• Title/Summary/Keyword: Power monitoring

Search Result 2,821, Processing Time 0.031 seconds

A Study on the Interface between DAS and SCADA by using Direct Method (직접연계방법에 의한 DAS-SCADA 연계 연구)

  • Park, So-Young;Shin, Chang-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.5
    • /
    • pp.1154-1163
    • /
    • 2008
  • DAS and SCADA system are main systems, which operate and manage the power system by using computer and communication technology. But DAS and SCADA have been operated independently in Korea, so there was some time delay in the fault handling and live-line work. To improve that problems, studies on the interface between DAS and SCADA have been needed. From November 2005 to December 2007, the pilot project has been performed in KEPCO's branch offices, as a result, direct method will be applied widely all over the country until 2010 because the operation information of substation users want can be transmitted fast and it is possible to control 43RC directly although the expense for direct method is about 1.3 times larger than that for web method. To improve problems revealed during the pilot project, substation object to object communication method is proposed and interface database automatic generation and interface system diagnosis and logging functions are developed. Interface data point and communication data type are defined, substation single line diagram automatic generation or manual editing function, SCADA monitoring and controlling function, log data managing function are developed in SCADA HMI program. It is expecting to reduce the average time for each outage about 33% and to improve the reliability, efficiency of operation, execution of DAS from automatic load transfer under a fault, and to contribute to export project.

The Effects of Scale Growth Inhibition on Water Pipe using Frequency Driver (Frequency Driver를 이용한 냉온수관의 스케일 방지억제효과)

  • Jang, Mi-Jeong;Sung, Il-Wha
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.4
    • /
    • pp.258-266
    • /
    • 2011
  • Scale induced by hardness materials in water must be controled because of it can be result in remarkable damages of pipeline as well as water quality deterioration. Especially hot water system is one of scale management required facility as scale formation can be accelerated by temperature. The scale control performance of frequency driver (FD) was tested instead of existing methods such as chemical, physical and electromagnetic methods which needs chemicals and electric power. Three kinds of pipe coupons were submerged in test water with 500 mg/L of hardness for 33 days and XRD and SEM were analysed for comparing scale formation characteristics of these coupons. Calcite ($CaCO_3$) which came from hardness of water was formed on only cast iron pipe coupon and this coupon showed higher corrosion rate than copper and stainless steel pipe coupon. Hot water circulating system connected cast iron pipe with and without FD was operated with 300 mg/L of hardness water at $50^{\circ}C$ for monitoring of scale formation and water quality with and without FD. XRD showed that FD leaded to magnetite ($Fe_3O_4$) scale which is good scale for preventing corrosion than calcite and SEM image also indicated the scale control effect of FD. Scales of 16% on pipe joint, 14% on pipe length, and 42% on heat exchanger decreased with FD comparing scales of those parts without FD. From the results of water quality, FD reduced crystallization of hardness material without chemical reaction in water and it can indicate that FD is safe and proenvironmental technology for scale reduction.

Feasibility Study on a Defrost Control Method by Using a Photoelectric Sensors (광센서를 이용한 제상제어 방법에 대한 타당성 검토)

  • Jeon, Chang-Duk;Kim, Dong-Seon;Lee, Seung-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3389-3395
    • /
    • 2014
  • Conventional methods, such as the clock time control method and temperature difference control method, for defrost control often encounter mal-defrost and a waste of energy. Therefore, a more efficient method is needed to control defrosting precisely. A photoelectric sensor unit consisting of an emitter and a collector was installed in the front of outdoor heat exchanger. Accurate defrost control was performed by monitoring and using the change in output voltage according to the presence of frost. In this study, experiments were performed to determine if the performance and characteristic curves obtained using the clock time control method can be reproduced using a photoelectric sensor under the heating and defrosting capacity test condition described at KS C 9306. The output voltage of the phototransistor (receiver) and heating capacity, power consumption, and surface temperature of the outdoor heat exchanger, were compared. The results showed that photoelectric sensors can be used as a defrost control method. On-off control timing of the clock time defrosting method was in good agreement with those predicted by the output voltage of the photoelectric sensor.

