• Title/Summary/Keyword: Power series method

Search Result 843, Processing Time 0.043 seconds

A study on the Transformer Capability Containing Hormonic Load Currents (고조파를 포함하는 부하용 변압기 용량 산정에 관한 연구)

  • Kim, Kyung-Chul;Park, Sang-Young;Lee, Il-Moo;Lee, Joo-Hong;Jin, Seong-Eun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.5
    • /
    • pp.23-29
    • /
    • 2005
  • The increasing use of nonlinear loads has resulted in an increase in the harmonic content of the load current for power transformers. Transformers subject to harmonic currents have higher losses and need to be derated. This paper presents a simple method for determining the capability of transformers to supply harmonic load currents and shows that the application of capacitor banks with a series connected reactor and harmonic filters will greatly increase the capability of transformers.. The EDSA program was used as a simulation tool for the case study.

Design and Feedback Performance Analysis of the Inverter-side LC Filters Used in the DVR System (DVR시스템에 사용되는 인버터부의 LC필터 설계와 피드백 성능분석)

  • Park, Jong-Chan;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.2
    • /
    • pp.79-84
    • /
    • 2015
  • Voltage sags are considered the dominant disturbances affecting power quality. Dynamic voltage restorers(DVRs) are mainly used to protect sensitive loads from the electrical network voltage disturbances such as sags or swells and could be used to reduce harmonic distortion of ac voltages. The typical DVR topology essentially contains a PWM inverter with LC Filter, an injection transformer connected between the ac voltage line and the sensitive load, and a DC energy storage device. For injecting series voltage, the PWM inverter is used and the passive filter consist of inductor(L) and capacitor(C) for harmonics elimination of the inverter. However there are voltage pulsation responses by the characteristic of the LC passive filter that eliminate the harmonics of the PWM output waveform of the inverter. Therefore, this paper presented design and feedback performance of LC filter used in the DVRs. The voltage control by LC filter should be connected in the line side since this feedback method allows a relatively faster dynamic response, enabling the elimination of voltage notches or spikes in the beginning and in the end of sags and strong load voltage THD reduction. Illustrative examples are also included.

Analysis of the Electromagnetic Scattering by Conducting Strip Gratings with 2 Dielectric Layers (접지평면위에 2개의 유전체층을 가지는 도체띠 격자구조에서의 전자파산란 해석)

  • 김용연;방성일
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.4 no.1
    • /
    • pp.102-109
    • /
    • 1999
  • In this paper, Electromagnetic scattering problem by a perfectly conducting strip grating with 2 dielectric layer on a grounded plane by incidence of a electric wave is analyzed by applying the PMM (Point Matching Method) known as a simple procedure. The scattered electromagnetic fields are expanded in a series of Floquet mode functions. The boundary conditions are applied to obtain the unknown field coefficients and the conducting boundary condition is used for the relationship between the tangential electric field and the electric current density on the strip When the incident angle is normal incidence the minimum value of the geometrically normalized reflected power according as relative permittivity is increased it should be noted that the value of the strip width gets moved toward high value. Them most energy by a normal incident wave is scattered in direction of the other angles except normal incident angle.

  • PDF

An Experimental Study on Static Characteristics of Servo Valves using Transmission Line Pressures (배관 압력을 이용한 서보밸브 정적 특성에 관한 실험적 연구)

  • Kim, Sung Dong;Joo, Byeol Jin;Yun, So Nam
    • Journal of Drive and Control
    • /
    • v.13 no.2
    • /
    • pp.42-50
    • /
    • 2016
  • The conventional technique to measure the hysteresis and the null of servo valves is defined in ISO 10770-1 and based on load flow signal of the servo valve. A new technique based on the transmission line pressures is suggested in this study. The new measuring method was verified through a series of experiments. No hysteresis was observed between the spool displacement and the transmission line pressures, load pressure or each chamber pressure. Some hysteresis was observed between valve input and pressures, which was found to be the same as those of load flow and spool displacement for the valve input. By using the chamber pressures, the hysteresis and the null are easier to measure than the load pressure or differential pressure between those two chamber pressures because the chamber pressures showed sharp edges.

An Investigation of the Catalytic Effect with $Nd_{1-x}Sr_{x}CoO_{3}$ Perovskite in a Sealed-off $CO_2$ Laser

  • Oh Heui-Suk;Kim Sung-Ho;Cho Ung-In
    • Bulletin of the Korean Chemical Society
    • /
    • v.13 no.6
    • /
    • pp.593-595
    • /
    • 1992
  • To improve the lifetime and output power in a sealed-off $CO_2$ laser, a series of Nd$_{1-x}$Sr$_x$CoO$_3$(x = 0.0, 0.25, 0.40, 0.50, 0.60, 0.75) perovskite-type compounds has been synthesized and used for a cathode material. Using a typical method samples were sintered at 1150$^{\circ}$C and their structures were determined as a cubic form by means of XRD analysis. The degrees of $CO_2$ dissociation were measured by PAS (photoacoustic spectroscopy) with the lapse of time. In the case of $Nd_{0.4}$Sr$_{0.6}$$CoO_3$, which showed the highest catalytic cathode effect, only 7% of the initial $CO_2$ concentration were dissociated at 30 torr of gas mixture and 5 mA of discharge current. The more the gas pressure decreased and the discharge current increased, the more the degree of dissociation occurred. The ability of catalytic cathode to regenerate CO$_2$ in the laser cavity lies in order for x, 0.60 > 0.50 > 0.40 > 0.75 > 0.25 ${\gg}$ 0.0. Except for the case of x = 0.0 the amounts of $CO_2$ dissociation were found to be within 7-15% of the initial $CO_2$ concentration.

