Harmonics Analysis and Modelling for Distribution System (배전 시스템의 고조파 분석 및 모델링에 관한 연구)

  • Sung Byung H;Wang Yong P;Chung Hyuong H;Park Hea C;Park In P
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.267-269
    • /
    • 2004
  • Recently, due to increasing the application of power electronic equipment, harmonics generated from the non-liner load are fairy produced. Harmonics can cause a distribution problems such as the overheating of distribution transformer, the breakdown of device and communication interference. Interest about power quality decline of distribution system is very increased. In this paper, we are measured the harmonic voltage and current of distribution system to analyze harmonic characteristics, and it is analyzed Total Harmonic Distortion(HTD). Also, we are modeled distribution system using PSCAD/EMTDC. And it is analyzed harmonic voltage and current in steady-state. The study result have been indicated the utility about harmonics analysis and modeling for distribution system.

  • PDF

Scott Transformer Modeling using Simulink on the AC Substation (Simulink를 이용한 교류 급전변전소의 스코트변압기 모델링)

  • Kim, Tae-Geun;Park, Young;Lee, Jong-Woo
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2317-2322
    • /
    • 2011
  • In three-phase power, when the power is supplied to the single phase load, there is the unbalance of load in the three-phase power. So the scott transformer is used in the power system to supply a single phase load in three-phase power without the unbalance of loads. Especially, the scott transformer is used in the AC substation of electric railroad. Two single phase transformers are combined by T-wiring in the scott transformer. So, two single phase voltage is provided by differing $90^{\circ}$ phase in three-phase power. The selection of related equipment and correction of protective relay are not easy from characteristic of the scott transformer when shunt and ground faults occur. In this paper, electric model of the scott transformer is suggested and the current of the scott transformer in shunt and ground faults is analyzed. Also, the scott transformer model is demonstrated by using Sinulink.

  • PDF

Model Updating of an Electric Cabinet using Shaking Table Test

  • Cui, Jintao;Cho, Sung-Gook;Kim, Doo-Kie;Koo, Ki-Young;Cho, Yang-Hee
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.59-62
    • /
    • 2008
  • This paper presents the procedure and the results of modal identification testing of a seismic monitoring system central processing unit cabinet for a nuclear power plant. This paper also provides a model updating for making effective analytical modeling of cabinet-type electrical equipment by comparing the test results with the analysis results. From the test results and their interpretation, modal properties (modal frequency, mode shape, and modal damping) of the specimen were satisfactorily identified. However, the analysis results may need to study further to find the effective and presentative model for the cabinet-type electrical equipment. This paper just presents the first stage of the research project "Development of dynamic behavior analysis technique of dynamic structure system" which is trying to build the lumped mass beam stick model even their results do not agree well with the test results.

  • PDF

LQ Control of Inverted Pendulum Using Hydraulic (유압을 이용한 도립진자의 LQ제어)

  • Jung, S.W.;Huh, J.Y.;Rhee, I.S.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.8 no.2
    • /
    • pp.1-7
    • /
    • 2011
  • An inverted pendulum mounted on a cart and actuated by a hydraulic servo cylinder was designed and built. Position information of the cart was acquired via a potentiometer and a angle of the pendulum was sensed by an incremental encoder. These were collected by a DAQ board and processed through the Real-Time Windows Target software(included in simulink). A simulink graphical program was implemented as a controller of the hydraulic system that governed the motion of the cart in order to maintain vertical balance of the inverted pendulum. The purpose of this study is to develop an electro-hydraulic inverted pendulum system for a modeling and controling the intrinsic unstable system. The simulation results were compared with the experimental and verified.

3D CAD Modeling of a Hydraulic Motor-Load System and Adaptive Control (유압모터-부하계의 3D CAD 모델링 및 적응제어)

  • Cho, S.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.8 no.2
    • /
    • pp.23-28
    • /
    • 2011
  • This paper investigates the motion control of a hydraulic motor-load system using the Simple Adaptive Control (SAC) method. The plant transfer function has been modelled mathematically. The open-loop responses have been obtained experimentally in order to identify the design parameters of transfer function. The hydraulic motor-load system has been modelled using the 3D CAD and imbedded in the hydraulic circuit simulation program to verify the overall performance. The experimental results confirm that the SAC method gives a good tracking performance compared to the PID control.

