경전철 시험선용 전력공급시스템 설계 (The design of the traction power supply for the test line of Light Rail Vehicle)

  • 김국진;백병산;전용주;정상기;김남규
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2001년도 추계학술대회 논문집
    • /
    • pp.322-328
    • /
    • 2001
  • In the electric railway systems, it is very important that we should design the system configuration, location and power capacity of substation. This paper presents the results of system configuration and system design of the DC traction power supply for the test line of Light Rail Vehicle. The voltage fluctuation of train and the power capacity of substation are calculated by computer simulation using the nodal equation, K.C.L/K.V.L, Ohm's law and superposition theory.

  • PDF

경량전철 전력공급시스템의 용량 산정에 관한 연구 (A Study on Capacity Calculation of Power Supply System for Light Rail Transit)

  • 백병산;서광덕;김종구
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 추계학술대회 논문집
    • /
    • pp.696-703
    • /
    • 2000
  • This paper describes the capacity calculation of power supply system for light Rail Transit Three factors are considered for the design i.e. substation arrangements, line configuration and substation power capacity. In this study, we considered all of them for capacity calculation of power supply system for LRT. At first DC-fed-traction system is introduced on an outline, a characteristics of train and fed network, and design method of substation arrangements. Optimal design procedures are described, and program for capacity calculation of the system is presented. In addition, the computer simulated results are computed with the conventional simple calculation method.

  • PDF

철도용 무선전력전송시스템의 급전선로와 레일유기전압의 관계 (Relation between Induced Voltage of Rail and Feeding Line of Wireless Power Transfer System for Railway Application)

  • 김재희;박찬배;정신명;이승환;이병송;이준호;이수길
    • 한국철도학회논문집
    • /
    • 제17권4호
    • /
    • pp.228-232
    • /
    • 2014
  • 철도의 무선전력전송 시스템을 구현하는데 있어 급전선로에서 생성된 자기장은 레일에 유기전압을 형성한다. 레일의 유기전압은 궤도회로의 동작 및 안전사고에 영향을 줄 수 있기 때문에 최소화하는 것이 필요하다. 본 논문에서는 3가지 무선전력전송 선로에 대해서 레일에 형성되는 유기전압의 관계를 시뮬레이션을 통하여 살펴보고 레일 유기전압을 줄이기 위한 급전선로의 자기장 분포를 제시한다.

Power Quality Warning of High-Speed Rail Based on Multi-Features Similarity

  • Bai, Jingjing;Gu, Wei;Yuan, Xiaodong;Li, Qun;Chen, Bing;Wang, Xuchong
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.92-101
    • /
    • 2015
  • As one type of power quality (PQ) disturbance sources, high-speed rail (HSR) can have major impacts on the power supply grid. Providing timely and accurate warning information for PQ problems of HSR is important for the safe and stable operation of traction power supply systems and the power supply grid. This study proposes a novel warning approach to identify PQ problems and provide warning prompts based on the monitored data of HSR. To embody the displacement and status change of monitored data, multi-features of different sliding windows are computed. To reflect the relative importance degree of these features in the overall evaluation, an analytic hierarchy process (AHP) is used to analyse the weights of multi-features. Finally, a multi-features similarity algorithm is applied to analyse the difference between monitored data and the reference data of HSR, and PQ warning results based on dynamic thresholds can be analysed to quantify its severity. Cases studies demonstrate that the proposed approach is effective and feasible, and it has now been applied to an actual PQ monitoring platform.

열차의 효율적 운영을 통한 동력비 절감방안에 관한 연구 - 서울메트로를 중심으로 - (Studies on Power Cost Reduction through Efficient Operation of Railway Vehicles Based on Seoul Metro)

  • 정일봉;박정수;김후규
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.792-800
    • /
    • 2007
  • The annual power cost for Seoul metro operations is about 65.5 billion won, of which rail motors account for 60% among total power consumptions. It is expected that the power consumption would increase because of global warming, future high electric equipments demands, etc. To reduce these consumptions, it is necessary to analyze the transportation demands of passengers, arrange the power-saving driving environments, respond flexible vehicles service, and improve how to drive vehicles. These method to reduce power consumption for rail motors can lead to improve the Seoul metro management. In this research, the improvement plan is derived by collecting and analyzing the data for total 33 power consumptions factors, screening top 10 factors by priority and impact, establishing each hypothesis to execute correlation and recursion analyses. As a result of 4 items research among top 10 affected factors, the power consumption for rail motors in 2006 is effectively reduced; the power usage is down with 13,870 kwh, from 531,539 kwh to 517,669 kwh, and the cost is down with 1,026 million won, from 39, 334 million won to 38,308 million won.

