• Title/Summary/Keyword: Power-Free

Search Result 2,151, Processing Time 0.027 seconds

Free vibration analysis of power-law and sigmoidal sandwich FG plates using refined zigzag theory

  • Aman Garg;Simmi Gupta;Hanuman D. Chalak;Mohamed-Ouejdi Belarbi;Abdelouahed Tounsi;Li Li;A.M. Zenkour
    • Advances in materials Research
    • /
    • v.12 no.1
    • /
    • pp.43-65
    • /
    • 2023
  • Free vibration analysis of power law and sigmoidal sandwich plates made up of functionally graded materials (FGMs) has been carried out using finite element based higher-order zigzag theory. The present model satisfies all-important conditions such as transverse shear stress-free conditions at the plate's top and bottom surface along with continuity condition for transverse stresses at the interface. A Nine-noded C0 finite element having eleven degrees of freedom per node is used during the study. The present model is free from the requirement of any penalty function or post-processing technique and hence is computationally efficient. The present model's effectiveness is demonstrated by comparing the present results with available results in the literature. Several new results have been proposed in the present work, which will serve as a benchmark for future works. It has been observed that the material variation law, power-law exponent, skew angle, and boundary condition of the plate widely determines the free vibration behavior of sandwich functionally graded (FG) plate.

Power System Stabilizer using the Free Model

  • Kim, Ho-Chan;Oh, Seong-Bo;Lee, Kwang-Yeon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.139.3-139
    • /
    • 2001
  • The free-model concept is introduced as an alternative intelligent system technique to design a controller with input and output data only. The idea of free model comes from the Taylor series approximation, where an output can be estimated when such data as position, velocity, and acceleration are known. The parameters in the free model can be estimated using the input-output data and a controller can be designed based on the free model. The free model thus developed is shown to be controllable, observable, and robust. The accuracy of the free-model approximation can be improved by increasing the observation window and the order of the free model. The LQR method is applied to the free model to design power system stabilizers ...

  • PDF

미래형 대형풍력발전기 개발 추세 (Europe 지역의 Case Study)

  • 오철수
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1998.05a
    • /
    • pp.271-277
    • /
    • 1998
  • 1. Why Wind Power\ulcorner Advantages of Wind Energy : free cost, non-pollutant, free waste large unit is possible Disadvantages : intermittent of energy density limited sites Unit Capacity of various Power Plant Solar PP : 10 - 500㎾ Wind PP : 200 - 2000 ㎾ Nuclear PP 700 - 1000 MW Installation Cost of Power Plants Nuclear PP : $ 2,500/㎾ Solar PP : $ 6,000/㎾ Wind PP : $ 1.000 /kw.

  • PDF

Flicker-Free Visible Light Communication System Using Byte-Inverted Transmission (바이트반전 전송방식을 이용한 플리커 방지 가시광통신시스템)

  • Lee, Seong-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.408-413
    • /
    • 2017
  • In this paper, we newly developed a byte-inverted transmission method for flicker-free visible light communication (VLC). The VLC transmitter sends original data in the former half period of the clock, and inverted data and in the latter half period of the clock. The VLC receiver receives the original data in the in the former half period of the clock. In this system, we used 480Hz clock that was generated from the 60Hz power line. The average optical power of the LED array in the transmitter is constant, thus flicker-free, in the observation time longer than the period of the clock that is about 2ms. This period is shorter than the maximum flickering time period (MFTP) of 5ms that is generally considered to be safe. This configuration is very useful in constructing indoor wireless sensor networks using LED light because it is flicker-free and does not require additional transmission channel for clock transmission.

A Study on Flicker Free LED Driver for Dimming MR16 Electronic Transformer (조광기용 MR16 안정기 호환 Flicker Free LED 구동회로 연구)

  • Kim, Taek-Woo;Yeom, Bong-Ho;Lee, Kang-Hee;Lee, Dong-Ryul;Kim, Ju-Rae;Hong, Sung-Soo
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.161-162
    • /
    • 2013
  • LED(Light Emitting Diode)는 친환경적 특성, 긴 수명, 우수한 효율, 빠른 응답 속도 등의 장점이 있어 최근 기존의 백열 전등 및 형광등을 대체하는 조명 수단으로 각광받고 있다. 기존의 LED구동회로를 조광기용 MR16안정기에 연결할 경우 안정기와 조광기의 오동작으로 인해 Flicker 현상이 발생되고 선형적인 Dimming이 불가능하다. 그러므로 본 논문에서는 MR16 안정기와 조광기용 MR16안정기를 호환하는 Flicker Free LED 구동회로를 제안한다. 또한 LED구동회로의 원리와 Dimming에 따른 LED전류제어기법 원리를 설명하고 모의실험 및 시작품 제작을 통해 제안 회로의 타당성을 검증한다.

