• Title/Summary/Keyword: Power integrity analysis

Search Result 325, Processing Time 0.029 seconds

A Study on the Static/Dynamic Stability and the Fatigue Damages for the Worm Gear in the B-Axis Rotary Table of a Mill Turret (복합공구대용 B축 회전테이블 웜 기어의 정/동적 안정성 및 피로에 관한 연구)

  • Kim, Chae-Sil;Kang, Seung-Hee
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.5
    • /
    • pp.107-115
    • /
    • 2014
  • Highly functional mill turrets have been developed and continuously improved to shorten the manufacturing time and enable multiple uses. Among these, a mill turret with B-axis rotary table was developed. The B-axis rotary table should be evaluated for structural integrity. Moreover, its worm and worm gear for transmitting power should be able to endure fatigue damage. Therefore, this article presents a structural analysis of this type of B-axis rotary table and confirms its static stability by comparing the stress results to the allowable stress levels. Next, the dynamic stability of the rotary table was investigated via a mode analysis and a harmonic analysis in a range determined by the results of a modal analysis. Finally, a worm gear set, the main part that drives the rotary table, is analyzed for fatigue and to estimate its lifetime. The results of the fatigue analysis allowed a prediction of the life of the worm gear set. The analytical results show that the B-axis rotary table has good structural integrity.

Automated Analysis Technique Developed for Detection of ODSCC on the Tubes of OPR1000 Steam Generator

  • Kim, In Chul;Nam, Min Woo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.6
    • /
    • pp.519-523
    • /
    • 2013
  • A steam generator (SG) tube is an important component of a nuclear power plant (NPP). It works as a pressure boundary between the primary and secondary systems. The integrity of a SG tube can be assessed by an eddy current test every outage. The eddy current technique(adopting a bobbin probe) is currently the main technique used to assess the integrity of the tubing of a steam generator. An eddy current signal analyst for steam generator tubes continuously analyzes data over a given period of time. However, there are possibilities that the analyst conducting the test may get tired and cause mistakes, such as: missing indications or not being able to separate a true defect signal from one that is more complicated. This error could lead to confusion and an improper interpretation of the signal analysis. In order to avoid these possibilities, many countries of opted for automated analyses. Axial ODSCC (outside diameter stress corrosion cracking) defects on the tubes of OPR1000 steam generators have been found on the tube that are in contract with tube support plates. In this study, automated analysis software called CDS (computer data screening) made by Zetec was used. This paper will discuss the results of introducing an automated analysis system for an axial ODSCC on the tubes of an OPR1000 steam generator.

Fast computation method for the voltage-current analysis on the rectangular power-ground plane (직사각형의 전력-접지층에 대한 전압전류 특성해석을 위한 빠른 계산방법)

  • Suh, Young-Suk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.1
    • /
    • pp.140-145
    • /
    • 2005
  • The existing analytical expression for the voltage between the power and ground plane consist of metal-dielectric-metal board is expressed in the two dimensional infinite series. To reduce the computation time, the two dimensional infinite series is converted to the one dimensional infinite series using the summation formula of Fourier series. We applied these equations to the analysis of voltage between the $9‘{\times}4'$ size power-ground plane. The derived one dimensional infinite series shows the more rapid convergency and the more accurate result than the two dimensional infinite series. This equation can be applied to the power-ground plane analysis which needs a lot of the repeating computation.

발전소 주변압기 운전중 진동 기준치 설정에 관한 연구

  • Lee, W.R.;Lee, J.S.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.587-592
    • /
    • 2005
  • Main transformer's integrity assessment in nuclear power plant is estimated by the electrical test of electrical core and wire and the chemical analysis of insulating oil. Mechanical test or analysis has not been so far. So this study makes it with the vibration velocity rating. The vibration velocity rating in main transformer which is based on the real data of vibration velocity measurement under operating and other machinery vibration code such as ISO code is renewed.

  • PDF

Structural Analysis and Measuring Locations of Upper Guide Structure Assembly in APR1400 (APR1400 상부안내구조물집합체 구조해석 및 측정위치 선정)

  • Ko, Do-Young;Kim, Kyu-Hyung;Kim, Sung-Hwan
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.1
    • /
    • pp.49-55
    • /
    • 2013
  • A reactor vessel internals comprehensive vibration assessment program(RVI CVAP) of an advanced power reactor 1400(APR1400) is being performed as a non-prototype category-2 type of reactor based on the US nuclear regulatory commission regulatory guide(NRC RG) 1.20. The aim of this paper is to present the results of structural response analysis and measuring locations of a upper guide structure(UGS) assembly of the APR1400 reactor. The analysis results of the UGS assembly show that the specified integrity levels meet the design acceptance criteria. Also, the measuring locations are determined by the analysis results of the UGS assembly and selection criteria of previous study. These analysis results and measuring locations will be used as a guide to design a measurement system for the APR1400 RVI CVAP.