Self-Supported NiSe/Ni Foam: An Efficient 3D Electrode for High-Performance Supercapacitors

  • Zhang, Jingtong;Zhao, Fuzhen;Du, Kun;Zhou, Yan
    • Nano
    • /
    • v.13 no.11
    • /
    • pp.1850136.1-1850136.12
    • /
    • 2018
  • Three-dimensional (3D) mixed phases NiSe nanoparticles growing on the nickel foam were synthesized via a simple one-step hydrothermal method. A series of experiments were carried out to control the morphology by adjusting the amount of selenium in the synthetic reaction. Meanwhile, the as-prepared novel column-acicular structure NiSe exist three advantages including ideal electrical conductivity, high specific capacity and high cycling stability. It delivered a high capacitance of $10.8F\;cm^{-2}$ at a current density- of $5mA\;cm^{-2}$. An electrochemical capacitor device operating at 1.6 V was then constructed using NiSe/NF and activated carbon (AC) as positive and negative electrodes. Moreover, the device showed high energy density of $31W\;h\;kg^{-1}$ at a power density of $0.81kW\;kg^{-1}$, as well as good cycling stability (77% retention after 1500 cycles).

Frequency Spectrum Analysis of Corona Discharge Source Measured by Ultrasound Detector (초음파 감지기로 측정한 코로나 방전 소스의 주파수 스펙트럼 분석)

  • Cho, Hyun-Seob
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.1
    • /
    • pp.78-82
    • /
    • 2019
  • This paper addressed the spectrum of ultrasonic waves produced by arc and/or coronal discharge inside the switchboard. Portable ultrasound sensors are useful for detecting discharge phenomena, such as coronal means in electrical systems. However, a typical handheld ultrasound detector has a disadvantage of determining the type of problem by listening to the sound characteristics and predicting the results, as a result of the determination of whether a discharge is present. Therefore, a new method of analysis is required to distinguish ultrasonic characteristics. In this paper, we published an ultrasound analysis case study to visualize the sound of ultrasonic waves measured with ultrasonic sensors. From the results of the experiment, it was possible to detect coronal discharge and serial arc discharge without interference by the ultrasonic detection system.

Thermal Instability of Fluid in a Slot between Two Vertical Permeable Walls (두개의 수직 다공성 벽면을 가진 좁은 간격에서의 유체의 열적 불안정성)

  • Sohn, Dong-Yun;Yoo, Jung-Yul;Lee, Taik-Sik
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.13 no.4
    • /
    • pp.215-222
    • /
    • 1984
  • An analytical study on the thermal instability of fluid in a vertical solt between two permeable walls has been carried out using fast converging power series solution method. For given values of prandtl number Pr and permeability paramter ${\sigma}$, the critical Grashof number $Gr_c$ and the critical wave number ac are found as eigenvalues of the problem formulated by the stability equations and the appropriate boundary conditions which are derived on the basis of linear stability theory. In the case of ${\sigma}\;>\;10^4$, the results approach those of solid boundary case, but in the case of ${\sigma}\;<\;10^3$, the decrease of $Gr_c$ and $a_c$become more prominent. In other words, the permeable walls cause the flow to be more unstable than the solid walls. This is considered to be due to the slip of the fluid on the wail, which decrease the friction force.

  • PDF

IIoTBC: A Lightweight Block Cipher for Industrial IoT Security

  • Juanli, Kuang;Ying, Guo;Lang, Li
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.17 no.1
    • /
    • pp.97-119
    • /
    • 2023
  • The number of industrial Internet of Things (IoT) users is increasing rapidly. Lightweight block ciphers have started to be used to protect the privacy of users. Hardware-oriented security design should fully consider the use of fewer hardware devices when the function is fully realized. Thus, this paper designs a lightweight block cipher IIoTBC for industrial IoT security. IIoTBC system structure is variable and flexibly adapts to nodes with different security requirements. This paper proposes a 4×4 S-box that achieves a good balance between area overhead and cryptographic properties. In addition, this paper proposes a preprocessing method for 4×4 S-box logic gate expressions, which makes it easier to obtain better area, running time, and power data in ASIC implementation. Applying it to 14 classic lightweight block cipher S-boxes, the results show that is feasible. A series of performance tests and security evaluations were performed on the IIoTBC. As shown by experiments and data comparisons, IIoTBC is compact and secure in industrial IoT sensor nodes. Finally, IIoTBC has been implemented on a temperature state acquisition platform to simulate encrypted transmission of temperature in an industrial environment.

A Study on TE Scattering by a Conductive Strip Grating between Grounded Double Dielectric Layer (접지된 2중 유전체층 사이의 완전도체띠 격자구조에 의한 TE 산란에 관한 연구)

  • Yoon, Uei-Joong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.4
    • /
    • pp.153-158
    • /
    • 2016
  • In this paper, TE(transverse electric) scattering problems by a conductive strip grating between grounded double dielectric layer are analyzed by applying the PMM(point matching method) known as a numerical method of electromagnetic fileld. The boundary conditions are applied to obtain the unknown field coefficients, the scattered electromagnetic fields are expanded in a series of Floquet mode functions, and the conductive boundary condition is applied to analysis of the conductive strip. The numerical results for normalized reflected power are analyzed by according as the width and spacing of conductive strip, the relative permittivity and thickness of the double dielectric layers, and incident angles. The most normalized reflected powers of the sharp variations in minimum values are scattered in direction of the other angles except incident angle. The numerical results for the presented structure of this paper having a grounded double dielectric layer are shown in good agreement compared to those of the existing papers.