundry and fabric was assessed. Detergent P and T were used to compare the performance related to differences of ingredients of detergent. Soiled fabrics of EMPA 108 set were used to evaluate performance of washing by different types of contamination. A summary of experimental results are : First, for the consumption of water, drum-type washer consumed 53% less than pulsator-type washer. On the other hand, the washing time was almost similar for both these machines, but pulsator-type washer showed shorter progress, implying that power saving was more efficient in this case. Second, the drum-type washer showed better performance for contamination with all types of detergent, but the pulsator-type washer showed better rinsing performance. Third, the drum-type washer performed less data of tangle level and fabric damage. Fourth, detergent "P" exhibited better washing performance than did detergent "T", regardless of the type of soil. And with no limit of detergent variety, water-soluble protein soil showed high removal rate, liposoluble soil especially pigment was hardly removed.