• Title/Summary/Keyword: Power quality compensate

Search Result 105, Processing Time 0.027 seconds

3-Phase Hybrid Series Active Power Filter with Instantaneous Voltage Fluctuations Compensation (순간전압변동 보상 기능을 갖는 3상 하이브리드형 직렬 능동전력필터)

  • 한석우;최규하
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.6
    • /
    • pp.544-551
    • /
    • 2000
  • In this paper, 3-phase hybrid series active power filter for compensate current harmonics, voltage drop and unbalanced voltage in the network presented. The proposed system is implemented with a space vector modulation voltage source inverter and a high pass filter connected in parallel to the power system. Here the load is six-pulses thyristor rectifier. The phase angle detected in order to generation reference voltage at load terminal is synchronized with the positive sequence component of the unbalanced source by using symmetrical component transformation. The proposed system has an function harmonic isolation between source and load, voltage regulation, and unbalance compensation. Therefore, what the power system is improved quality, the source current is maintained as a nearly sinusoidal waveform and the load voltage is regulated with a rated voltage regardless of the source variation condition. To verify the validity of the proposed compensating system, the computer simulation and experiment are carried out.

  • PDF

Dynamic Voltage Restorers using Improved Voltage Sag and Phase Detection Algorithm (개선된 전압 Sag 및 위상 검출기법에 의한 동적전압보상시스템)

  • Lee, J.Y.;Han, W.D.;Song, Y.H.;Son, J.G.;Joen, H.J.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.185-188
    • /
    • 2005
  • The recent growth in the use of impactive and nonlinear loads, electronic devices sensitive to power quality has caused many power quality problems. Dynamic voltage restorers(DVR) are known as the best effective and economic means to compensate for power quality problems(especially, voltage sag and swell). In this paper, we addresses the detecting algorithms of an voltage sag and phase for operating DVR. Experimental results are included to illustrate the efficacy of the proposed algorithm.

  • PDF

Design of Voltage Controller of DVR based on DSP (DSP를 기반으로한 DVR의 전압제어기 구현)

  • Lee won-sun;Kim soo-gon;Lim Byung-Kuk;Jeon hee-Jong
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.566-569
    • /
    • 2004
  • The recent growth in the use of impactive and nonlinear loads, electronic devices sensitive to power quality has caused many power quality problems. Recently, in power system, not only the reliability of the power supply but also the DVR(Dynamic Voltage Restorer) are being studied more and more. The DVR is a series compensator which can instantaneously compensate a voltage variation in supply side, and is a more effective than a existing UPS(Uninterruptible Power Supply) which can be only used in limited range of loads such as single load. Hence, in this paper, a study of inverter side L-C filter output Voltage for DVR is discussed.

  • PDF

Grid-interactive Small Battery Energy Storage System with High Power Quality and Demand Side Management (전력품질 개선 및 부하 분담 기능을 갖는 계통 연계형 소규모 에너지 저장 시스템)

  • Ko Sung-Hun;Shin Young-Chan;Lee Seong-Ryong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.8
    • /
    • pp.387-394
    • /
    • 2005
  • This paper deals with the grid-interactive small battery energy storage system, which aims at the integration o( power quality improvement and demand side management. The main purpose of the proposed system is to achieve the peak power cutting and to compensate the current harmonics and reactive power at the point of installation on power distribution for residential homes. paper deals with the grid-interactive small battery energy storage system, In this paper, the basic principle and control algorithm is analyzed, theoretically and the design methodology of the system is discussed. To verify the proposed system, a comprehensive evaluation with theoretical analysis, simulation and experimental results for 1 KVA load capacity is presented.

Single-Phase Series Type Quasi Z-Source Voltage Sag-Swell Compensator for Voltage Compensation of Entire Region (전 영역의 전압보상을 위한 단상 직렬형 Quasi Z-소스 전압 Sag-Swell 보상기)

  • Eom, Jun-Hyun;Jung, Young-Gook;Lim, Young-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.322-332
    • /
    • 2013
  • Conventional single-phase series quasi Z-source voltage compensator can not compensate for voltage sag less than 50% that frequently occurs in the industrial field. In this study, single-phase series quasi Z-source voltage sag-swell compensator which can compensate the voltage variation of entire range is proposed. The proposed system is composed of two quasi Z-source AC-AC converters connected in series with output terminal stage. Voltage sag less than 50% could be compensated by the intersection switching control of the upper converter duty ratio and of the upper converter duty ratio. Also the compensation voltage and its flowchart for each compensation mode are presented for entire sag-swell region. To confirm the validity of the proposed system, a DSP(DSP28335) controlled experimental system was manufactured. As a result, the proposed system could compensate for the voltage sag/swell of 20% and 60%. Finally, voltage compensation factor and THD(Total Harmonic Distortion) according to voltage variation and load change were measured, and voltage quality shows a good results.

