• 제목/요약/키워드: Power utility

검색결과 1,082건 처리시간 0.036초

An Efficient and High-gain Inverter Based on The 3S Inverter Employs Model Predictive Control for PV Applications

  • Abdel-Rahim, Omar;Funato, Hirohito;Junnosuke, Haruna
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권4호
    • /
    • pp.1484-1494
    • /
    • 2017
  • We present a two-stage inverter with high step-up conversion ratio engaging modified finite-set Model Predictive Control (MPC) for utility-integrated photovoltaic (PV) applications. The anticipated arrangement is fit for low power PV uses, the calculated efficiency at 150 W input power and 19 times boosting ratio was around 94%. The suggested high-gain dc-dc converter based on Cockcroft-Walton multiplier constitutes the first-stage of the offered structure, due to its high step-up ability. It can boost the input voltage up to 20 times. The 3S current-source inverter constitutes the second-stage. The 3S current-source inverter hires three semiconductor switches, in which one is functioning at high-frequency and the others are operating at fundamental-frequency. The high-switching pulses are varied in the procedure of unidirectional sine-wave to engender a current coordinated with the utility-voltage. The unidirectional current is shaped into alternating current by the synchronized push-pull configuration. The MPC process are intended to control the scheme and achieve the subsequent tasks, take out the Maximum Power (MP) from the PV, step-up the PV voltage, and introduces low current with low Total Harmonic Distortion (THD) and with unity power factor with the grid voltage.

계통연계 태양광발전시스템용 단상 인버터의 설계 및 제어 (Design and Control of the Single-phase Inverter for Utility Interactive Photovoltaic Generation System)

  • 황인호;성세진
    • 태양에너지
    • /
    • 제17권1호
    • /
    • pp.27-33
    • /
    • 1997
  • 최근 태양전지, 연료전지를 이용한 새로운 발전시스템이 개발중에 있다. 특히 소규모 분산형 계통연계 태양광발전시스템은 가까운 장래에 폭 넓게 보급될것으로 예상된다. 태양전지 어레이를 계통선과 결합하는데 사용되는 인버터는 전체 태양광발전시스템의 성능을 결정하는 중요한 요소이다. 본 논문에서는 고조파를 포함한 무효전력 보상능력을 갖는 단상 태양광 인버터 시스템의 설계 및 제어기법을 제시하였다. 제안된 인버터 시스템에 의해 정류기 부하에 의해 발생된 무효전력이 보상될 수 있음을 실험결과로 보여준다.

  • PDF

계통 연계형 태양광 발전 시스템의 실계통 적용을 위한 시뮬레이션 모델에 관한 연구 (A Study on the Simulation Model of PV Generation System for its Application to Real Power System)

  • 이계병;손광명;전인수
    • 조명전기설비학회논문지
    • /
    • 제22권6호
    • /
    • pp.70-78
    • /
    • 2008
  • 본 논문에서는 태양광 발전시스템을 전력회사의 실배전 계통에 적용하기 위한 시뮬레이션 모델링을 제시한다. 태양광 발전시스템이 실배전 계통에 미치는 영향을 해석하기 위하여, 태양광 발전시스템과 이를 실배전 계통에 적용한 시뮬레이션 모델을 PSCAD/EMTDC를 이용하여 모델링하였다. 태양광 발전 시스템의 적용 후 변전소로부터의 전력공급을 감소시킴으로써 부하 말단전압이 개선됨을 보였다. 또한 부하모선의 전압을 보상함으로써 부하 측의 전력품질이 개선됨을 보였다.

Resource allocation algorithm for space-based LEO satellite network based on satellite association

  • Baochao Liu;Lina Wang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제18권6호
    • /
    • pp.1638-1658
    • /
    • 2024
  • As a crucial development direction for the sixth generation of mobile communication networks (6G), Low Earth Orbit (LEO) satellite networks exhibit characteristics such as low latency, seamless coverage, and high bandwidth. However, the frequent changes in the topology of LEO satellite networks complicate communication between satellites, and satellite power resources are limited. To fully utilize resources on satellites, it is essential to determine the association between satellites before power allocation. To effectively address the satellite association problem in LEO satellite networks, this paper proposes a satellite association-based resource allocation algorithm. The algorithm comprehensively considers the throughput of the satellite network and the fairness associated with satellite correlation. It formulates an objective function with logarithmic utility by taking the logarithm and summing the satellite channel capacities. This aims to maximize the sum of logarithmic utility while promoting the selection of fewer associated satellites for forwarding satellites, thereby enhancing the fairness of satellite association. The problems of satellite association and power allocation are solved under constraints on resources and transmission rates, maximizing the logarithmic utility function. The paper employs an improved Kuhn-Munkres (KM) algorithm to solve the satellite association problem and determine the correlation between satellites. Based on the satellite association results, the paper uses the Lagrangian dual method to solve the power allocation problem. Simulation results demonstrate that the proposed algorithm enhances the fairness of satellite association, optimizes resource utilization, and effectively improves the throughput of LEO satellite networks.

