• Title/Summary/Keyword: Power system operation

Search Result 5,497, Processing Time 0.03 seconds

Performance Analysis of Stepwise Parallel Processing for Cell Search in WCDMA over Rayleigh Fading Channels (레일리 페이딩 채널에서 WCDMA의 단계별 병렬 처리 셀 탐색의 성능 해석)

  • 송문규
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.2B
    • /
    • pp.125-136
    • /
    • 2002
  • It is very important to acquire the synchronization in a intercell asynchronous WCDMA system, and it is carried out through the three-step cell search process. The cell search can operate in a stepwise parallel manner, where each step works in pipelined operation, to reduce the cell search time. In case that the execution time is set to be the same in each step, excessive accumulations will be caused in both step 1 and step 3, because step 2 should take at least one frame for its processing. In general, the effect of post-detection integration becomes saturated as the number of the accumulations increases. Therefore, the stepwise parallel scheme does not give much enhancement. In this paper, the performance of the stepwise parallel processing for cell search in WCDMA system is analyzed over Rayleigh fading channels. Through the analysis, the effect of cell search parameters such as the number of accumulations in each step and the power ratio allocated among channels is investigated. In addition, the performance of the stepwise parallel cell search is improved by adjusting the execution time appropriately for each step and is compared with that of the conventional stepwise serial processing.

FPGA Modem Platform Design for eHSPA and Its Regularized Verification Methodology (eHSPA 규격을 만족하는 FPGA모뎀 플랫폼 설계 및 검증기법)

  • Kwon, Hyun-Il;Kim, Kyung-Ho;Lee, Chung-Yong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.2
    • /
    • pp.24-30
    • /
    • 2009
  • In this paper, the FPGA modem platform complying with 3GPP Release 7 eHSPA specifications and its regularized verification flow are proposed. The FFGA platform consists of modem board supporting physical layer requirements, MCU and DSP core embedded control board to drive the modem board, and peripheral boards for RF interfacing and various equipment interfaces. On the other hand, the proposed verification flow has been regularized into three categories according to the correlation degrees of hardware-software inter-operation, such as simple function test, scenario test call processing and system-level performance test. When it comes to real implementations, the emulation verification strategy for low power mobile SoC is also introduced.

ESTIMATION OF OFF-SITE DOSE AND RELEASE CONCENTRATION OF RADIOACTIVE LIQUID EFFLUENTS FROM RADWASTE TREATMENT SYSTEM IN KORI 3&4

  • Kim, H.S.;Son, J.K.;Kim, K.D.;Ha, J.H.;Song, M.J.
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.291-298
    • /
    • 2001
  • The designed release rate of liquid effluents from radwaste treatment system should be calculated and evaluated during normal operation, including anticipated operational occurrence and be assured that the release concentration and off-site dose at unrestricted area do not exceed the limits of regulation. The expected annual release rate and off-site dose for the currently operating nuclear power plants in Korea had been calculated and evaluated using PWR-GALE and LADTAP-II which was based on USNRC Regulatory Guide 1.109. Recently, the MOST Notice 2001-2 related to release concentration and off-site dose at unrestricted area was revised to reflect the concept of ICRP-60. It is necessary for KORI 3&4 to re-calculate the release concentration and off-site dose and to compare these results with the limits of regulation. As the results of assessment, we confirmed that the release concentrations were less than its limits of MOST Notice 2001-2 and the off-site dose at unrestricted area using K-DOSE60 was 3.61E-03 mSv/yr to the age of five for the effective dose, and 4.10E-2 mSv/yr to thyroid of the age of five for the organ equivalent dose. We also confirmed the off-site dose was within the limits of MOST Notice 2001-2. Therefore, the release concentration and off-site dose re-evaluated at unrestricted area in KORI 3&4 were well below the regulation limits of MOST Notice 2001-2.

