• 제목/요약/키워드: Power system equipment modeling

검색결과 109건 처리시간 0.028초

Development of Main Steam Line Break Mass and Energy Release Analysis with RETRAN-3D Code

  • Park, Young-Chan;Kim, Yoo
    • 에너지공학
    • /
    • 제12권2호
    • /
    • pp.93-100
    • /
    • 2003
  • An estimation methodology of the mass and energy (M/E) release due to the main steam line break (MSLB) has been developed with the RETRAN-3D code. In the case of equipment qualification (EQ), the over-estimated temperature would exceed the design limits of some cables or valves. In order to have a more flexible EQ profiles from the MSLB M/E release, the methodology with the best-estimated code was used. The major conditions affecting the MSLB M/E were found to be the initial SG level, heat transfer between primary and secondary sides, power level, operable protection system, main or auxiliary feedwater availability, and break conditions. The RETRAN-3D models were developed for the Kori unit 1 (KRN-1) which is typical two loop Westinghouse (WH) designed plant. Particularly, a detailed model of the steam generators was developed to estimate a more realistic two-phase heat transfer effect of the steam flow. After the modeling, the methodology has been developed through the sensitivity analyses. The M/E release data generated from the analyses have been used as the input to the inside containment pressure and temperature (P/T) analysis. According to the results at the point of view containment P/T, the Kori unit 1 can have more margin of 5∼15 ㎪ in pressure and 8∼15$^{\circ}C$ in temperature.

MCV용 IMV개발을 위한 기초설계 (Basic Design for Development of IMV for MCV)

  • 허준영;정규홍
    • 드라이브 ㆍ 컨트롤
    • /
    • 제15권3호
    • /
    • pp.49-56
    • /
    • 2018
  • Construction machinery is used to improve productivity in civil engineering work and construction work, and it is a lengthy operation, and consumes considerable fuel to cope with large loads. As a result, productivity and fuel consumption of the construction machine become the main deciding factors. In the hydraulic system of the excavator, the main control valve is the most critical position for control. The flow distribution for control performance is achieved by the metering orifice, that causes critical energy loss. To improve this, we propose a combination of a three port proportional pressure reducing valve and a poppet type flow control valve as an IMV to replace the existing spool type MCV. To validate the proposal, we analyze static characteristics by modeling mathematically, and analyze dynamic characteristics. Simulation using the AMESim software on the regeneration circuit of the boom cylinder up-down operation, verifies the energy-saving effect compared to the existing MCV when IMV is used.

직접제어 방식을 이용한 소형 지게차 변속감도 시뮬레이션에 관한 연구 (A Study on Simulation of Shift Sensitivity of Small Forklift Transmission using Direct Control Method)

  • 정영만;양순용
    • 드라이브 ㆍ 컨트롤
    • /
    • 제11권4호
    • /
    • pp.8-14
    • /
    • 2014
  • The transmission control method of a small forklift is classified into a pilot control method and a direct control method. In the pilot control method, the complex hydraulic circuit consists of many components, making the production process too costly and time consuming. The direct control method contains fewer components that can be configured to simple hydraulic circuits. As another advantage, the input profile easily changes the shift sensitivity of the transmission. Therefore, this research considers the characteristics of the direct control method in the development of hydraulic system design. This paper will present a simulation of the direct control transmission using AMESim. First, modeling of the direct control method is obtained and simulated with real parameters. The simulation results then are carried out and compared with the experimental results to verify and analyze the characteristics of the direct control method.

분자체를 이용한 LNG 액화 플랜트 탈수 공정의 효율성 향상에 관한 연구 (Study on the Improvement of Efficiency in Dehydration Process of LNG Liquefaction Plant Using Molecular Sieve)

  • 박종화;유돈상;조대명
    • 한국수소및신에너지학회논문집
    • /
    • 제35권1호
    • /
    • pp.105-113
    • /
    • 2024
  • The natural gas dehydration process plays a central role in liquefying LNG. This study proposes two natural gas dehydration process systems applicable to liquefied natural gas (LNG) liquefaction plants, and compares and analyzes energy optimization measures through simulation. The fuel gas from feed stream (FFF) case, which requires additional equipment for gas circulation, disadvantages are design capacity and increased energy. On the other hand, the end flash gas (EFG) case has advantages such as low initial investment costs and no need for compressors, but has downsides such as increased power energy and the use of gas with different components. According to the process simulation results, the required energy is 33.22 MW for the FFF case and 32.86 MW for the EFG case, confirming 1.1% energy savings per unit time in the EFG case. Therefore, in terms of design pressure, capacity, device configuration, and required energy, the EFG case is relatively advantageous. However, further research is needed on the impact of changes in the composition of regenerated gas on the liquefaction process and the fuel gas system.

