• 제목/요약/키워드: Power quality improvement

검색결과 577건 처리시간 0.027초

Power Flow Control of Grid-Connected Fuel Cell Distributed Generation Systems

  • Hajizadeh, Amin;Golkar, Masoud Aliakbar
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권2호
    • /
    • pp.143-151
    • /
    • 2008
  • This paper presents the operation of Fuel Cell Distributed Generation(FCDG) systems in distribution systems. Hence, modeling, controller design, and simulation study of a Solid Oxide Fuel Cell(SOFC) distributed generation(DG) system are investigated. The physical model of the fuel cell stack and dynamic models of power conditioning units are described. Then, suitable control architecture based on fuzzy logic and the neural network for the overall system is presented in order to activate power control and power quality improvement. A MATLAB/Simulink simulation model is developed for the SOFC DG system by combining the individual component models and the controllers designed for the power conditioning units. Simulation results are given to show the overall system performance including active power control and voltage regulation capability of the distribution system.

Three-Phase Hybrid Shunt Filters for Power Quality Improvement

  • Bhuvaneswari, G.;G.Nair, Manjula
    • Journal of Power Electronics
    • /
    • 제7권3호
    • /
    • pp.257-264
    • /
    • 2007
  • Active power filters can be cost-effective for use in practical systems with the insertion of a few passive elements in shunt or series configuration. The resulting hybrid filters can be designed to provide dominant lower order harmonic elimination and reactive power support by the passive elements so that the burden on the active filter counterpart is reduced. In this paper, the rate reduction in the shunt active filter is estimated when it is connected in parallel with suitable passive tuned harmonic filters. The active filtering system is based on an appropriate control scheme. The simulation and the experimental results of the shunt active filter, along with the estimated value of reduction in rating, show that the hybrid shunt filtering system is quite effective in compensating for the harmonics and reactive power, in addition to being cost-effective.

전기철도 차량기지 변전소의 실시간 무효전력/역률 보상설비 적용에 따른 전력품질 개선에 관한 연구 (A Study on Improving Power Quality by Real-time Reactive Power/Power Factor Compensating Equipment at Substation in Marshalling Yard)

  • 박수철;송중호
    • 조명전기설비학회논문지
    • /
    • 제20권10호
    • /
    • pp.58-67
    • /
    • 2006
  • 본 논문에서는 전기철도 차량기지 변전소의 전력품질을 개선하기 위한 실시간 무효전력/역률 보상설비를 제안하였으며 실제 차량기지에 적용하기 위한 최적의 용량을 제시하였다. 이를 위하여 현재 상용화된 여러 종류의 실시간 무효전력/역률 보상설비를 소개하였고 이 중에 전기철도 차량기지 변전소의 부하 특성에 가장 적합한 보상설비인 SVG(Static Var Generator)를 제시하였다. 제시된 SVG는 PSIM을 사용하여 간이 모의 시스템으로 구현되었으며 이를 통한 기본적인 보상원리와 모의 결과를 기술하였다. 실제 차량기지에 적용하기 위한 최적의 용량 설계는 실제 측정된 차량기지 변전소의 전력품질 데이터를 기초로 설계되어 졌으며 보상효과 및 경제적인 측면이 고려된 용량으로 제시되었다. 최종적으로 전압형 인버터와 직류 커패시터로 구성된 실시간 무효전력/역률 보상설비를 통한 실제 전기철도 차량기지 변전소의 전력품질 개선에 대하여도 기술되었다.

불평형 및 비선형부하 시 전력품질 향상을 위한 독립형 인버터의 전압제어 기법 (Voltage Control of Stand-Alone Inverter for Power Quality Improvement Under Unbalanced and Non-linear Load)

  • 이우종;조종민;차한주
    • 전기학회논문지
    • /
    • 제65권4호
    • /
    • pp.567-575
    • /
    • 2016
  • This paper proposed the voltage control of stand-alone inverter for power quality improvement under unbalanced and non-linear load. The 3-phase DC-AC inverter controls CVCF(Constant Voltage Constant Frequency) and selective harmonic eliminate method in stand-alone mode by PR controller, and the stand-lone inverter supplies stable sinusoidal voltage to balanced, unbalanced and non-linear loads. The total harmonic distortion(THD) of line-to-line load voltage($V_{LL}$) is 1.2% in the balanced load. THD of $V_{LL}$ is reduced from 5.2% to 1.4% and 6.7% to 3.5%, respectively unbalanced and non-linear load. The stand-alone inverter can be supplies sinusoidal balanced voltage to unbalanced load because the voltage unbalanced factor(VUF) of $V_{LL}$ is reduced from 5.2% to 1.4% in the unbalanced load. Feasibility of control method for a stand-alone inverter will be verified through 30kW stand-alone inverter system.

