• 제목/요약/키워드: Power system control

검색결과 10,113건 처리시간 0.033초

전력계통(電力系統) 낙뢰감지(落雷感知) 및 진로예측(進路豫測) SYSTEM (Lightning Position and Tracking System for Power System Operation)

  • 홍사우;김영한;김재영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 A
    • /
    • pp.70-73
    • /
    • 1992
  • With regard to the supply of electric power in better quality, the problem of lightning is becoming more and more important in the operation of an electric power system. In this article a description is given of the new lightning position and tracking system which will be installed in KEPCO. The system is based on the principle of time-of-arrival (TOA) rather than the conventional direction-finding (DF) method.

  • PDF

Simulation for Pitch Angle Control Strategies of a Grid-Connected Wind Turbine System on MATLAB/Simulink

  • 노경수;최준호
    • 조명전기설비학회논문지
    • /
    • 제21권1호
    • /
    • pp.91-97
    • /
    • 2007
  • This paper presents a pitch angle controller of a grid-connected wind turbine system for extracting maximum power from wind and implements a modeling and simulation of the wind turbine system on MATLAB/Simulink. It discusses the maximum power control algorithm for the wind turbine and presents, in a graphical form, the relationship of wind turbine output, rotor speed, and power coefficient with wind speed when the wind turbine is operated under the maximum power control algorithm. The objective of pitch angle control is to extract maximum power from wind and is achieved by regulating the blade pitch angle during above-rated wind speeds in order to bypass excessive energy in the wind. Case studies demonstrate that the pitch angle control is carried out to achieve maximum power extraction during above-rated wind speeds and effectiveness of the proposed controller would be satisfactory.

안테나 배열을 이용한 CDMA 셀룰라 시스템에서 불완전 전력제어가 역방향 채널 용량에 미치는 효과 (The effect of imperfect power control on the capacity of reverse channel in cellular CDMA system with antenna arrays)

  • 김씨알;오성근
    • 한국통신학회논문지
    • /
    • 제21권2호
    • /
    • pp.471-482
    • /
    • 1996
  • In this paper, we analyze the effect of imperfect power control on the capacity of the reverse channel in CDMA cellular system with antenna arrays in the base station. For imperfect power control, we assume that the received power at the base station from the users within each cell has log-normal distribution, and we also consider the effect of imperfect power control of co-channel interferences which arise from both its own cell and outer cells. From the result of numerical analysis, we show that the degree of power control gives a great influence on the capacity of CDMA celluar system with antenna arrays, and also that antenna arrays at the base station can improve greatly the system capacity even when the power control is imperfect.

  • PDF

On Power System Frequency Control in Emergency Conditions

  • Bevrani, H.;Ledwich, G.;Ford, J. J.;Dong, Z.Y.
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권4호
    • /
    • pp.499-508
    • /
    • 2008
  • Frequency regulation in off-normal conditions has been an important problem in electric power system design/operation and is becoming much more significant today due to the increasing size, changing structure and complexity of interconnected power systems. Increasing economic pressures for power system efficiency and reliability have led to a requirement for maintaining power system frequency closer to nominal value. This paper presents a decentralized frequency control framework using a modified low-order frequency response model containing a proportional-integral(PI) controller. The proposed framework is suitable for near-normal and emergency operating conditions. An $H_{\infty}$ control technique is applied to achieve optimal PI parameters, and an analytic approach is used to analyse the system frequency response for wide area operating conditions. Time-domain simulations with a multi-area power system example show that the simulated results agree with those predicted analytically.

발전소 제어시스템 기본 스테이션 기능 검증 (Functional Test of A Station of Control System for Power Plant)

  • 변승현;박두용;임익헌
    • 전자공학회논문지SC
    • /
    • 제48권4호
    • /
    • pp.25-32
    • /
    • 2011
  • 국내 전력의 수요증가로 인해 전력산업에서 신경망 역할을 하는 I&C(Instrumentation & Control)의 중요성이 날로 증가하고 있으며, 외국 선진 제작사의 기술 보호로 제어 시스템의 국산화가 요구되고 있는 상황이다. 이러한 상황에서 500MW급 초임계압 표준 석탄화력 발전소에의 실증 적용을 목표로 국산 통합 감시 제어시스템 개발 연구가 진행되고 있다. 개발하는 통합 감시 제어시스템은 발전설비의 중요성으로 인해 개발과정이나 개발 후 발전 설비에 적용되기 전에 시스템의 기능 및 신뢰성 등의 검증이 요구되고 있다. 또한 전력수요의 증가로 인해 제어시스템 설치 및 시운전 기간의 충분한 확보가 어려운 시점에서, 향후 실증 적용시 시행착오를 줄이기 위해 제어 시스템의 검증은 필수적이다. 본 논문에서는 개발한 제어 시스템의 기본 스테이션에 대해 기능 검증한 사례를 소개한다.