Effects of the Training Transfer Management on the Workers in Nuclear Power Plants

  • Kim, Seonsu;Luo, Meiling;Lee, Yong-Hee
    • Journal of the Ergonomics Society of Korea
    • /
    • v.33 no.1
    • /
    • pp.49-58
    • /
    • 2014
  • Objective: The aim of this study is to enhance the efficiency of education and training through application and management of 'Transfer of Training' in nuclear power plants. Background: Despite the sophistication and standardization of job-related skills and techniques of workers, accidents/incidents keep taking place due to human errors and unsafe actions and behaviors, which translates into the necessity to review and examine the effectiveness and influence of education and training on the workers of nuclear power plants. Method/Results: This study drew the factors of 'Transfer of Training' through a review on the preceding studies and document research. In addition, through expert examination, this study explored the expected effects and possibility of application when managing the influencing factors of 'Transfer of Training' in nuclear power plants. And lastly, management priority order for nuclear power plants was drawn through an AHP analysis. Conclusion: Among the 'Transfer of Training' factors, the training design factor was the most important. In addition, the design of the training and transfer and goal setting showed a high degree of importance among the influencing factors. Application: The management of 'Transfer of Training' in nuclear power plants enhances the capability of workers and improves the operational integrity of nuclear power plants.

Factors Influencing Compliance of Patient Role Behavior in Elderly Patients Receiving Hemodialysis (혈액투석을 받는 노인 환자의 환자역할행위이행에 영향을 미치는 요인)

  • Heo, Young-Kyu;Lee, Hyun-Ju
    • Journal of muscle and joint health
    • /
    • v.30 no.3
    • /
    • pp.157-167
    • /
    • 2023
  • Purpose: The purpose of this study was to measure the relationship among activities of daily living, ego integrity, social support and the compliance of patient-role behavior in elderly patients receiving hemodialysis, including the effect of these variables on the compliance of patient-role behavior. Methods: A descriptive survey was conducted with 150 elderly patients over 65 years of age who were also receiving hemodialysis. Data was collected from September 28 to November 13, 2021 and analyzed using t-test, one-way ANOVA, Pearson's correlation coefficients, and multiple regression analysis with SPSS/WIN 26.0. Results: The results show that patient compliance had significant correlations with ego integrity (r=.63, p<.001) and social support (r=.28, p=.001). The other factors influencing patient compliance were the sub-domains of ego integrity, such as the acceptance of the past and the presence (β=.46, p<.001) and attitudes toward life (β=.26 p<.001), with an explanatory power of approximately 35.0% (F=17.21, p<.001). Conclusion: This study confirms that the ego integrity of elderly patients receiving hemodialysis has an effect on the compliance of patient role behavior. Nursing intervention programs that improve the ego integrity of elderly hemodialysis patients could help improve the compliance of patient-role behavior, which is an important factor in the disease management process.

Finite Element Analysis for Wall Thinned Steam Generator Tubes (감육된 증기발생기 전열관의 유한요소 해석)

  • Seong, K.Y.;Ahn, S.H.;Nam, K.W.
    • Journal of Power System Engineering
    • /
    • v.10 no.3
    • /
    • pp.38-44
    • /
    • 2006
  • Failure assessment of steam generator tube are very important for the integrity of energy plants. In pipes of energy plants, sometimes, the local wall thinning may result from severe erosion-corrosion damage. Recently, the effects of local wall thinning on fracture strength and fracture behavior of piping system have been well studied. In this paper, the elasto-plastic analysis is performed by FE code ANSIS on steam generator tube with wall thinning. We evaluated the failure mode, fracture strength and fracture behavior from FE analysis. It was possible to predict the crack initiation point by estimating true fracture ductility under multi-axial stress conditions at the center of the thinned area.

  • PDF

Development of Reliability Analysis Program for Air Operated Valve (공기구동밸브 신뢰도 분석 모듈 개발)

  • 허태영;양상민;김봉호;송동섭;김찬용;이우준
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1080-1082
    • /
    • 2003
  • To develop a reliability analysis program applied to the diagnosis for air operated valve's integrity. we collected, analyzed AOV failure data from foreign and domestic nuclear power plants, and classified whole subjects of this program into several groups according to type and size. We established a theoretical basis using Lognormal Distribution and Bayesian Theory to develop analysis methodology. The result of this program was applied to the calculation of operational unavailability of AOV, and the effect of AOV's failure. Also this program can be applied to the development of diagnostic technique considering AOV environment (temperature, pressure), and setting-up maintenance cycle.

  • PDF

Studies on the heat performance and stability for multi spray type desuperheater of the power plant (발전소용 다중 스프레이형 과열저감기의 열성능 및 안정성에 관한 연구)

  • Cho, Nam-Cheol;Lee, Deok-Gu;Lee, Chae-Moon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.185-190
    • /
    • 2011
  • The important use of the desuperheater(multi spray type) changes the superheated steam into the saturated steam. It is more efficient and suitable for using the process. Also, it is more convenient and stable regarding the process temperature control. In this study, transient and quasi-static analysis were done for the evaluation of structural integrity of the multi spray type desuperheater of the power plant. Computational analysis was used to calculate the thermal stress, and the vibration test was done to evaluate the structural stability. This paper is verified by analysis that water spray nozzle(${\phi}=28mm$) shows the best ability. The results show that structural stability of the desuperheater under the real operating condition was proven.

  • PDF