전기철도 고압배전시스템의 공급신뢰도 향상 방안 연구 (Improvement Method of Supplying Reliability on the Electric Railway Power Distribution System)

  • 김영선;창상훈;김왕곤
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.682-687
    • /
    • 2005
  • High quality power supplying of power distribution system in electric railway system is the important function. Power feeding system is complicated witch is compose with distribution line, circuit break, protection facilities and so on. Among this components, role of substation is most important for elevation of reliability in electric power system. Therefore, the enhanced reliability considering the preventive inspection, repair work, replacement is necessary. In this study, a proposed the enhanced reliability method through a calculation of fault probability in power feeding system.

  • PDF

결정결합 방법을 이용한 전력외란 신호의 식별 (Power Quality Disturbance Classification using Decision Fusion)

  • 김기표;김병철;남상원
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 제13회 신호처리 합동 학술대회 논문집
    • /
    • pp.915-918
    • /
    • 2000
  • In this paper, we propose an efficient feature vector extraction and decision fusion methods for the automatic classification of power system disturbances. Here, FFT and WPT(wavelet packet transform) are und to extract an appropriate feature for classifying power quality disturbances with variable properties. In particular, the WPT can be utilized to develop an adaptable feature extraction algorithm using best basis selection. Furthermore. the extracted feature vectors are applied as input to the decision fusion system which combines the decisions of several classifiers having complementary performances, leading to improvement of the classification performance. Finally, the applicability of the proposed approach is demonstrated using some simulations results obtained by analyzing power quality disturbances data generated by using Matlab.

  • PDF

PQM 및 PQMS 성능검증을 위한 실증시험 (The field-test of Power Quality Meter and Power Management System in order to verify the performance)

  • 최선규;송일근;권태호;한재욱
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.235-239
    • /
    • 2005
  • This paper gives a field-test method and result of PQM(Power Quality Meter) and PQMS(Power Quality Management System). The field-test was carried out as our own method. So, the test method has several kinds of improvement in this paper because it is first time to try the field-test of the equipment. However, we expect that the test result of PQM & PQMS has been used as a reference data which makes a scheme of evaluating performance of the equipment that has been used or is developed.

  • PDF

Voltage sag compensator of a high and precise quality for unbalanced three phase power system

  • Park, Hyen-Young;Oh, Se-Ho;Lee, Kyo-Sung;Kim, Do-Hun;Kim, Yang-mo
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -3
    • /
    • pp.1394-1397
    • /
    • 2002
  • High electronic equipments for demand improvement and efficiency are requested the power superior quality. The compensation system of power quality is processing actively. We propose to a series voltage compensator and control algorithm using pid control in unbalanced three- phase power system when voltage sag occurs.

  • PDF

S-transform을 이용한 배전계통의 이벤트와 변동 판별 알고리즘 개발 (Development of the Discrimination Algorithm for Event and Variation in Distribution System Using S-transform)

  • 이순정;서훈철;김철환
    • 전기학회논문지
    • /
    • 제61권5호
    • /
    • pp.657-663
    • /
    • 2012
  • Recently, by increasing of devices which are sensitive to power quality, the deterioration of power quality has been accelerated. For this reason, the social and economic losses are increased. So not only correct measurement and evaluation, but also countermeasure for improvement of power quality is surely necessary for both electric power supplier and consumer. In this paper, the discrimination algorithm for events and variation occurred in distribution systems using S-transform is proposed. Firstly, we review for events and variations that occur in distribution system. Next, we simulate events and variations on various conditions using ElectroMagnetic Transient Program(EMTP). For the simulation, the IEEE 13 Node Test Feeder and KEPCO's distribution system is modeled. Finally, for the analysis, a modified wavelet transform known as S-transform is adopted to find out the characteristics of each events and variations.

전기전자 기기의 노이즈 패턴 분석에 의한 노이즈 개선 대책 (Noise Improvement Countermeasure by Noise Pattern Analysis for Electrical and Electronic Equipment)

  • 조대훈;이기식
    • 전기학회논문지
    • /
    • 제66권1호
    • /
    • pp.194-202
    • /
    • 2017
  • In this study, we measured and analyzed electrical noise signals present in devices and systems operated in industrial facilities. Based on the analytic findings, we studied the most effective improvement measures for eliminating such noise signals. Leakage current and ground current generate data interferences in communication systems, and therefore we measured leakage current and ground current. We also measured and analyzed electrical noises in power systems to predict noise pathways and interference routes. Furthermore, we proposed the most effective and reliable improvement measures for blocking off various noise signals and safely eliminating them by improving the internal wiring of the facilities and grounding systems. As a final step, we conducted the proposed improvement measures and confirmed that they helped to improve the operations of the device sand systems in service by re-measuring electrical noise signals and comparing them with those measured before the proposed improvement measures were implemented.