A Voltage Control Technique of Line-Interactive DVR Using 7-Level H-Bridge Inverter (7-레벨 H-Bridge 인버터를 이용한 Line-Interactive DVR의 전압제어)

  • Kang, Dae-Wook;Hyun, Dong-Seok;Lee, Woo-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.4
    • /
    • pp.705-715
    • /
    • 2007
  • Recently, the interest on power quality has been hot issue because the equipments cause voltage disturbance and have become more sensitive to the voltage disturbance. Additionally, the reseach on power electronic equipments applying to the high power has been increased. This paper deals with Line-Interactive Dynamic Voltage Restorer(LIDVR) system using 7-Level H-Bridge inverter, which is one of the solutions to compensate the voltage disturbance and to increase the power of equipments. The LIDVR has the following advantages comparing to the DVR with the series injection transformer. It has the power factor near to unity under the condition of normal source voltage, can compensate the harmonic current of the load and the instant interruption, and has the fast response. First, the construction, the operation mode and algebraic modeling of LIDVR are reviewed. And then the voltage control algorithm is proposed to get the sinusoidal load voltage with constant amplitude. Finally, simulation and experiment results verify the proposed LIDVR system.

Gird-interactive Current Controlled Voltage Source Inverter System with UPS (UPS를 고려한 계통연계 전류제어형 전압원 인버터)

  • Ko, Sung-Hun;Lim, Sung-Hun;Lee, Su-Won;Lee, Seong-Ryong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.1064-1070
    • /
    • 2007
  • This paper presents a grid-interactive current controlled voltage source inverter (CCVSI) with uniterruptible power supply (UPS), which uses an inner current control loop (polarized ramp time (PRT)) and outer feedback control loops to improve grid power quality and UPS. To reduce the complexity, cost and number of power conversions, which results in higher efficiency, a single stage CCVSI is used. The operation of this system could be divided into the power quality control (PQC) state mode and the UPS state mode. In PQC mode, the system operated to compensate the reactive power demand by nonlinear load or variation in load. In UPS mode. the system is controlled to provide a sinusoidal voltage at the rated value for the load when the gird fail. To verify the proposed system, a comprehensive evaluation with theoretical analysis, simulation and experimental results for 1KVA load capacity is presented.

A Comparative Analysis of Voltage Sag Detecting Techniques for Dynamic Voltage Restorer (동적전압보상기(DVR)를 구성하기 위한 순시전압강하의 검출기법 비교)

  • Shon, Jin-Geun;Suk, Won-Yeob;Park, Jong-Chan;Na, Chae-Dong
    • Proceedings of the KIEE Conference
    • /
    • 2004.07e
    • /
    • pp.10-13
    • /
    • 2004
  • The recent growth in the use of impactive and nonlinear loads, electronic devices sensitive to power quality has caused many power quality problems. Dynamic voltage restorers(DVR) are known as the best effective and economic means to compensate for power quality problems(especially, voltage sag and sewll). In this paper, we adresses the detecting algorithsms and implementation techniques of an voltage sag for operating DVR.

  • PDF

Gird-interactive PV Generation System with Power Quality Control (전력품질개선기능을 갖는 계통 연계형 태양광 발전시스템)

  • Lee, Seong-Ryong;Jeon, Chil-Hwan;Ko, Sung-Hun;Cho, Ah-Ran
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.994-995
    • /
    • 2006
  • This paper presents a grid-connected photovoltaic (PV) system with direct coupled power quality control (PQC) algorithm, which uses an inner current control loop (PRT : polarized ramp time) and outer feedback control loop to improve grid power quality and maximum power point tracking (MPPT) of PV arrays. To reduce the complexity, cost and number of power conversions, which results in higher efficiency, single stage CCVSI (Current Controlled Voltage Source Inverter) is used. The proposed system operation has been divided into two modes (sunny and night). In night mode, the proposed system operates to compensate the reactive power demanded by nonlinear or variation in loads. in sunny mode, the proposed system performs PQC to reduce harmonic current and improve power factor as well as MPPT to supply active power from the PV arrays simultaneously. it is shown that the proposed system improves the system utilization factor to 100% which is generally low for PV system (20%). To verify the proposed system, a comprehensive evaluation with theoretical analysis and simulation results are presented.

  • PDF

Effective Voltage Quality Control under Nonlinear Loads in Islanded Microgrid (독립형 마이크로그리드에서 비선형 부하에 대한 고품질 전압제어)

  • Dam, Hung D.;Lee, Hong-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.6
    • /
    • pp.465-472
    • /
    • 2016
  • A nonlinear load causes harmonic distortion and hampers the performance of other loads or distributed generation (DG) sources connected to the point of common coupling (PCC). This study proposes a new control strategy to reduce harmonic components, such as fifth and seventh harmonics, at the PCC under nonlinear loads in islanded microgrids, which comprise more than two DG sources. The proposed control scheme enables the DG source to share the power commanded by the control center as well as to compensate for the voltage harmonics at the PCC. The reference current is estimated from the voltage harmonics and injecting power; thus, the control scheme is implemented without any additional hardware devices. The simulation and experimental results are presented to verify the effectiveness of the proposed control method.