• 제목/요약/키워드: Power system dynamic performance

검색결과 792건 처리시간 0.034초

전력계통의 안정도 향상을 위한 적응 뉴로 퍼지 전, 보상기 설계 (Design of Adaptive Neurofuzzy-based Precompensator for enhancement of Power System Stability)

  • 정문규;정현화;정형환;이광우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.218-220
    • /
    • 2000
  • In this paper, the problem of the design of an intelligent type precompensator is discussed for the performance improvement of a power system stabilizer(PSS). An advantage of the scheme is that an existing PSS can be easily modified in our control structure simply by adding an adaptive neurofuzzy-based precompensator. The overall system has been tested on a simulation model in different operation conditions. Case studies show the proposed scheme can provide the good damping of the power system over the wide range of operating conditions and improve the dynamic performance of the system.

  • PDF

A Hybrid Static Compensator for Dynamic Reactive Power Compensation and Harmonic Suppression

  • Yang, Jia-qiang;Yang, Lei;Su, Zi-peng
    • Journal of Power Electronics
    • /
    • 제17권3호
    • /
    • pp.798-810
    • /
    • 2017
  • This paper presents a combined system of a small-capacity inverter and multigroup delta-connected thyristor switched capacitors (TSCs). The system is referred to as a hybrid static compensator (HSC) and has the functions of dynamic reactive power compensation and harmonic suppression. In the proposed topology, the load reactive power is mainly compensated by the TSCs. Meanwhile the inverter is meant to cooperate with TSCs to achieve continuous reactive power compensation, and to filter the harmonics generated by nonlinear loads and the TSCs. First, the structure and mathematical model of the HSC are discussed Then the control method of the HSC is presented. An improved reduced order generalized integrator (ROGI)-based selective current control method is adopted in the inverter to achieve high-performance reactive and harmonic current compensation. Meanwhile, a switch control strategy is proposed to implement precise and fast switching of the TSCs and to avoid changing the time delay needed by the conventional switch strategy. Experiments are implemented on a 20 KVA HSC prototype and the obtained results verify the validity of the proposed HSC system.

Reduced Switch Count Topology of Current Flow Control Apparatus for MTDC Grids

  • Diab, Hatem Yassin;Marei, Mostafa Ibrahim;Tennakoon, Sarath B.
    • Journal of Power Electronics
    • /
    • 제16권5호
    • /
    • pp.1743-1751
    • /
    • 2016
  • The increasing demand for high voltage DC grids resulting from the continuous installation of offshore wind farms in the North Sea has led to the concept of multi-terminal direct current (MTDC) grids, which face some challenges. Power (current) flow control is a challenge that must be addressed to realize a reliable operation of MTDC grids. This paper presents a reduced switch count topology of a current flow controller (CFC) for power flow and current limiting applications in MTDC grids. A simple control system based on hysteresis band current control is proposed for the CFC. The theory of operation and control of the CFC are demonstrated. The key features of the proposed controller, including cable current balancing, cable current limiting, and current nulling, are illustrated. An MTDC grid is simulated using MATLAB/SIMULINK software to evaluate the steady state and dynamic performance of the proposed CFC topology. Furthermore, a low power prototype is built for a CFC to experimentally validate its performance using rapid control prototyping. Simulation and experimental studies indicate the fast dynamic response and precise results of the proposed topology. Furthermore, the proposed controller offers a real solution for power flow challenges in MTDC grids.

Modeling of 18-Pulse STATCOM for Power System Applications

  • Singh, Bhim;Saha, R.
    • Journal of Power Electronics
    • /
    • 제7권2호
    • /
    • pp.146-158
    • /
    • 2007
  • A multi-pulse GTO based voltage source converter (VSC) topology together with a fundamental frequency switching mode of gate control is a mature technology being widely used in static synchronous compensators (STATCOMs). The present practice in utility/industry is to employ a high number of pulses in the STATCOM, preferably a 48-pulse along with matching components of magnetics for dynamic reactive power compensation, voltage regulation, etc. in electrical networks. With an increase in the pulse order, need of power electronic devices and inter-facing magnetic apparatus increases multi-fold to achieve a desired operating performance. In this paper, a competitive topology with a fewer number of devices and reduced magnetics is evolved to develop an 18-pulse, 2-level $\pm$ 100MVAR STATCOM in which a GTO-VSC device is operated at fundamental frequency switching gate control. The inter-facing magnetics topology is conceptualized in two stages and with this harmonics distortion in the network is minimized to permissible IEEE-519 standard limits. This compensator is modeled, designed and simulated by a SimPowerSystems tool box in MATLAB platform and is tested for voltage regulation and power factor correction in power systems. The operating characteristics corresponding to steady state and dynamic operating conditions show an acceptable performance.

회로 시뮬레이션을 위한 MOS 제어 다이리스터의 PSPICE 모델 (A Pspice Model of MOS-Controlled Thyrister for Circuit Simlulation)

  • 이영국;현동석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.382-384
    • /
    • 1995
  • The advancement of power semiconductor devices has given great attribution to the performance and reliability or power conversion systems. But contemporary power devices have room for improvement. So much interest and endeavor are being applied to develop an improved power devices. The MOS-Controlled Thyristor(MCT)is a recently developed power device which combines four layers thyristor structure and MOS-gate. Owing to advantages compared to other devices in many respects, the MCT attracts much notice recently. Nowadays, in designing and manufacturing power conversion systems, the importance of circuit simulation for reducing cost and time is incensed. And to excute the simulation that resemble the real system as much as possible, to develop a model of power device that provides properly static and dynamic characteristics is important. So, this paper presents a PSPICE model of the MCT considering dynamic characteristics.

