• 제목/요약/키워드: Power limit

검색결과 1,454건 처리시간 0.027초

역률개선을 위해 경계전류모드로 동작하는 브리지리스 부스트 컨버터 (Boundary Current Mode Operated Bridgeless Boost Converter for Power Factor Correction)

  • 유병규;이성세;한상규;문건우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 추계학술대회 논문집
    • /
    • pp.90-94
    • /
    • 2003
  • Recently, many nations have released standard such as IEC 1000-3-2 and IEEE 519 which impose a limit on the harmonic current drawn by equipment connected to AC line in order to prevent the distortion of an AC line. Among the wide variety of active methods for improving power factor and harmonic distortion, the boost converter is very effective because it has a continuous line current , small choke filter and high power factor. In high power application, however, the bridge diode loss in the boost converter has made the efficiency lower and the temperature of the board higher. A new approach without bridge diode to make the same characteristics of the conventional boost converter has also been developed. This paper present the comparisons between the continuous current mode(CCM) operated conventional boost converter and the boundary current mode(BCM) operated the bridgeless boost converter for high efficiency and high power factor.

  • PDF

Design of the Electronic Anti-Fouling System for a Wave Energy Converter

  • Lee, Ji-Young;Oh, Jin-Seok
    • 한국항해항만학회지
    • /
    • 제33권7호
    • /
    • pp.501-504
    • /
    • 2009
  • There are many difficulties to supply constant power to marine facilities which operate in the sea. Especially, there is a limit to stand alone power supply systems due to the influence of weather conditions. That's why a hybrid power supply system is required to overcome these problems. This paper will describe an Electronic Anti-Fouling System (EAFS) to maximise the power efficiency for a solar - wave hybrid power generation system. A main factor reducing the efficiency of a Wave Energy Converter (WEC) is due to the attachment of aquatic life forms. Therefore the aim of this research is to develop a simulation programme to enable the design of more efficient EAFS for hybrid power generation systems and to provide valuable data for production of more efficient EAFS.

철도고배 전송선로 분로리액터 설치에 대한 모델링 (A modelling on Shunt Reactors in Railway Power Transmission System)

  • 이종수;이종우
    • 전기학회논문지
    • /
    • 제64권8호
    • /
    • pp.1262-1268
    • /
    • 2015
  • I In power transmission systems, voltage changes continuously as reactive power is whether over supply or shortage. Reactive power produces in generators and consumes in transmission lines, and loads. Voltages at end points of transmission lines rise which is called Ferranti effect. Excessive voltage rising can reduce transmission equipment life, the voltage rising is usually permitted within the limit of 10%~30% excess. Shunt reactors are installed in transmission lines to put a curb on voltage rising. In this paper, we tried to do modelling for shunt reactor configuration types which are no grounding, grounded and grouded neutral reactor. Simulation are carried out for reactor magnitude for compensating transmission line capacitance.

Long-term Radiation Dose Reduction Plan of KHNP

  • Kim, Saeng-Ki;Shin, Sang-Woon;Lim, Byoung-Chan
    • Journal of Radiation Protection and Research
    • /
    • 제28권2호
    • /
    • pp.137-143
    • /
    • 2003
  • Annual radiation dose limit to radiation worker was substantially lowered in Korea by the adoption of 1990 recommendations of the International Commission on Radiation Protection (ICRP 60) in its legislation. On the other hand, radiation management environment in nuclear power plants is getting more worse because of the accumulation of radiation sources inside the system and the frequent need for maintenance according as the operation years of nuclear power plants increase. Therefore, Korea Hydro & Nuclear power Co., Ltd. (KHNP) has established a long-term 10 years plan from 2001 to 2010 for the reduction of radiation dose to workers. The plan is aimed for the reduction of annual dose per unit averaged over 5 years from 0.9 man-Sv in 2001 to 0.75 man-Sv in 2010 by radiation source reduction, equipment/tool improvement or new equipment development for easy maintenance, and the improvement of administration and system.

영전압 스위칭 프로그래머블 전원장치에 관한 연구 (A Zero-Voltage-Switching Programmable Power Supply)

  • 오덕진;임상언;김희준
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권8호
    • /
    • pp.551-556
    • /
    • 2000
  • A zero-voltage-switching(ZVS) programmable power supply employing the ZVS active clamp forward converter is suggested. Through the analysis on operation region of the supply, the constant power region and the maximum current limit region are clearly identified. Furthermore, the duty ratio range corresponding to the variation range of the output voltages and the control scheme at the minimum duty ration region are presented. Finally, in order to vefity the validity of the operation for the proposed power supply, experimental evaluation results obtained on an 1kW prototype power supply for the 198~242VAC input voltage range(220VAC$\pm$10%), the 0~25V output voltage range, and the 100kHz switching frequency are presented.

  • PDF

분산전원이 도입된 배전계통에 초전도한류기 적용시 계통보호 시스템의 영향에 관한 연구 (A Study on the Protection of Power Distribution System with the Distributed Generator and Superconducting Fault Current Limiter)

  • 김명현;김진석;임성훈;김재철
    • 전기학회논문지
    • /
    • 제61권9호
    • /
    • pp.1226-1231
    • /
    • 2012
  • The demand for electrical power has been significantly increased to satisfy the customers. As a result, a power distribution system have been advanced by power system's interconnection, installation of distributed generator(DG) and so on. The improvable power distribution system included the problem of increasable fault current. Superconducting fault current limiter (SFCL) is one of the solutions to limit a fault current. Therefore, to solve the problem of fault current by SFCL, simulation was progressed and the simulation used a PSCAD/EMTDC.