디지털 PLL 제어의 특성 분석 (The Analysis of Characteristics for Digital PLL Control)

  • 김용균;최종우;김흥근
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.548-553
    • /
    • 2003
  • The frequency and phase angle of the utility voltage are important in many industrial systems. this paper present a detailed analysis of single-phase digital PLL control for utility connected systems. and its performance under utility conditions with noise is discussed. The experimental results demonstrate phase tracking capability in the single-phase grid-connected operation.

  • PDF

Utility Interactive Solar Power Conditioner with Zero Voltage Soft Switching High frequency Sinewave Modulated Inverter Link

  • Terai H.;Sumiyoshi S.;Kitaizumi T.;Omori H.;Ogura K.;Chandhaket S.;Nakaoka M.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.668-672
    • /
    • 2001
  • The utility interactive sinewave modulated inverter for the solar photovoltaic (PV) power conversion and conditioning with a new high frequency pulse modulated link is presented for domestic residential applications. As compared with the conventional full-bridge hard switching PWM inverter with a high frequency AC link, the simplest single-ended quasi-resonant soft switching sinewave modulated inverter with a duty cycle pulse control is implemented, resulting in size and weight reduction and low-cost. This paper presents a prototype circuit of the single-ended zero voltage soft switching sinewave inverter for solar power conditioner and its operating principle. In addition, this paper proposes a control system to deliver high quality output current. Major design of each component and the power loss analysis under actual power processing is also discussed from an experimental point of view. A newly developed interactive sinewave power processor which has $92.5\%$ efficiencty at 4kW output is demonstrated. It is designed 540mm-300mm-125mm in size, and 20kg in weight.

  • PDF

A Buck-Boost Type Charger with a Switched Capacitor Circuit

  • Wu, Jinn-Chang;Jou, Hurng-Liahng;Tsai, Jie-Hao
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.31-38
    • /
    • 2015
  • In this paper, a buck-boost type battery charger is developed for charging battery set with a lower voltage. This battery charger is configured by a rectifier circuit, an integrated boost/buck power converter and a switched capacitors circuit. A boost power converter and a buck power converter sharing a common power electronic switch are integrated to form the integrated boost/buck power converter. By controlling the common power electronic switch, the battery charger performs a hybrid constant-current/constant-voltage charging method and gets a high input power factor. Accordingly, both the power circuit and the control circuit of the developed battery charger are simplified. The switched capacitors circuit is applied to be the output of the boost converter and the input of the buck converter. The switched capacitors circuit can change its voltage according to the utility voltage so as to reduce the step-up voltage gain of the boost converter when the utility voltage is small. Hence, the power efficiency of a buck-boost type battery charger can be improved. Moreover, the step-down voltage gain of the buck power converter is reduced to increase the controllable range of the duty ratio for the common power electronic switch. A prototype is developed and tested to verify the performance of the proposed battery charger.

동특성해석을 위한 계통연계 풍력발전 시스템의 모델링 (Modeling of a Grid-Connected Wind Energy Conversion System for Dynamic Performance Analysis)

  • 추연식;노경수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1358-1360
    • /
    • 2002
  • This paper presents a modeling and simulation of a utility-connected wind energy conversion system with a link of a rectifier and an inverter. It discusses the maximum power control algorithm for the wind turbine and presents the relationship of wind turbine output, rotor speed, power coefficient, tip-speed ratio and wind speed when the wind turbine is operated under the maximum power control algorithm. The control objective is to extract maximum power from wind and transfer the power to the utility. This is achieved by controlling the pitch angle of the wind turbine blades. Pitch control method is mechanically complicated, but the control performance is better than that of the stall regulation method. The simulation results performed on MATLAB will show the variation of generator's rotor speed, pitch angle, and generator output.

  • PDF

제주행원 풍력발전단지의 전압품질 및 연계기준 적합성 분석 (Voltage quality and Network Interconnection Standard Suitability in Jeju-Hangwon Wind Power Generation Farm)

  • 김세호;김일환;허종철
    • 한국태양에너지학회 논문집
    • /
    • 제26권2호
    • /
    • pp.53-59
    • /
    • 2006
  • The number of wind generation installations are growing substantially in Jeju, Korea. Many of these installations are significant in size and directly connected to the distribution system. Utility grid interconnection standards for interconnecting non-utility distributed generation systems are essential to both power system company and generation company. These interconnection standards are important to utilities, customers, wind generation manufactures and nation. In this paper, it is investigated the voltage quality and the suitability of Jeju-Hangwon wind power generation farm by network interconnection technology standard.

배전계통 고조파 상시감시 시스템 구축 및 측정사례 (A case of the PQMS construction in the distribution power system)

  • 박용업;최선규;이병성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.418-419
    • /
    • 2011
  • Recently, the korea power quality standard has been established based on the IEC Std. By IEC Std., the power quality assessment point is measured in PCC. In this case, the utility has to construct PQM system in all customer PCC point and the PQ meter cost would be very high in order to acquire the suitable data. Accordingly the utilities could not apply to PQM system in the distribution power system by the cost and communication problem. In this paper, the proposed economical PQMS(Power quality monitoring system) of Utility.

  • PDF