Modeling and PID Control of an Electro-Hydraulic Servo System (전기유압 서보시스템의 모델링과 PID 제어)

  • Lee, Se Jin;Kim, Cheol Jae;Kang, Yong Ju;Choi, Soon Woo;Huh, Jun Young
    • Journal of Drive and Control
    • /
    • v.16 no.4
    • /
    • pp.16-22
    • /
    • 2019
  • The electro-hydraulic training device (TP511) provided by Festo Didactic are widely used, but teaching materials do not include mathematical modeling. Thus, there is a limit for full-scale learning about the electro-hydraulic servo system by using this equipment. In this study, for the purpose of improving students' understanding of the classical control and modern control Festo's electro-hydraulic servo training device (TP511) was mathematically modeled and parameter values were calculated by examining the characteristics of each component. And P, PI, PD, and PID controllers highly used in the industrial field, were designed by using the root locus method to achieve the optimal gains and used for simulation and experiments using the Festo's electro-hydraulic servo training apparatus. The validity of the derived mathematical model and the calculated parameter values were verified through simulation and experiment. It was found that the p control can achieve the control target more effectively than the pid control for Festo's electro-hydraulic servo training system by using the root locus method.

Modeling of Bi-directional DC/DC Converter for Connecting DC Distribution System using EMTP (EMTP를 이용한 직류배전계통 연계용 양방향 DC/DC 컨버터 모델링)

  • Han, Joon;Kim, Doo-Ung;Oh, Yun-Sik;Gwon, Gi-Hyeon;Noh, Chul-Ho;Jung, Tack-Hyun;Kim, Chul-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.5
    • /
    • pp.615-621
    • /
    • 2014
  • With development of electrical power system, the DC distribution system has been considered as a promising technology to be used in the future smart distribution system. Among the various components comprising the DC distribution system, the bi-directional DC/DC converter is one of the most important equipment to interconnect between main power system and various renewable resources such as photovoltaic power generation, wind power generation, and electrical vehicles. In this paper, a bi-directional DC/DC converter based on three-phases interleaved method which is effective to reduce ripple of input current and output voltage is modeled using ElectroMagnetic Transient Program(EMTP), and the verification of modeled bi-directional DC/DC converter is conducted.

Assessment of Air Pollution and Estimation of Emission from Incheon International Airport by EDMS (EDMS를 이용한 인천국제공항의 대기오염 배출량 산정과 주변지역에 미치는 영향 평가)

  • Lee, Seong-Yong;Jang, Young-Kee
    • Journal of Environmental Impact Assessment
    • /
    • v.11 no.2
    • /
    • pp.67-77
    • /
    • 2002
  • Air traffic increased 12% annually in Korea since 1988 after the Olympics, this rate is two times than the rate of the world average. In order to accommodate fast growing aviation demand, Incheon International Airport is operated at Yongjong Island since March, 2001. The Incheon airport project will continue till 2020. After the final phase in 2020, Incheon International Airport will handle 100 million passengers, 530,000 flights and 7 million tons of cargo annually. In this study, air pollution from aircraft and other sources are calculated and assessed in Incheon International Airport area by EDMS(Emission and Dispersion Modeling System), which is a combined emission and dispersion model for airport. EDMS could also be considered power plant, incinerator and aircraft support equipment such as ground support equipment, aerospace ground equipment, auxiliary power units. And EDMS is recommended as preferred model for air quality assessment of the airport area by U.S. EP A. The result of this study shows that NOx emission from aircraft and support utility is estimated as 27,000 - 35,000 ton/yr and Namdong-Gu area in Incheon city is affected as 30-60 ppb by the NOx emission from these sources in 2020, the final phase of Incheon international airport construction.

Modeling and Controller Design of an Electro-Hydrostatic Actuator (정유압구동기(EHA)의 모델링과 제어기 설계)

  • Huh, J.Y.;Kim, H.H.;Lee, I.Y.
    • Journal of Drive and Control
    • /
    • v.12 no.2
    • /
    • pp.1-6
    • /
    • 2015
  • Recently, the Electro-Hydrostatic Actuator(EHA) has been developed as a result of research on energy saving. EHA is usually composed of a direct driven pump from an electric motor and is available to control cylinder displacement or velocity with high efficiency. In addition, it has the advantage of compactness, minimum leakage and availability of decentralized control. In this study, an EHA system was designed to decrease the path tracking error and manufactured for test. The linearization method provided in AMESim software was used to derive the model of EHA system. The derived model was applied to design the PI-D controller to effectively overcome the disturbance. The effectiveness of this controller was verified by further testing.