• Title/Summary/Keyword: Power plant scale

Search Result 383, Processing Time 0.029 seconds

Issues in structural health monitoring for fixed-type offshore structures under harsh tidal environments

  • Jung, Byung-Jin;Park, Jong-Woong;Sim, Sung-Han;Yi, Jin-Hak
    • Smart Structures and Systems
    • /
    • v.15 no.2
    • /
    • pp.335-353
    • /
    • 2015
  • Previous long-term measurements of the Uldolmok tidal current power plant showed that the structure's natural frequencies fluctuate with a constant cycle-i.e., twice a day with changes in tidal height and tidal current velocity. This study aims to improve structural health monitoring (SHM) techniques for offshore structures under a harsh tidal environment like the Uldolmok Strait. In this study, lab-scale experiments on a simplified offshore structure as a lab-scale test structure were conducted in a circulating water channel to thoroughly investigate the causes of fluctuation of the natural frequencies and to validate the displacement estimation method using multimetric data fusion. To this end, the numerical study was additionally carried out on the simplified offshore structure with damage scenarios, and the corresponding change in the natural frequency was analyzed to support the experimental results. In conclusion, (1) the damage that occurred at the foundation resulted in a more significant change in natural frequencies compared with the effect of added mass; moreover, the structural system became nonlinear when the damage was severe; (2) the proposed damage index was able to indicate an approximate level of damage and the nonlinearity of the lab-scale test structure; (3) displacement estimation using data fusion was valid compared with the reference displacement using the vision-based method.

Effects of Pipe Network Materials and Distance on Unused Energy Source System Performance for Large-scale Horticulture Facilities (배관 재질 및 길이에 따른 대규모 시설원예단지용 미활용 에너지 시스템의 성능 평가)

  • Lee, Jae-Ho;Yoon, Yeo-Beom;Hyun, In-Tak;Lee, Kwang Ho
    • KIEAE Journal
    • /
    • v.14 no.4
    • /
    • pp.119-125
    • /
    • 2014
  • This study investigated the effects of pipe network materials and distance on system performance utilizing unused energy sources in large-scale horticulture facility. For this, the modeling was performed with a 100 m long and 100 m wide rectangular shaped glass house having an area of 1ha ($10,000m^2$) using EnergyPlus software. The heat sources considered were air source, geothermal heat, power plant waste heat, sea water heat, and river water. The temperature variation of the fluid with regard to pipe material and distance from the heat source and the resultant heat pump electricity consumptions were calculated. It turned out that the fluid temperature reaching the heat pump increased as the distance from the heat source increased in case of sea water and river water, which have higher temperatures than the surrounding soil, improving the heat pump efficiency. It was vice versa in case of the power plant waste heat. In addition, pipe material of PVC showed the smallest effect on the system performance variation due to the lowest thermal conductivity, compared to PB and HDPE.

Feasibility of Combined Heat and Power Plant based on Fuel Cells using Biogas from Macroalgal Biomass (거대조류 바이오매스로부터 생산된 바이오가스를 사용하는 연료전지 기반 열병합발전의 타당성 검토)

  • Liu, Jay
    • Clean Technology
    • /
    • v.24 no.4
    • /
    • pp.357-364
    • /
    • 2018
  • Studies on the production of biogas from third generation biomass, such as micro- and macroalgae, have been conducted through experiments of various scales. In this paper, we investigated the feasibility of commercialization of integrated combined heat and power (CHP) production using biogas derived from macroalgae, i.e., seaweed biomass. For this purpose, an integrated CHP plant of industrial scale, consisting of solid oxide fuel cells, gas turbine and organic Rankine cycle, was designed and simulated using a commercial process simulator. The cost of each equipment in the plant was estimated through the calculated heat and mass balances from simulation and then the techno-economic analysis was performed. The designed integrated CHP process produces 68.4 MW of power using $36ton\;h^{-1}$ of biogas from $62.5ton\;h^{-1}$ (dry basis) of brown algae. Based on these results, various scenarios were evaluated economically and the levelized electricity cost (LEC) was calculated. When the lifetime of SOFC is 5 years and its stack price is $$225kW^{-1}$, the LEC was 12.26 ¢ $kWh^{-1}$, which is comparable to the conventional fixed power generation.