  • PDF

Alternate Energy: Gravity Powered Rail Transportation Systems

  • Bojji, Rajaram
    • International Journal of Railway
    • /
    • 제2권1호
    • /
    • pp.22-29
    • /
    • 2009
  • A simple pendulum shows how efficient gravity is in recovering energy. Any transportation is a linearly oscillating system; every load gains kinetic energy, but loses the same to come to a stop. The Gravity Power Towers comprise of a set of vertically moving heavy masses coupled, through microprocessor controlled continuously variable gear and cable system, to a horizontally rolling unit on wheels either on rail or road. The heavy masses move vertically up against gravity gaining potential energy while stopping a moving mass; move down under gravity force, giving out energy. The Tower thus accelerates or sustains the speed a rolling unit, and while decelerating, recover the kinetic energy. Speeds of 360 kmph can be attained. Recovery of energy varies from 98.5-70%; the longer the distance between stops, the lesser is recovery. The economical, omnipresent & eternal Gravity Power grants energy independence to many a nation. Global warming reduces.

  • PDF

AT급전방식에서 코팅재에 의한 접촉전력에 대한 연구 (A Study on the Contact Power by Coating Material of Spray in AT Feeding Method)

  • 김민석;김민규;박용걸;이종우
    • 전기학회논문지
    • /
    • 제60권1호
    • /
    • pp.85-92
    • /
    • 2011
  • Main characteristic in railroad is the guided movement of the wheel by the track through a metal-to-metal contact, conferring to the rail vehicle a single degree of freedom. There are defects such as head check, shelling, corrugation, squats etc in surface of the rail by interface between the wheel and rail. These defects bring about reducing the life-cycle of rails and track components and increasing noises. In case of bad conditions, it is possible to happen to full-scale accident such as derailment. Recently, the track capacity has been increased for increasing speed and operation efficiency. So, maintenance and indirect cost have been increased. Currently, a coating method of rail construction is proposed by using the ceramics in Korea. Rails are used as the earth in electrical railroad systems. Currently traction return current is flowed through wheels of trains. In case of rails coated, problems are caused in the contact power between wheel and coating material of spray. In this paper, electric model is presented in the AT feeding method. In case of rails coated, electric model is presented. Also, standard resistance of the ceramic is demonstrated by contact power between wheel and coating material of spray.

Rail-to-Rail 입력단과 출력단을 갖는 3 V CMOS 연산증폭기의 최적 설계에 관한 연구 (A Study on the Optimum Design for 3 V CMOS Operational Amplifier with Rail-to-Rail Input Stage and Output Stage)

  • 박용희;황상준;성만영;김성진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1120-1122
    • /
    • 1995
  • This paper presents a 2-stage, simple, power-efficient 3V CMOS operational amplifier and its equation based design optimization. Because of its simple structure, it is very suitable as a VLSI library cell in analog/digital mixed-mode systems. The op-amp, which contains a constant-$g_m$ rail-to-rail input stage and a simple feedforward class-AB rail-to-rail output stage, is analyzed and the results are presented in the form of design equations and procedures, which provide an insight into the trade-offs among performance requirements. The results of SPICE simulations are shown to agree very welt with the use of design equations.

  • PDF

A Rail-to-Rail Input 12b 2 MS/s 0.18 μm CMOS Cyclic ADC for Touch Screen Applications

  • Choi, Hee-Cheol;Ahn, Gil-Cho;Choi, Joong-Ho;Lee, Seung-Hoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제9권3호
    • /
    • pp.160-165
    • /
    • 2009
  • A 12b 2 MS/s cyclic ADC processing 3.3 Vpp single-ended rail-to-rail input signals is presented. The proposed ADC demonstrates an offset voltage less than 1 mV without well-known calibration and trimming techniques although power supplies are directly employed as voltage references. The SHA-free input sampling scheme and the two-stage switched op-amp discussed in this work reduce power dissipation, while the comparators based on capacitor-divided voltage references show a matched full-scale performance between two flash sub ADCs. The prototype ADC in a $0.18{\mu}m$ 1P6M CMOS demonstrates the effective number of bits of 11.48 for a 100 kHz full-scale input at 2 MS/s. The ADC with an active die area of $0.12\;mm^2$ consumes 3.6 m W at 2 MS/s and 3.3 V (analog)/1.8 V (digital).

비접지 급전시스템에서의 레일전위상승과 누설전류 계산 (Calculation methods for the rail potential rise and the stray current in the ungrounded DC traction system)

  • 정상기;박현준;권삼영;배창한
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.631-635
    • /
    • 2006
  • DC traction power system is operated ungrounded to minimize the stray current. This causes rail potential increase and makes hazardous condition to the person in touch with running rails. To prevent the hazardous condition, maximum allowable limits on rail potential rise are set by regulations in advanced foreign countries. In this paper, the simplified calculation methods for the rail potential rise and the stray currents are discussed.

  • PDF