진동시험을 이용한 원자력발전소 캐비닛 구조의 지진응답예측기법 (Seismic Response Prediction Method of Cabinet Structures in a Nuclear Power Plant Using Vibration Tests)

  • 구기영;취진타오;조성국;김두기
    • 한국지진공학회논문집
    • /
    • 제12권5호
    • /
    • pp.57-63
    • /
    • 2008
  • 본 연구는 원자력발전소에 설치되는 캐비닛형 전기기기의 동적 진동시험 자료를 이용하여 캐비닛의 지진응답을 예측할 수 있는 기법을 제안하였다. 제안된 기법은 1) 절점질량 이상화 모델에 기반한 등가 지진하중 산정, 2) 진동시험자료에 기반한 캐비닛 구조의 입출력 상태방정식 규명, 3) 산정된 등가지진하중과 규명된 입출력 상태방정식을 사용한 지진응답산정의 과정으로 구성된다. 제안된 기법은 유한요소기법(FEM) 모델 개선(Model Updating)에 기반한 지진응답예측기법에 비하여 모델링 오차가 개입 되지 않는 장점을 가진다. 캐비넷 구조를 이상화한 2차원 프레임 모델과 3차원 상세 모델에 대한 수치검증을 통하여 제안된 기법이 지진응답을 매우 정확하게 예측을 함을 관찰하였고, 측정 노이즈에 대해서도 강인함을 관찰하였다. 추후연구로 실험검증이 요구된다.

A Systems Engineering Approach to Predict the Success Window of FLEX Strategy under Extended SBO Using Artificial Intelligence

  • Alketbi, Salama Obaid;Diab, Aya
    • 시스템엔지니어링학술지
    • /
    • 제16권2호
    • /
    • pp.97-109
    • /
    • 2020
  • On March 11, 2011, an earthquake followed by a tsunami caused an extended station blackout (SBO) at the Fukushima Dai-ichi NPP Units. The accident was initiated by a total loss of both onsite and offsite electrical power resulting in the loss of the ultimate heat sink for several days, and a consequent core melt in some units where proper mitigation strategies could not be implemented in a timely fashion. To enhance the plant's coping capability, the Diverse and Flexible Strategies (FLEX) were proposed to append the Emergency Operation Procedures (EOPs) by relying on portable equipment as an additional line of defense. To assess the success window of FLEX strategies, all sources of uncertainties need to be considered, using a physics-based model or system code. This necessitates conducting a large number of simulations to reflect all potential variations in initial, boundary, and design conditions as well as thermophysical properties, empirical models, and scenario uncertainties. Alternatively, data-driven models may provide a fast tool to predict the success window of FLEX strategies given the underlying uncertainties. This paper explores the applicability of Artificial Intelligence (AI) to identify the success window of FLEX strategy for extended SBO. The developed model can be trained and validated using data produced by the lumped parameter thermal-hydraulic code, MARS-KS, as best estimate system code loosely coupled with Dakota for uncertainty quantification. A Systems Engineering (SE) approach is used to plan and manage the process of using AI to predict the success window of FLEX strategies under extended SBO conditions.

Conception and Modeling of a Novel Small Cubic Antenna Design for WSN

  • Gahgouh Salem;Ragad Hedi;Gharsallah Ali
    • International Journal of Computer Science & Network Security
    • /
    • 제24권2호
    • /
    • pp.53-58
    • /
    • 2024
  • This paper presents a novel miniaturized 3-D cubic antenna for use in wireless sensor network (WSN) application. The geometry of this antenna is designed as a cube including a meander dipole antenna. A truly omnidirectional pattern is produced by this antenna in both E-plane and H-plane, which allows for non-intermittent communication that is orientation independent. The operating frequency lies in the ISM band (centered in 2.45 GHz). The dimensions of this ultra-compact cubic antenna are 1.25*1.12*1cm3 which features a length dimension λ/11. The coefficient which presents the overall antenna structure is Ka=0.44. The cubic shape of the antenna is allowing for smart packaging, as sensor equipment may be easily integrated into the cube hallow interior. The major constraint of WSN is the energy consumption. The power consumption of radio communication unit is relatively high. So it is necessary to design an antenna which improves the energy efficiency. The parameters considered in this work are the resonant frequency, return loss, efficiency, bandwidth, radiation pattern, gain and the electromagnetic field of the proposed antenna. The specificity of this geometry is that its size is relatively small with an excellent gain and efficiency compared to previously structures (reported in the literature). All results of the simulations were performed by CST Microwave Studio simulation software and validated with HFSS. We used Advanced Design System (ADS) to validate the equivalent scheme of our conception. Input here the part of summary.