Recent Developments and Field Application of Foreign Waterworks Automatic Meter Reading (국외 상수도 원격검침시스템의 개발 동향 및 현장 적용 사례 고찰)

  • Joo, Jin Chul;Ahn, Hosang;Ahn, Chang Hyuk;Ko, Kyung-Rok;Oh, Hyun-Je
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.12
    • /
    • pp.863-870
    • /
    • 2012
  • The market trends of automatic meter reading associated with smart water meters were investigated. Also, recent developments and field applications of key technology for automatic meter reading associated with smart water meters were analyzed. Smart water meters have been manufactured mostly in United States and Europe and have been expanded their business to Asia. Integrated water management system combining with the additional functions such as real-time consumption metering, cost notification, water conservation, leak detection, water quality monitoring, and flow control have been operated in automatic meter reading. Both water quality and quantity data measured from smart water meters and sensors were transferred to data concentration units through neighborhood area network, and then were transferred to integrated server through wide area network. The data transfer methods were determined by comprehensively considering urban scale, density of smart water meters, power supply and network topologies. Common data collection methods such as fixed network to data concentation units, vehicles drive by, people walk by, and drone fly by have been applied. The automatic meter reading associated with smart water meters are spread throughout the world, and both water and energy savings result in saving the money and reducing the greenhouse gases emission.

Evaluation on real-time multi-point sensing performance of IoT-based hybrid measurement system (IoT 기반 하이브리드 계측시스템 실시간 다점 측정 성능 평가)

  • Kim, Heonyoung;Kang, Donghoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.543-550
    • /
    • 2018
  • The rapid growth of IoT technology induced by the fourth industrial revolution has resulted in research into various types of wireless sensors, and applications based on this technology are prevalent in many areas. However, among the various sites where this technology is used, railway bridges and tunnels with lengths of tens of kilometers have problems with data acquisition, due to the signal noise induced by the long distance measurement and EMI induced by the high voltage power feeding system, when conventional electric sensors are used. To overcome these problems, many studies on fiber optic sensors have been conducted as a substitute for the conventional electric sensors. However, restrictions on the types of fiber optic sensors have limited their application in railways. For this reason, a hybrid measurement system with IoT based wireless data communication, in which both electric and fiber optic sensors can be applied simultaneously, has been developed. In this study, in order to evaluate the applicability of the hybrid measurement system developed in the previous study, a real-time test for 4 types of measurement environments, which reflect possible railway sites, is performed. As a result, it was confirmed that the signals from both the electric and fiber optic sensors, which were acquired at a remote area in real-time, showed good agreement with each other and that this measurement system has the potential to handle sensors with a sampling rate of 2.5 kHz. In the future, it is expected that the IoT-based hybrid measurement system will contribute to the improvement of structural safety by enabling real-time structural health monitoring when applied to various measurement sites.

Study on the Use of Bracketed Summations of the Peak Ground-motion Acceleration Per Second for Rapid Earthquake Alert Notifications (신속 지진피해통보를 위한 지반가속도의 초당 최대값 구간적산 방법의 활용에 관한 연구)

  • Yun, Kwan-Hee
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.16 no.1
    • /
    • pp.37-45
    • /
    • 2012
  • In an effort to further exploit the peak ground-motion acceleration (PGA) information per second available in real time by the enacted law, bracketed summations of the PGA per second ($BSPGA_k$) for 30 seconds based on the records with a rate of 100 samples were compared with the cumulative absolute velocity (CAV) and earthquake intensities based on a worldwide database of records from small-to-large earthquakes. The CAV, currently in use as an earthquake damage indicator for nuclear power plants due to its strong correlation with the earthquake intensity, has the disadvantage of requiring a massive amount of digital data with a rate of more than 100 samples per second. The comparative study shows that the $BSPGA_k$ is well correlated with the CAV over the wide range of strong ground-motion levels, which suggests that the $BSPGA_k$ is one of the new promising ground-motion parameters especially useful for rapid earthquake alert notifications through an earthquake monitoring network. Based on the domestic database of records from small-to-moderate earthquakes with felt reports, it is also observed that the $BSPGA_k$ is comparable to the CAV and better than the PGA in predicting the intensity by using the correlation relation.

Effect of New Mattress System with Vegetation Base Materials on the Vegetation Coverage of Stream bank (계안 복원을 위한 매트리스형 식생기반재 돌망태 공법의 계안사면 피복효과)

  • Choi, Hyung Tae;Jeong, Yong-Ho;Park, Jae-Hyeon
    • Journal of Korean Society of Forest Science
    • /
    • v.101 no.2
    • /
    • pp.175-184
    • /
    • 2012
  • This study was conducted to develop new mattress systems with vegetation base materials for protecting stream bank and rapid rehabilitation. Vegetation base materials are primarily compounded with fine soil, organic composts and peat moss as plant fibers, a water retainer and a soil improver. Peat moss can usually provide necessary natural fibers and organic materials in soil. Especially, peat moss can absorb up to 25 times its own weight in water and is therefore valued as a water retainer to prevent drying effect of vegetation base materials which can harm the growth of vegetation in mattresses. Normally mattress systems resist the lateral earth pressures or stream power by their own weight. Therefore, filled materials must have suitable weight, compressive strength and durability to resist the loading, as well as the effects of water and weathering. In this project, 100 to 200-mm clean, hard stones were basically specified, and about 50-mm rubbles were also used. Test application of new mattress system carried out in the stream bank of a small stream in the Gwangreung experimental forest, belonging to Korea Forest Research Institute (KFRI) in December 16th, 2006. As a result of the monitoring of vegetation coverage of test application plots (each plot size is 4 by 2 m), the coverage of all plots reached 100% in the end of May, 2007 (approximately 50 days passed after the first gemination of vegetation). The coverage of the plots using big hard stones and organic composts and the plots containing peat moss increased more rapidly. The results show that peat moss is effective to retain soil moisture and establish more sound environment for vegetation gemination.