최적 변조제어기를 이용한 전력시스템의 부하주파수 제어에 관한 연구 (A Study on the Load Frequency Control of Power System Using an Optimal Modulation Controller)

  • 정형환;허동렬;정문규;주석민;이준탁
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제26권3호
    • /
    • pp.299-306
    • /
    • 2002
  • The load frequency control(LFC) of power system is one of important subjects in view of system operation and control. That is, even though the rapid load disturbances are applied to the given power system, the stable and reliable power should be supplied to the users, converging unconditionally and rapidly the frequency deviations and the tie-line power flow ones of each area into allowable boundary limits. Nonetheless of such needs, if the internal parameter perturbation and the sudden load variation are given, the unstable phenomena of power systems can be often brought out because of the large frequency deviation and the unsuppressible power line one. So, an optimal modulation controller for UC of multi-area power system is designed by a recursive algorithm that determines the state weighting matrix Q of a linear quadratic performance criterion. The optimal modulation controller is based on optimal control and can obtain the exact dynamic response of the UC of multi-area power system in the time domain. The performances of the resultant optimal modulation control, that is, the steady-state deviations of frequency and tie-line power flow and the related dynamics, were investigated and analyzed in detail by being applied to the UC of multi-area power system in the perturbations of predetermined internal parameters. Through the simulation results tried variously in this paper for disturbance of stepwise load changes, the superiorities of the proposed optimal modulation controller in robustness and stability were proved.

스마트 홈에서 Zigbee 기반의 대기전력 제어 연구 (A Study of Standby Power Control Based on Zigbee in Smart Home)

  • 이성준;김도현
    • 한국멀티미디어학회논문지
    • /
    • 제17권7호
    • /
    • pp.879-885
    • /
    • 2014
  • This paper designs and implements the 2 plug type standby power control outlet based on IEEE 802.15.4 using Zigbee and IPv6 network in order to reduce the standby power to the user. The standby power control system is consisted of direct power and standby power plug. Also this system can communicate bidirectionally in wireless because built-in wireless communication modules. One gateway is linked with many standby power control outlet in wireless. Each standby power control outlet executes the operation needed in power control independently. Also each standby power control outlet has its own power can be detected in real time independently of the power can be controlled.

화력발전소용 digital back-up control system 적용에 관한 연구 (Application of digital back-up control system to fossile power plant)

  • 허성광;박익수;배병환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1988년도 한국자동제어학술회의논문집(국내학술편); 한국전력공사연수원, 서울; 21-22 Oct. 1988
    • /
    • pp.462-465
    • /
    • 1988
  • In this paper, it is described that digital back-up control system is developed and applied to the thermal power boiler control system which consists of many kinds of analog electronic cards. Also, by the installation of this system in ulsan power pllant, it was proven to have excellent capabilities of fault detection and digital back-up control.

  • PDF

퍼지로직을 이용한 이중여자 유도기의 역률제어 (Power Factor Control of a Doubly Fed Induction Machine using Fuzzy Logic)

  • 김재홍;김일환
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.268-271
    • /
    • 2001
  • This paper describes the power factor control of doubly fed induction machine using fuzzy logic algorithm in wind power generation system. Under fuzzy logic control, which enables superior dynamic performance, the power factor is independently controllable by decoupled d, q rotor experimental results are presented.

  • PDF

Ancillary Service Requirement Assessment Indices for the Load Frequency Control in a Restructured Power System with Redox Flow Batteries

  • Chandrasekar, K.;Paramasivam, B.;Chidambaram, I.A.
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권6호
    • /
    • pp.1535-1547
    • /
    • 2016
  • This paper proposes various design procedures for computing Power System Ancillary Service Requirement Assessment Indices (PSASRAI) for a Two-Area Thermal Reheat Interconnected Power System (TATRIPS) in a restructured environment. In an interconnected power system, a sudden load perturbation in any area causes the deviation of frequencies of all the areas and also in the tie-line powers. This has to be corrected to ensure the generation and distribution of electric power companies to ensure good quality. A simple Proportional and Integral (PI) controllers have wide usages in controlling the Load Frequency Control (LFC) problems. So the design of the PI controller gains for the restructured power system are obtained using Bacterial Foraging Optimization (BFO) algorithm. From the simulation results, the PSASRAI are calculated based on the settling time and peak over shoot concept of control input deviations of each area for different possible transactions. These Indices are useful for system operator to prepare the power system restoration plans. Moreover, the LFC loop coordinated with Redox Flow Batteries (RFB) has greatly improved the dynamic response and it reduces the control input requirements and to ensure improved PSASRAI, thereby improving the system reliability.