철골용 클램프 시공방향에 따른 변형 및 성능확인 (Steel Frame Clamp Deformation and Performance Check based on Clamping Orientation)

  • 모승언;임남기
    • 한국건축시공학회지
    • /
    • 제22권2호
    • /
    • pp.161-169
    • /
    • 2022
  • 정부[3]에서는 강관비계를 재래식 비계로 규정하고 일체형 작업발판인 시스템비계를 우선 설치하도록 제도화 하고 강관비계의 사용을 최대한 지양하고 있는 추세이다. 하지만 발전소, 플랜트 현장 등 장비의 진입이 안 되거나 본 구조물의 구조가 복잡한 곳, 그리고 지면에서 비계를 쌓아 올리지 못하는 곳에서는 강관비계를 설치하여 작업할 수 밖에 없다. 고소부위의 H-beam 구조물에 강관비계를 설치하여 작업자들이 안전하게 작업을 할 수 있도록 작업공간을 형성하기 위해서는 철골용 클램프의 성능은 매우 중요한 요소이다. 본 연구에서는 철골용 클램프의 설치 방향별 부재의 변형 및 인장하중에 대해 성능시험 및 구조해석 모델링을 통해 확인한 결과 설치 방향별 성능은 안전인증 기준인 인장하중 10,000N을 만족하는 것으로 확인 되었다. 다만 성능값은 만족하지만 부착부 누름 볼트의 변형발생이 확인되었고, 부착부 본체는 변형이 미미한 것으로 확인되었으므로 철골용 클램프는 하중이 전달되는 방향으로 설치하여 부착부 본체에 하중이 제대로 전달될 수 있도록 하는 것이 보다 안전한 방법이다.

지하공동구내 가연성케이블의 열화접촉으로 인한 화재위험성 예측평가 (Study on the Fire Risk Prediction Assessment due to Deterioration contact of combustible cables in Underground Common Utility Tunnels)

  • Ko, Jaesun
    • 한국재난정보학회 논문집
    • /
    • 제11권1호
    • /
    • pp.135-147
    • /
    • 2015
  • 최근 지하공동구(Underground Common Utility Tunnels)는 도시민이 일상생활을 영위하는데 필요한 전기, 통신, 상수도, 도시 가스, 하수도뿐만 아니라 냉난방시설, 진공 집진관, 정보처리케이블 등의 시설물을 2종 이상 공동으로 수용하기 위한 지하시설물로서 국가의 중추기능을 담당하는 시설이지만, 화재 사고시 신속한 대처가 힘들고 각종 케이블 연소시 발생하는 유독가스 및 연기에 의해 공동구 내에 진입하여 진압하기가 힘들다. 따라서 화재발생시 막대한 재산피해 및 통신두절 등 국가의 중추신경이 마비됨은 물론 시민불편사항을 초래하게 된다. 따라서 본 논문은 지금까지 발생 되어온 국내,외 공동구 화재사례에서 화재발생의 주요원인으로 전기공사로 인한 합선 및 가연성케이블에 의한 열화접촉으로 화재가 발생하는 것이 대다수를 차지하고 있음에 착안하여 실제 공동구 모형을 제작하고 화재를 재현함으로서 과학적으로 화재의 성상을 분석하는데 그 목적이 있다. 화재실험은 지하공동구 내에 정온식 감지선형 감지기(Line type fixed temperature detector), 방화문(Fire door), 연결살수설비(Connection deluge set), 및 환기설비를 설치하고, 송 배전케이블은 일정구간 내화(Fireproof)도료로 도장하며, 난방관은 내화 피복된 상태에서 실험하였다. 그 결과 Type II의 경우 최고온도가 $932^{\circ}C$로 측정되었고, 일정한 온도에서 정온식감지선형감지기가 화재위치를 정확하게 수신반에 표시되었다. 그리고 Type III의 경우인 송 배전케이블은 일정구간 내화도료로 도장한 것은 내화성능이 없는 것으로 나타났고, 내화피복(Fireproof covered)된 난방관은 약 30분 정도의 내화성능이 있는 것으로 나타났다. 또한 화재뮬레이션 결과는 실물화재시험시의 화재하중(Fire load)을 입력하여 실시한 결과로서 최고온도가 $943^{\circ}C$로 실물화재실험시의 $932^{\circ}C$와 거의 일치 하였다. 따라서 공동구 화재하중만으로 화재시뮬레이션을 실시하여 화재성상에 대한 예측이 가능한 것으로 판단되며 시뮬레이션으로 얻은 열방출률(Heat release rate), 연기층의 높이, 산소(O2), 일산화탄소(CO), 이산화탄소(CO2)의 농도 등의 결과 값들은 실제 화재실험시의 값으로 적용시킬 수 있는 것으로 판단된다. 향후 본 연구에서 구축한 국내 지하공동구 화재사고에 대한 실험자료 및 매년 지속적으로 화재사례들을 분석하여 축적하고 법 규정 및 관리 메뉴얼 등을 보완함으로써 국내 지하공동구 화재사고에 대한 보다 신뢰성 있는 정보를 제공해 줄 수 있을 것이며, 효과적이고 체계적으로 지하공동구의 신설 및 유지 관리 보수에 기여할 것으로 기대된다.