• Title/Summary/Keyword: Power series method

Search Result 843, Processing Time 0.034 seconds

Generation of Time Series Data from Octave Bandwidth SPL of Acoustic Loading Using Interpolation Method (보간법을 이용한 옥타브 밴드폭 음향 하중 SPL의 시계열 데이터 생성)

  • Go, Eun-Su;Kim, In-Gul;Jeon, Minhyeok;Cho, Hyun-Jun;Park, Jae-Sang;Kim, Min-Sung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.1-11
    • /
    • 2021
  • Thermal protection system structures such as double-panel structures are used on the skin of the fuselage and wings to prevent the transfer of high heat into the interior of an high supersonic/hypersonic aircraft. The thin-walled double-panel skin can be exposed to acoustic loads by high power engine noise and jet flow noise, which can cause sonic fatigue damage. In order to predict the fatigue life of the skin, the octave bandwidth SPL should be calculated as narrow bandwidth PSD or acoustic load history using interpolation method. In this paper, a method of converting the octave bandwidth SPL acoustic load into a narrow bandwidth PSD and reconstructed acoustic load history was investigated. The octave bandwidth SPL was converted to the narrow bandwidth PSD using various interpolation methods such as flat, log and linear scale, and the probabilistic characteristics and fatigue damage results were compared. It was found that average error of fatigue damage index by the log scale interpolation method was relatively small among three methods.

Design of acoustic meta-material silencer based on coiled up space (지그재그 구조 메타물질을 이용한 음향 소음기 설계)

  • Shim, Ki-Hwoon;Jang, Jun-Young;Kwon, Ho-Jin;Song, Kyungjun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.1
    • /
    • pp.31-37
    • /
    • 2021
  • In this paper, we design an acoustic meta-material silencer that operates at low frequency to reduce noise in duct. A high refractive index meta-material silencer is demonstrated with a combination of zigzag structured thin waveguide and helmholtz resonator, which reduces the speed of sound. Finite Element Method (FEM) analysis via thermo-viscous acoustic mesh is performed in order to calculate thermo-viscous dissipation in sub-wavelength waveguide. Sound power reflection, transmission and absorption coefficients are obtained utilizing 4-Microphone Method. The results show that cut-off frequency and transmission loss can be controlled through adjusting intervals of the zigzag structures. A wide-band acoustic silencer is also suggested by connecting meta-materials in series or parallel.

A Study on Optimization of Propulsion Systems for Series Hybrid Electric Vehicles Considering Mission Equipments (임무장비를 고려한 직렬형 하이브리드 차량의 추진시스템 최적화 연구)

  • Jang, Myeong-Eon;Kim, Sang-Man;Han, Kyu-Hong;Yeo, Seung-Tai
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.225-232
    • /
    • 2013
  • In this paper, the study was conducted on the subject of the hybrid electric vehicles used by the military, and optimized the propulsion system for fuel economy considering energy supply to the mission equipments. For the analysis of the vehicles, a method based on the geometry and some assumptions was applied with basic vehicle dynamics. The sources of energy supply in the military hybrid electric vehicles are an engine, a battery and an ultra-capacitor. The optimal operation point among an engine, a battery and an ultra-capacitor can be found by minimizing energy consumption of driving power train and mission equipments. In the study, it was possible to find the optimal propulsion system by comparing fuel efficiency of the vehicles during the driving cycle.

A Study on Hydraulic Stable Analysis of The Natural Small River (친환경 소하천의 수리적 안정성 분석에 관한 연구)

  • Kim, Tae-Kyoung;Rhee, Kyoung-Hoon;Sun, Byoung-Jin;Choi, Cheong-Ho
    • Journal of Environmental Impact Assessment
    • /
    • v.16 no.3
    • /
    • pp.187-194
    • /
    • 2007
  • It started road constructions around river in 1990s. These maintenances concentrate on city river. Because river lives no living things and men don't come near there. But in spite of these river environment go to rack, river maintenances still keep on using preexistence method since 1990s. Only a part of city river environment maintenances consider environmental ability of passive river, river maintenance of a purpose of flood control still don't consider in the concrete. Because propulsion device that consider environment ability of passive river and possible application techniques don't complete. In accordance, A natural river maintenance needs absolutly a series of river projects. Because a natural river maintenance prevents a damage of environment ability. This study is to assume the flood really happened and to carry out the flood damage simulation needed in overflow simulation about the inundated zone. Also, This study examine unstable part about the hydraulic characteristic as velocities, stream power, shear, hydraulic depth, flow area in basin. And this study applied the HEC-RAS(river analysis system) model to predict flood overflow in youngsan river basin. Project flood is used the return period 100 year and inputed data that was calculated in intensity figures of illumination.

Optimal Design of Nonuniform Transmission Lime Sections for Wide-Band Impedance Matching (광대역 임피이던스정합용 불균일군차선로의 최적설계)

  • 박송배
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.11 no.6
    • /
    • pp.38-43
    • /
    • 1974
  • A design problem is studied for a nonuniform transmission line (NUTL) section to be inserted between an arbitrary source impedance and an arbitary load impedance for the purpose of impedance matching or providing a minimum input reflection coefficient over a frequency ranee as wide as possible. A special class of NUTL's, yet comprehensive enough to include almost all smoothly varying lines, are considered. Power series expansions of the ABCD parameters of such lines are used in the calculation of the input reflection coefficient. The design problem is formulated as a nonlinear programming problem withnonlinear constraints and is solved by a combined use of the sequential unconstrained minimization technique and tile Fletcher-Powell method. As a result, a line section was obtained which shows a marked improvement over any one hitherto published as a wide-band impedance matching device.