  • PDF

Safety assessment of nuclear fuel reprocessing plant under the free drop impact of spent fuel cask and fuel assembly part I: Large-scale model test and finite element model validation

  • Li, Z.C.;Yang, Y.H.;Dong, Z.F.;Huang, T.;Wu, H.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.8
    • /
    • pp.2682-2695
    • /
    • 2021
  • This paper aims to evaluate the structural dynamic responses and damage/failure of the nuclear fuel reprocessing plant under the free drop impact of spent fuel cask (SFC) and fuel assembly (FA) during the on-site transportation. At the present Part I of this paper, the large-scale SFC model free drop test and the corresponding numerical simulations are performed. Firstly, a composite target which is composed of the protective structure, i.e., a thin RC plate (representing the inverted U-shaped slab in the loading shaft) and/or an autoclaved aerated concrete (AAC) blocks sacrificial layer, as well as a thick RC plate (representing the bottom slab in the loading shaft) is designed and fabricated. Then, based on the large dropping tower, the free drop test of large-scale SFC model with the mass of 3 t is carried out from the height of 7 m-11 m. It indicates that the bottom slab in the loading shaft could not resist the free drop impact of SFC. The composite protective structure can effectively reduce the damage and vibrations of the bottom slab, and the inverted U-shaped slab could relieve the damage of the AAC blocks layer dramatically. Furthermore, based on the finite element (FE) program LS-DYNA, the corresponding refined numerical simulations are performed. By comparing the experimental and numerical damage and vibration accelerations of the composite structures, the present adopted numerical algorithms, constitutive models and parameters are validated, which will be applied in the further assessment of drop impact effects of full-scale SFC and FA on prototype nuclear fuel reprocessing plant in the next Part II of this paper.

A Comparative Study of the Fatigue Behavior of SnAgCu and SnPb Solder Joints (무연솔더(SnAgCu)와 유연솔더(SnPb)의 피로 수명 비교 연구)

  • Kim, Il-Ho;Park, Tae-Sang;Lee, Soon-Bok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.12
    • /
    • pp.1856-1863
    • /
    • 2004
  • In the last 50 years, lead-contained solder materials have been the most popular interconnect materials used in the electronics industry. Recently, lead-free solders are about to replace lead-contained solders for preventing environmental pollutions. However, the reliability of lead-free solders is not yet satisfactory. Several researchers reported that lead-contained solders have a good fatigue property. The others published that the lead-free solders have a longer thermal fatigue life. In this paper, the reason for the contradictory results published on the estimation of fatigue life of lead-free solder is investigated. In the present study, fatigue behavior of 63Sn37Pb, and two types of lead-free solder joints were compared using pseudo-power cycling testing method, which provides more realistic load cycling than chamber cycling method does. Pseudo-power cycling test was performed in various temperature ranges to evaluating the shear strain effect. A nonlinear finite element model was used to simulate the thermally induced visco-plastic deformation of solder ball joint in BGA packages. It was found that lead-free solder joints have a good fatigue property in the small temperature range condition. That condition induce small strain amplitude. However in the large temperature range condition, lead-contained solder joints have a longer fatigue life.

Torsional Free Vibration Analysis of Propulsion Shafting of Training Ship SAEDONGBAEK by Sylvester-Transfer Stiffness Coefficient Mehtod (실베스터-전달강성계수법에 의한 실습선 새동백호 추진축계의 비틀림 자유진동 해석)

  • Kim, Myung-Jun;Wang, Woo-Gyeong;Yeo, Dong-Jun;Choi, Myung-Soo
    • Journal of Power System Engineering
    • /
    • v.22 no.6
    • /
    • pp.11-19
    • /
    • 2018
  • In this study, the authors examine the propulsion shafting of the training ship SAEDONGBAEK and perform modeling to analyze the torsional free vibration of the shafting. In this paper, the computational algorithm for analyzing the torsional free vibration of the shafting with a reduction gear is formulated by the sylvester-transfer stiffness coefficient method (S-TSCM) that is a recently developed and a powerful method in free vibration analysis. According to the state of the controllable pitch propeller of the shafting and the temperature of the elastic coupling, the torsional free vibration of the shafting is performed by the S-TSCM. The authors examine the changes of the natural frequencies and natural modes which are the results of the torsional free vibration analysis of the shafting.

Fabrication of Bi System Superconducting Films on Cu Tape with Melt-Quenched Cu-free Materials (Cu-free 비정질체를 이용한 동 테이프 위의 Bi계 초전도 후막 제조)

  • Sung, Tae-Hyun;Han, Sang-Chul;Han, Young-Hee;Lee, Jun-Seong;Kim, Sang-Joon
    • 한국초전도학회:학술대회논문집
    • /
    • v.9
    • /
    • pp.315-318
    • /
    • 1999
  • Bi$_{2}Sr_{2}CaCu_{2}O_{\delta}$ superconducting films were rapidly fabricated on copper tape by liquid reaction between a Cu-free precursor and Cu tape (LiReac-PreCu) method. Those thick films were well oriented along the c-axis. The precursor was made by melt-quenched technology using twin roller. The melt-quenched films were transparent and glossy yellow in appearance. These films which were the compostion of Bi$_2SrCaO_y$, Bi$_3Sr_2CaO_z$ were placed on copper tape and then heated at various temperatures for several minutes in air. They were analyzed using X-ray powder diffraction, SEM, a DC four-probe method. The mechanism of superconducting phase formation . from the melt-quenched precursor on Cu tape was studied

  • PDF

Design of Active Power Factor Corrector for Low Power Supply by Loss Free Resistor Concept (무손실 저항개념을 이용한 저전력 전원설비용 능동 역률보정기의 설계)

  • 임영철;정영국;최찬학;나석환;이건식;장영학
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.7 no.1
    • /
    • pp.30-36
    • /
    • 1993
  • A simple discontinuous conduction mode(DCM) flyback type active power factor corrector for low power supply resents an effective resistive load to its power input. It is therefore well suited as an inexpensive high power factor rectifier for office equipment. An equivalent circuit model for the Active Power Factor Corrector based on the "Loss Free Resistor" concept is presented. This simple model correctly describes the basic power processing properties of the Active Power Factor Corrector, including input port resistor emulation, output port power some characteristics.teristics.

  • PDF