  • PDF

Prediction of the Efficiency of Factors Affecting Pressure Drop in a Pulse Air Jet-type Bag Filter (충격기류식 여과집진장치에서 압력손실에 영향을 주는 인자의 효율예측)

  • Suh, Jeong-Min;Ryu, Jae-Yong;Lim, Woo-Taik;Jung, Moon-Sub;Park, Jeong-Ho;Shin, Choon-Hwan
    • Journal of Environmental Science International
    • /
    • v.19 no.4
    • /
    • pp.437-446
    • /
    • 2010
  • The pressure drop through pulse air jet-type bag filter is one of the most important factors on the operating cost of bagfilter houses. In this study, the pilot-scale pulse air jet-type bag filter with about 6 m2 filtration area was designed and tested for investigating the effects of the four operating conditions on the total pressure drop, using the coke dust collected from a steel mill factory. When the face velocity is higher than 2 m/min, it is not applicable to on-spot due to the increase of power expenses resulting from a high-pressure drop, and thus, 1.5 m/min is considered to be reasonable. The regression analysis results show that the degree of effects of independent parameters is a order of face velocity > concentration > time > pressure. The results of SPSS answer tree analysis also reveal that the operation time affects the pressure drop greatly in case of 1 m/min of face velocity, while the inlet concentration affects the pressure drop in case of face velocity more than 1.5 m/min.

Performance evaluation on Fault Current Controller System for the Applications of Smart Grid

  • Jang, Jae-Young;Lee, Woo-Seung;Lee, Ji-Ho;Hwang, Young-Jin;Jo, Hyun-Chul;Ahn, Min-Cheol;Hur, Kyeon;Ko, Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.2
    • /
    • pp.12-15
    • /
    • 2012
  • This paper presents simulation and small-scale experimental tests of a fault current controller. Smart fault controller as proposed and proven conceptually in our previous work is promising technology for the smart power grid where distributed and even stochastic generation sources are prevalent and grid operations are more dynamic. Existing protection schemes simply limiting the fault current to the pre-determined set values may not show best performance and even lead to coordination failures, potentially leading to catastrophic failure. Thus, this paper designs fault current controller with a full bridge thyristor rectifier, embedding a superconducting coil for which the controller is electrically invisible during normal operation because the loss due to the coil is near-zero. When a fault occurs and the resulting current through the superconducting coil exceeds a certain value set intelligently based on the current operating condition of the grid, the magnitude of the fault current is controlled to this desired value by adjusting the firing angles of thyristors such that the overall system integrity is successfully maintained. Detailed time-domain simulations are performed and lab-scale testing circuits are built to demonstrate the desired functionality and efficacy of the proposed fault current controller.

A Study on Estimation Method for Optimal Composition Rate of Hybrid ESS Using Lead-acid and Lithium-ion Batteries (연축전지와 리튬이온전지용 하이브리드 ESS의 최적구성방안에 관한 연구)

  • Park, Soo-Young;Ryu, Sang-Won;Park, Jae-Bum;Kim, Byung-Ki;Kim, Mi-Young;Rho, Dae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.6
    • /
    • pp.962-968
    • /
    • 2016
  • The large scaled lead-acid battery is widely used for efficient operation of the photovoltaic system in many islands. However, lithium-ion battery is now being introduced to mitigate the fluctuation of wind power and to replace lead-acid battery. Therefore, hybrid ESS(Energy Storage system) that combines lithium-ion battery with lead-acid battery is being required because lithium-ion battery is costly in present stage. Under this circumstance, this paper presents the optimal algorithm to create composition rate of hybrid ESS by considering fixed and variable costs in order to maximize advantage of each battery. With minimization of total cost including fixed and variable costs, the optimal composition rate can be calculated based on the various scenarios such as load variation, life cycle and cost trend. From simulation results, it is confirmed that the proposed algorithms are an effective tool to produce a optimal composition rate.

Prototype Development of 3-Phase 3.3kV/220V 6kVA Modular Semiconductor Transformer (3상 3.3kV/220V 6kVA 모듈형 반도체 변압기의 프로토타입 개발)