Data Transmission System from Distant Area Using SD-Card and Ethernet (SD 카드와 이더넷을 이용한 원격지 데이터 전송시스템)

  • Jo, Heung-Kuk
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.381-385
    • /
    • 2010
  • An aging Society solitary life old mans are increasing. The nurses have to visit old mans and must confirm their disease, because they do not act well. It is very difficult to take care old man, because the number of Nurses are small. This problem is solved by collection of data about condition of old mans from long distance. Data communication with Ethernet have benefit to collection of measurement of old man's condition. The Data storage system an long distance place are storaged data and after several day data was transmitted to the DB over the Ethernet. For Miniaturization of such system the system must be OS-less Embedded Ethernet Server system. Such system manages the file management system only with H/W. The Storage device is used SD-card. SD Card is small size and operates with small power. By using 512MB sd memory card, it is possible to storage during 5~6 years, 10 byte of temperature value per second. In this paper, we make a Embedded Ethernet Server using W3100A, Atmega128 MCU and data stroage device using SD-Card. This system operates with O/S-less Embedded Ethernet Server. We talk about file System, Storage and Ethernet. We explained about MCU Atmega128, Interface between LAN LSIand W3100A, Interface between W3100A and Phyceiver RTL8201, data I/O between MCU and SD-Card and File System. We shows the experiment device and result of monitoring.

  • PDF

Development of DAP(Dose Area Product) for Radiation Evaluation of Medical and Industrial X-ray generator (의료 및 산업용 X-선 발생장치의 선량평가를 위한 면적선량계(DAP) 개발)

  • Kwak, Dong-Hoon;Lee, Sang-Heon;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.22 no.2
    • /
    • pp.495-498
    • /
    • 2018
  • In this paper, we propose an DAP system for dose evaluation of medical and industrial X-ray generator. Based on the DAP measurement technique using the Ion-Chamber, the proposed system can clearly measure the exposure radiation dose generated by the diagnostic X-ray apparatus. The hardware part of the DAP measures the amount of charge in the air that is captured by an X-ray. The high-speed processing algorithm part for cumulative radiation dose measurement through microcurrent measures the amount of charge captured by X-ray at a low implementation cost (power) with no input loss. The wired/wireless transmission/reception protocol part synchronized with the operation of the X-ray generator improves communication speed. The PC-based control program part for interlocking and aging measures the amount of X-ray generated in real time and enables measurement graphs and numerical value monitoring through PC GUI. As a result of evaluating the performance of the proposed system in an accredited testing laboratory, the measured values using DAP increased linearly in each energy band (30, 60, 100, 150 kV). In addition, since the standard deviation of the measured value at the point of 4 division was ${\pm}1.25%$, it was confirmed that the DAP showed uniform measurements regardless of location. It was confirmed that the normal operation was not less than ${\pm}4.2%$ of the international standard.

A Design and Implementation of Mobile Logistics Information System (모바일 물류정보시스템 설계 및 구현)

  • Lee, Won-Joo;Lee, Sang-Jun;Lim, Heon-Yong;Kim, Chang-Hyeon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.7
    • /
    • pp.139-146
    • /
    • 2012
  • In this paper, we implement an m-LIS(Mobile-Logistics Information System) for an effective logistics management in consideration of logistics process and work environment. The m-LIS could perform the entire business process every minute and promote the work efficiency by tying up with ERP and POS system. Moreover, this system could enhance the management level of service and supply chain. Due to the reason that the existing logistics business was not computerized and automated, most of operation was accomplished by means of workers experience and convention. This problem brought about both the ineffective management and logistics quality deterioration by weakening the control power of the logistics site. In order to solve this problem, we put focus on providing the real-time operation monitoring environment on the spot, the satisfaction of the efficiency on the spot, and the optimized system by building up the logistics information system. Furthermore, we attest that the new logistics system could properly cope with the increase of the quantity of goods transported owing to stable logistics information support and the market expansion and growth caused by the firm interface between the new ERP and its related system.