Interleaved Boost-Flyback Converter with Boundary Conduction Mode for Power Factor Correction

  • Lin, Bor-Ren;Chien, Chih-Cheng
    • Journal of Power Electronics
    • /
    • 제12권5호
    • /
    • pp.708-714
    • /
    • 2012
  • This paper presents a new interleaved pulse-width modulation (PWM) boost-flyback converter to achieve power factor correction (PFC) and regulate DC bus voltage. The adopted boost-flyback converter has a high voltage conversion ratio to overcome the limit of conventional boost or buck-boost converter with narrow turn-off period. The proposed converter has wide turn-off period compared with a conventional boost converter. Thus, the higher output voltage can be achieved in the proposed converter. The interleaved PWM can further reduce the input and output ripple currents such that the sizes of inductor and capacitor are reduced. Since boundary conduction mode (BCM) is adopted to achieve power factor correction, power switches are turned on at zero current switching (ZCS) and switching losses are reduced. The circuit configuration, principle operation, system analysis, and design consideration of the proposed converter are presented in detail. Finally, experiments conducted on a laboratory prototype rated at 500W were presented to verify the effectiveness of the converter.

680MW 원자력발전소 증기터빈 발전기의 부하차단 모의시험 (A Simulation Test of Load Rejection for Steam Turbine Generator in a 680MW Nuclear Power Plant)

  • 최인규;정창기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1605-1606
    • /
    • 2007
  • An electrical generator in power plant is driven and maintained its speed at rated by steam turbine. By the way, after synchronization in parallel with the power system, as the steam flow into turbine can not be reduced fast even though the electrical load is lost, the turbine gets into dangerous situation due to the increase of its speed. At this time, the duty of the turbine governor is to limit the speed to its overspeed trip set point by stopping the steam flow as soon as possible, the test of which is called load rejection test. It is introduced in this paper for a field simulation test of generator load rejection to be implemented on the turbine governor in a 680MW nuclear power plant before its startup.

  • PDF

벅-부스트 형 태양전력 조절기의 디지털 제어 (Digital Control for BUCK-BOOST Type Solar Array Regulator)

  • 양정환;윤석택;박성우
    • 한국위성정보통신학회논문지
    • /
    • 제7권3호
    • /
    • pp.135-139
    • /
    • 2012
  • 디지털 제어기를 사용하면 태양전력 조절기의 전력변환 시 아날로그 회로로 구현이 불가능한 전력변환 제어 기법을 적용할 수 있으며 태양전력 조절기의 복잡한 운용 알고리즘을 구현할 수 있다. 디지털 제어기를 사용하여 태양전력 조절기의 입력 등가 임피던스를 저항 특성을 가지도록 정저항 제어하면 단일 정저항 제어기만으로 태양전력 조절기의 전류를 제어를 할 수 있다. 한편, 태양전지는 전압원 영역에서 저항이 큰 폭으로 변하며, 전류원 영역에서 작은 폭으로 변한다. 따라서 태양전력 조절기를 정저항 제어기로 제어하는 경우, 이러한 태양전지의 특성에 적합한 가변 진폭 최대 전력점 추적 기법을 적용하는 것이 유리하다. 그러나 가변 진폭 최대 전력점 추적은 태양전지의 대신호 저항과 소신호 저항을 이용하므로 태양전지가 출력하는 전력량을 계산하여 제한할 수 없다. 본 논문에서는 디지털 제어기를 사용하여 태양전지가 생성하는 최대 전력을 제한하는 운용 알고리즘을 제안하고 모의실험을 통해 디지털 제어기로 제어되는 태양전력 조절기를 검증한다.

복합화력발전소 가스터빈 발전기계통 모델정수 도출 및 검증을 위한 특성시험 (Characteristic Tests on the Gas Turbine Generator System for Determination and Verification of Model Parameters in a Combined Cycle Power Plant)

  • 김종구;유호선
    • 플랜트 저널
    • /
    • 제17권4호
    • /
    • pp.35-40
    • /
    • 2021
  • 본 연구에서는 서인천복합 6호기 가스터빈 발전기계통에 대하여 기술특성시험을 실시하여 모델정수를 도출하고 검증하였다. 발전기 최대/최소 무효전력 한계시험 결과 최대 무효전력 한계는 80 MVar이고, 최소 무효전력 한계는 -30 MVar이다. 발전기는 GENROU 모델을 사용하였고, 계자시정수(T'do)는 4.077 s, 관성정수(H)는 5.461 P.U로 결정하였다. 여자시스템은 ESST4B 모델을 사용, 무부하 2% AVR 스텝시험을 모의하는 방식으로 모델정수를 도출하고 검증하였으며, PSS 모델링은 PSS2A 모델정수로 도출하였고, PSS Off/On일때 측정된 계측 데이터를 모의, 비교하여 검증하였다. 조속기-터빈는 GGOV1 모델을 사용하여 모델정수를 도출하고 검증하였다. PSS/E 시뮬레이션 프로그램을 통해 10% 조속기 스텝시험을 모의하여 결정된 조속기-터빈 모델정수의 수치 안정성을 확인하였다.