  • Kim, Jae-Hyuk;Kim, Do-Hyun;Lee, Byung-Kwon;Han, Byung-Moon;Lee, Jun-Young;Choi, Nam-Sup
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.12
    • /
    • pp.1678-1687
    • /
    • 2013
  • This paper describes a prototype of 3-phase 3.3kV/220V 6kVA modular semiconductor transformer developed in the lab for feasibility study. The developed prototype is composed of three single-phase units coupled in Y-connection. Each single-phase unit with a rating of 1.9kV/127V 2kVA consists of a high-voltage high-frequency resonant AC-DC converter, a low-voltage hybrid-switching DC-DC converter, and a low-voltage hybrid-switching DC-AC converter. Also each single-phase unit has two DSP controllers to control converter operation and to acquire monitoring data. Monitoring system was developed based on LabView by using CAN communication link between the DSP controller and PC. Through various experimental analyses it was verified that the prototype operates with proper performance under normal and sag condition. The system efficiency can be improved by adopting optimal design and replacing the IGBT switch with the SiC MOSFET switch. The developed prototype confirms a possibility to build a commercial high-voltage high-power semiconductor transformer by increasing the number of series-connected converter modules in high-voltage side and improving the performance of switching element.

A study on the greenhouse gas emission from ships with training ship HANBADA (실습선 한바다호를 이용한 선박부문 온실가스 배출량 산정에 관한 연구)

  • Lee, Sang Deuk;Koh, Dae Kwon;Jung, Suk Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.3
    • /
    • pp.240-245
    • /
    • 2014
  • As the seriousness of the global environment pollution is gaining our attention recently, researches on application of greenhouse gas emission of ship are being carried globally. However domestic study on greenhouse gas emission from ship was not carried out in various fields. In this study, quantitative data which was presented by greenhouse gas emission of training ship HANBADA and greenhouse gas emission was calculated by Tier 1 method based on total fuel consumption and amount of shore power. Actual voyage data for 1year in 2012 was used to analysis the greenhouse gas emission. This study showed how many weight of gases were exhausted per 1 gross tonnage and per 1trainee in the training ship. There is a need of further research to reduce pollutant and to respond to international environment regulation consistently.

Effect of $PC_6$ Moxibustion for Mental Stress on Short-term Analysis of Heart Rate Variability (내관(內關)($PC_6$) 애구(艾灸)가 정신적 스트레스를 가한 성인의 심박변이도에 미치는 영향)

  • Cho, Seong-Yeun;Jang, Jin-Young;Kim, So-Jung;Nam, Sang-Soo;Kim, Yong-Suk
    • Journal of Acupuncture Research
    • /
    • v.27 no.2
    • /
    • pp.51-58
    • /
    • 2010
  • Objectives : The purpose of this study was to assess the effect of $PC_6$ moxibustion treatment for reducing mental stress using power spectrum analysis of the heart rate variability(HRV). Methods : 20 healthy volunteers(simple rest group : 10, moxibustion treatment group : 10) participated in this study. After instrumentation and 5-minutes rest period, mental stress by operation was provided for 5-minutes. HRV was recorded before and after the mental stress. And then the simple rest group rested for 15-minutes. The moxibustion treatment group was treated by $PC_6$ moxibustion and rested for 15-minutes. And then HRV was recorded. Results : In simple rest group, LF norm and HF norm showed a significant change after mental stress. In moxibustion treatment group, LF, HF, LF norm, HF norm and LF/HF showed a significant change after mental stress. But there were no significant difference between two groups(p>0.05) except HF. In moxibustion treatment group, LF, LF norm, HF norm and LF/HF showed a significant change after moxibustion treatment. There were significant differences between two groups(p<0.05). Conclusions : The result suggests that $PC_6$ moxibustion treatment can regulate and prevent the alteration of autonomic nerve system by mental stress.

On-line Surface Defect Detection using Spatial Filtering Method (공간필터법을 이용한 온라인 표면결함 계측)

  • Moon, Serng-Bae;Jun, Seung-Hwan
    • Journal of Navigation and Port Research
    • /
    • v.28 no.1
    • /
    • pp.43-49
    • /
    • 2004
  • Defects inspection of commodities are very important with those design and manufacturing process and essential to strengthen the competitiveness of those. If on-line automatic defects detection is performed without damaging to products, the production cost shall be curtailed through the reducing man-power, economical management of Q.C(Quality Control). In this paper, it is suggested three spatial filtering methods which can extract the necessary information in case of defects being on the surface of object like iron plate. In addition, the dependence of filtering characteristics on parameters such as the pitch and width of slits is analyzed and the surface defect detection system is constructed. Several experiments were carried out for determining the adequate spatial filtering method through comparing and analyzing effects of parameters like defect's size and shape, intensity of light, noise of coherent source and slit number.