  • PDF

Adaptive Online Voltage Scaling Scheme Based on the Nash Bargaining Solution

  • Kim, Sung-Wook
    • ETRI Journal
    • /
    • 제33권3호
    • /
    • pp.407-414
    • /
    • 2011
  • In an effort to reduce energy consumption, research into adaptive power management in real-time systems has become widespread. In this paper, a novel dynamic voltage scaling scheme is proposed for multiprocessor systems. Based on the concept of the Nash bargaining solution, a processor's clock speed and supply voltage are dynamically adjusted to satisfy these conflicting performance metrics. In addition, the proposed algorithm is implemented to react adaptively to the current system conditions by using an adaptive online approach. Simulation results clearly indicate that the superior performance of the proposed scheme can strike the appropriate performance balance between contradictory requirements.

Development of an Advanced Hybrid Energy Storage System for Hybrid Electric Vehicles

  • Lee, Baek-Haeng;Shin, Dong-Hyun;Song, Hyun-Sik;Heo, Hoon;Kim, Hee-Jun
    • Journal of Power Electronics
    • /
    • 제9권1호
    • /
    • pp.51-60
    • /
    • 2009
  • Hybrid Electric Vehicles (HEVs) utilize electric power as well as a mechanical engine for propulsion; therefore the performance of HEV s can be directly influenced by the characteristics of the Energy Storage System (ESS). The ESS for HEVs generally requires high power performance, long cycle life and reliability, as well as cost effectiveness. So the Hybrid Energy Storage System (HESS), which combines different kinds of storage devices, has been considered to fulfill both performance and cost requirements. To improve operating efficiency, cycle life, and cold cranking of the HESS, an advanced dynamic control regime with which pertinent storage devices in the HESS can be selectively operated based on their status was presented. Verification tests were performed to confirm the degree of improvement in energy efficiency. In this paper, an advanced HESS with improved an Battery Management System (BMS), which has optimal switching control function based on the estimated State of Charge (SOC), has been developed and verified.

고분자전해질 연료전지(PEMFC)와 PEMFC/SCB의 동적 Matlab/Simulink 모델링 및 독립운전특성에 관한 연구 (A Study on the Comparison of the Stand-alone operation Characteristics and Matlab/Simulink Dynamic Model of PEMFC and PEMFC/SCB)

  • 홍원표;조재훈
    • 조명전기설비학회논문지
    • /
    • 제25권2호
    • /
    • pp.53-60
    • /
    • 2011
  • The available power generated from the FC power plant may not be sufficient to meet sustained load demand, peak demand or transient events. An supercapacitor bank(SCB) can supply a large burst of power, but it cannot store a significant amount of energy. The combined use of FC and SCB has the potential for the better energy efficiency, reducing the cost of FC technology and improved dynamic response. In this paper, A single PEMFC and PEMFC operated in parallel with a SC bank are presented, A new dynamic model of PEMFC system, the converter and controller has been developed for stand-alone applications. The simulation results are presented using Matlab/Simulink, and SimPowerSystems environments. It is confirmed that the results show a good performance and stable DC-link voltage for proposed dynamic and mathematical models developed for the combined FC/SCB.

부하 대응 제어방식을 적용한 축열식 히트펌프시스템의 성능 해석 (A Performance Analysis on a Heat pump with Thermal Storage Adopting Load Response Control Method)

  • 김동준;강병하;장영수
    • 설비공학논문집
    • /
    • 제30권3호
    • /
    • pp.130-142
    • /
    • 2018
  • We use heat pumps with thermal storage system to reduce peak usage of electric power during winters and summers. A heat pump stores thermal energy in a thermal storage tank during the night, to meet load requirements during the day. This system stabilizes the supply and demand of electric power; moreover by utilizing the inexpensive midnight electric power, thus making it cost effective. In this study, we propose a system wherein the thermal storage tank and heat pump are modeled using the TRNSYS, whereas the control simulations are performed by (i) conventional control methods (i.e., thermal storage priority method and heat pump priority method); (ii) region control method, which operates at the optimal part load ratio of the heat pump; (iii) load response control method, which minimizes operating cost responding to load; and (iv) dynamic programming method, which runs the system by following the minimum cost path. We observed that the electricity cost using the region control method, load response control approach, and dynamic programing method was lower compared to using conventional control techniques. According to the annual simulation results, the electricity cost utilizing the load response control method is 43% and 4.4% lower than those obtained by the conventional techniques. We can note that the result related to the power cost was similar to that obtained by the dynamic programming method based on the load prediction. We can, therefore, conclude that the load response control method turned out to be more advantageous when compared to the conventional techniques regarding power consumption and electricity costs.

A Catenary System Analysis for Studying the Dynamic Characteristics of a High Speed Rail Pantograph

  • Han, Chang-Soo;Park, Tong-Jin;Kim, Byung-Jin;Wang, Young-Yong
    • Journal of Mechanical Science and Technology
    • /
    • 제16권4호
    • /
    • pp.436-447
    • /
    • 2002
  • In this study, the dynamic response of a catenary system that supplies electrical power to high-speed trains is investigated. One of the important problems which is accompanied by increasing the speed of a high-speed rail, is the performance of stable current collection. Another problem which has been encountered, is maintaining continuous contact force between the catenary and the pantograph without loss of panhead. The dynamic analyses of the catenary based on the Finite Element Method (FEM) are performed to develop a pantograph suitable for high speed operation. The static deflection of the catenary, the stiffness variation in contact lines, the dynamic response of the catenary undergoing the force of a constantly moving load and the contact force were calculated. It was confirmed that a catenary model is necessary to study the dynamic characteristics of the pantograph system.