The Analysis of Active Power Control Requirements in the Selected Grid Codes for Wind Farm

  • Kim, Mi-Young;Song, Yong-Un
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1408-1414
    • /
    • 2015
  • The renewable energies such as photovoltaic power, wind power and biomass have grown to a greater extent as decarbonization techniques. The renewable energies are interconnected to power systems (or electrical grids) in order to increase benefits from economies of scale, and the extra attention is focused on the Grid Code. A grid code defines technical parameters that power plants must meet to ensure functions of power systems, and the grid code determined by considering power system characteristics is various across the country. Some TSO (Transmission System Operator) and ISO (Independent System Operator) have issued grid code for wind power and the special requirements for offshore wind farm. The main purpose of the above grid code is that wind farm in power systems has to act as the existing power plants. Therefore wind farm developer and wind turbine manufacturer have great difficulty in grasping and meeting grid code requirements. This paper presents the basic understanding for grid codes of developed countries in the wind power and trends of those technical requirements. Moreover, in grid code viewpoint, the active power control of wind power is also discussed in details.

Real Option Analysis for Medium-scale CHP Plant Investment with Volatile Electricity Prices (실물옵션을 이용한 소형열병합발전의 경제성 평가 : 전력가격 변동성을 고려하여)

  • Park, Hojeong;Jang, Chulho
    • Environmental and Resource Economics Review
    • /
    • v.16 no.4
    • /
    • pp.763-779
    • /
    • 2007
  • The combined heat-and-power (CHP) plant is recently suggested as an effective resolution in response to recent rising oil prices and the Kyoto Protocol. This research provides a model for economic appraisal to evaluate CHP investment. Real option model is developed to incorporate a case where the investment is irreversible and underlying revenue is stochastic. The analysis shows that power plant capacity more than 40 Gcal makes CHP investment profitable while the results may vary 10 modest level with respect to investment cost, heat sales price and discount rate.

  • PDF

Development of Techno-Economic Evaluation Model for CCS (Carbon Capture & Sequestration) (CCS (Carbon Capture & Sequestration) 기술·경제성 평가 분석)

  • Lee, Ji Hyun;Kwak, No-Sang;Lee, Dong Woog;Shim, Jae-Goo;Lee, Jung Hyun
    • Journal of Climate Change Research
    • /
    • v.7 no.2
    • /
    • pp.111-120
    • /
    • 2016
  • In this study, Techno-economic evaluation model for carbon capture & sequestration (CCS) technologies are reviewed. Based on a key parameters of Korea's electricity market, performance data of 10 MW-scale post-combustion $CO_2$ capture pilot plant in Boryong station, the cost of $CO_2$ avoided was evaluated followed by international guideline suggested by IEA CCS costing methods task force. The result showed that Korea's Electricity cost including CAPEX & OPEX of reference power plant is relatively low compared to OECD nations which lead to a lower CCS cost ($33USD\;t/CO_2$). And future work using newly evaluated CAPEX & OPEX data of power plant with/without CCS is recommended.

Multi-unit Level 1 probabilistic safety assessment: Approaches and their application to a six-unit nuclear power plant site