  • PDF

Analysis of th estress intensity factor of mode I crack in a finite width plate with variable thickness (두께가 變化하는 有限幅板材에서의 모우드 I 龜裂 應力擴大係數 解析)

  • 양원호;방시항
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.1
    • /
    • pp.132-144
    • /
    • 1987
  • This paper presents the theroetical analysis of the crack tip stress intensity factor for a center crack in a finite width plate with variable thickness. The analyses were based on Laurent's expansions of complex stress potentials where the expansion coefficients are determined from the boundary conditions. The perturbation method was employed in numerical calculations. The correction factor F(.lambda.)is given in the form of power series of .lambda. [a numerical formula] where .lambda.=a/w$^{1}$; Dimensionless crack length, .betha.=t$_{2}$/t; Thickness ratio .omega.=w$_{2}$/w$_{1}$; width ratio The correction factor values vary with the width ratio .omega. and the maximum variation occurs around .betha.=1. For the case of .betha.=1 or .betha.=0 (uniform thickness plate0, the correction factor values agree well with Feddersen's formula. In all cases, as .lambda. approaches to 1 (thickness interface), the correction factor values are decreased rapidly for .betha.>1, and increased rapidly for .betha.<1.

Utilizing noise mapping in environmental impact assessment in a downtown development area (도심지 개발사업에 따른 환경영향평가시 소음지도 적용방안에 관한 연구)

  • Lee, Shi-Won;Chang, Seo-Il;Park, Younge-Min;Choi, Jin-Kwon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.535-540
    • /
    • 2005
  • In environmental impact assessment, noise impact assessment usually consists of three stages surveying the existing noise levels by measurements, predicting noise levels induced by construction works and predicting noise levels after the completion of project. When predicting noise level in urban area, this method does not consider acoustic phenomena like multi reflection, diffraction and absorption due to complex topographic configuration of building and terrains. For the purpose, a noise mapping tool is utilized to produce a series of noise maps, which are those for the present, for the works of construction and for the future. For accurate noise mapping, acoustical and topographic information is essential. Standard sound power levels and directivities of various construction equipments are required and scheduling of construction processes and locations of the equipments should be provided. In the case of exceeding legal limit, mitigation measures are applied to satisfy the legal limits and subsequent noise map is obtained and checked.

  • PDF

Optimum Locations of Passe Conductor Loops for Magnetic Field Mitigation of Transmission Line using GA (유전 알고리듬을 이용한 송전선로 자계 저감용 도체루프의 최적 위치 선정)

  • Shin Myong-Chul;Kim Jong-Hyung
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.5
    • /
    • pp.234-241
    • /
    • 2005
  • The performance of passive conductor loop (hereinafter 'loop') method which is used to mitigate the magnetic field around overhead power transmission line is dependent on its configuration and installed location, which are affected by installation conditions of the loops such as objective areas and levels of magnetic field mitigation. Thus, because the design problem of loops is difficult and cumbersome by variety of their configuration and complexity of magnetic coupling mechanism, it is need to be formulated as a computer-based optimum problem to determine the most effective and reasonable loop model satisfying the installation conditions. In this paper, the optimum locations of the multi-wired multiple loops including series reactance compensations are searched by using the genetic algorithm (GA) to mitigate effectively the magnetic fields of relatively near points or far points from transmission line at Am height, and the magnetic fields mitigation characteristics of each loop are analyzed in the view of magnitude, direction and phase of cancellation fields by polarized vector concept to identify their adequacy and rationality for the installation objectives.

A Study on the Characteristics of HTS Cable System Operation and Cooling Load in a Load Unbalance (불평형 부하에서의 초전도케이블 운전 및 냉각부하 특성에 관한 연구)

  • Sohn, S.H.;Lim, J.H.;Yang, H.S.;Choi, H.O.;Ma, Y.H.;Kim, D.L.;Ryoo, H.S.;Ryu, K.W.;Hwang, S.D.
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.397_398
    • /
    • 2009
  • Demonstrations to deploy high temperature superconducting (HTS) cable to the real gird are actively carried out throughout the world. Power utilities have an interest in the inherent advantage of the HTS cable system, and achieve the expected results from the series of verification test. To embody the reliability in the phenomenon occurred commonly in three-phase system, we simulate the load unbalance. A 22.9 kV large scale HTS cable system with the specification of 100 m-long, 50 MVA capacity has been tested with up to 30% unbalance rate. To evaluate the effect of AC loss increase due to the unbalanced load, the cooling loads are measured by the calorimetry method. In this paper, the correlation between AC loss and load unbalance is described and investigated precisely.

  • PDF

Analysis on the Hot-spot Temperature Location of a 24MVA Cast Resin Transformer by FEM (FEM을 이용한 24MVA 몰드변압기의 Hot-spot 위치 분석 연구)

  • Kim, Yong-Bae;Ha, Jung-Woo;Shin, Pan-Seok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.9
    • /
    • pp.26-32
    • /
    • 2012
  • This paper calculates the core and copper losses as heating sources of a 24MVA cast resin transformer, and analyzes the thermal distribution of the transformer to find out its hot-spot area by FEM program. Since the winding of the transformer is composed with many series and parallel circuits, the analyzing model of the winding is simplified and modelled by axi-symmetric domain. As the results, the maximum temperature is estimated by $137^{\circ}C$ in the upper part of the low-voltage winding. The maximum temperature has discrepancy of approximately $10^{\circ}C$, which is able to be considered as an acceptable error range in the design stage of power transformers. For the overall pattern of the temperature distribution is almost same as test results, the analyzing method can be a useful tool to find out a hot-spot area of the winding.