  • Kim, Dong-San;Han, Sang Hoon;Park, Jin Hee;Lim, Ho-Gon;Kim, Jung Han
    • Nuclear Engineering and Technology
    • /
    • v.50 no.8
    • /
    • pp.1217-1233
    • /
    • 2018
  • Following a surge of interest in multi-unit risk in the last few years, many recent studies have suggested methods for multi-unit probabilistic safety assessment (MUPSA) and addressed several related aspects. Most of the existing studies though focused on two-unit nuclear power plant (NPP) sites or used rather simplified probabilistic safety assessment (PSA) models to demonstrate the proposed approaches. When considering an NPP site with three or more units, some approaches are inapplicable or yield very conservative results. Since the number of such sites is increasing, there is a strong need to develop and validate practical approaches to the related MUPSA. This article provides several detailed approaches that are applicable to multi-unit Level 1 PSA for sites with up to six or more reactor units. To validate the approaches, a multi-unit Level 1 PSA model is developed and the site core damage frequency is estimated for each of four representative multi-unit initiators, as well as for the case of a simultaneous occurrence of independent single-unit initiators in multiple units. For this purpose, an NPP site with six identical OPR-1000 units is considered, with full-scale Level 1 PSA models for a specific OPR-1000 plant used as the base single-unit models.

Feasibility Study for Tidal Power Plant Site in Garolim Bay Using EFDC Model (EFDC모형을 이용한 가로림만의 조력발전 위치 타당성 검토)

  • Shin, Bum-Shick;Kim, Kyu-Han;Kim, Jong-Hyun;Baek, Seung-Hwa
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.23 no.6
    • /
    • pp.489-495
    • /
    • 2011
  • Fossil fuel energy has become a worldwide environmental issue due to its effect on global warming and depletion in its supply. Therefore, the interest in developing alternative energy source has been rising. Ocean energy, especially, has gained strength as an alternative energy source for its unlimited supply with low secondary risks. Among all the ocean energy, the west coast of Korea holds the field of large-scale energy development because of its distinctive tidal range. Tidal power plant construction at the sea may expedite multi development effects such as bridge roles, tourism resource effects and adjustability of flood inundation at the inner bay. This study introduces the validity of tidal power plant construction at Garilim Bay in west coast of Korea by examining anticipated hydraulic characteristics using EFDC model. Through EFDC numerical simulations, the feasibility of Garolim Bay as a tidal power plant field has been proved. And the most effective tidal power plant construction would be to install hydraulic turbine in the west side of bay entrance where ebb current is stronger, and install water gate in the east side of bay entrance where the flood current is superior.

A Study on Application of the Korea Human Scale to Anthropometric Design

  • Lee, Dhong-Ha
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.1
    • /
    • pp.211-217
    • /
    • 2012
  • Objective: The aim of this study is to show a correct application procedure using the compact Korean anthropometric data application program called Korean Human Scale(KHS) for anthropometric design. Background: The nation-wide anthropometric survey project called 'Size Korea' developed KHS and distributed it to the public on the web site. But some insufficiency of the current web service of KHS misleads the users; they just put their own statue and pick up a meaningless data for a body dimension. Method: This study provides five steps to follow to read appropriate data from KHS for an anthropometric design. Results: As a case study, the depth dimension of the supervisory and control console used in the Korea nuclear power plant was determined following the procedure and compared with the console design guideline recommendation. Conclusion: The supplementary anthropometry table should be added on the web service of KHS for users to read a meaningful data for design. Application: If properly used, the KHS has a lot more potential application area than users can expect such as in control center design area.

Investigation of Combustion Characteristics of Low Calorific Value Syn-gas Using Lab-scale Pressurized Oxy-Combustion System (실험실 규모의 가압 순산소 연소 시스템을 이용한 저열량 합성가스의 연소특성 분석 연구)

  • Kim, Donghee;Lee, Youngjae;Yang, Won
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.65-68
    • /
    • 2015
  • Agreeable to the latest enviromental problem, CCS(Carbon Capture&Storage) technology is more significant. As these issues, Oxy-Combustion is one of the technology that realize the CCS technology and large scale field test proceeding at other places. The aims of this research were to evaluate the combustion characteristics of pressurized oxy-combusition that is attract attention as the next generation power plant. The experiments were conducted using a laboratory-scale pressuized oxy-combustor. The fuel used was low calorific value syn-gas that is mainly composed of CO(60%), $H_2$(27%). The burner was used co-axial burner, to investigate combustion characteristics, temperature in the reactor and the flue gas compositions were measured.

  • PDF