• Title/Summary/Keyword: Power graph

Search Result 240, Processing Time 0.024 seconds

Power Tracing Method for Transmission Usage Allocation Considering Reactive Power

  • Han Choong-Kyo;Park Jong-Keun;Jung Hae-Sung
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권1호
    • /
    • pp.79-84
    • /
    • 2005
  • In many countries, the electric power industry is undergoing significant changes known as deregulation and restructuring. These alterations introduce competition in generation and retail and require open access to the transmission network. The competition of the electric power industry causes many issues to surface. Among them, unbundling of the transmission service is probably the most complicated as it is a single and integrated sector and the transmission revenue requirement must be allocated to market participants in a fair way. In these situations, it is valuable to research the methodologies to allocate transmission usage. The power tracing method offers useful information such as which generators supply a particular load or how much each generator (load) uses a particular transmission line. With this information, we can allocate required transmission revenue to market participants. Recently, several algorithms were proposed for tracing power flow but there is no dominant power tracing method. This paper proposes a power tracing method based on graph theory and complex-current distribution. For practicability, the proposed method for transmission usage allocation is applied to IEEE 30 buses and compared with the method proposed by Felix F.Wu.

Vertex Coloring based Slot Reuse Scheduling for Power Line Communications

  • Yoon, Sung-Guk
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권5호
    • /
    • pp.2135-2141
    • /
    • 2015
  • Power line communication (PLC) is one of the major communication technologies in smart grid since it combines good communication capability with easy and simple deployment. As a power network can be modeled as a graph, we propose a vertex coloring based slot reuse scheduling in the time division multiple access (TDMA) period for PLCs. Our objective is to minimize the number of assigned time slots, while satisfying the quality of service (QoS) requirement of each station. Since the scheduling problem is NP-hard, we propose an efficient heuristic scheduling, which consists of repeated vertex coloring and slot reuse improvement algorithms. The simulation results confirm that the proposed algorithm significantly reduces the total number of time slots.

Power-flow에 독립적인 파워트레인 모델링 (Power-flow Independent Modeling of Vehicle Powertrain)

  • 최기영;이승종
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.267-270
    • /
    • 2001
  • A lot of efforts have been made to analyze the performance of the vehicle equipped with automatic transmission through simulation. It might be necessary to understand the different types of transmissions, i.e., different power flows, for different models. If there is a module that can be applied to different types of automatic transmission, it could be helpful to transmission-related engineers. This study has started up from this idea. The common bond graph has been obtained from several types of the automatic transmission. The overall generalized equations and kinematic constraint equations have been derived using virtual power sources on common bond graph. They are used to derive state equations and constraints. These equations have been applied as an application to the vehicle equipped with two simple planetary gear set type of Ravigneaux gear type automatic transmission. The state equation, kinematic constraints, and dynamic constraints have been derived in every gear and shift operation using overall generalized equations and kinematic constraint equations. Simulations for constraint speed running, standing-start running, rolling-start running, and LA-4 mode have been conducted to analyze the performance of the vehicle powertrain using GVPS(Generalized Vehicle Powertrain Simulation) program wit pull down menus.

  • PDF

PMU를 이용한 변전소 상태 해석에 관한 연구 (A Study on State Analysis of Substation Using PMU)

  • 김태희;이경민;박철원;전동훈;권대윤;최용성
    • 한국전기전자재료학회논문지
    • /
    • 제37권3호
    • /
    • pp.304-308
    • /
    • 2024
  • In this paper, in order to analyze the PMU data of the accident section, we collected the raw data of a total of 35 PMU installed at the Yeonggwang substation and tried to find a way to analyze the data, and analyzed the data using Excel format and formula. As a result, the three-phase voltage and current data of the PMU were calculated using formulas in Excel and interpreted as effective and reactive power, and it was possible to check the effective and reactive power of the accident section through the graph to see why it was different from before the accident. As a result, it was confirmed that each power was greatly reduced in the graph of the effective and reactive power of the accident section, and it was confirmed that the loss occurred as the power of the accident section was greatly reduced.

THE AUTOMORPHISM GROUP OF COMMUTING GRAPH OF A FINITE GROUP

  • Mirzargar, Mahsa;Pach, Peter P.;Ashrafi, A.R.
    • 대한수학회보
    • /
    • 제51권4호
    • /
    • pp.1145-1153
    • /
    • 2014
  • Let G be a finite group and X be a union of conjugacy classes of G. Define C(G,X) to be the graph with vertex set X and $x,y{\in}X$ ($x{\neq}y$) joined by an edge whenever they commute. In the case that X = G, this graph is named commuting graph of G, denoted by ${\Delta}(G)$. The aim of this paper is to study the automorphism group of the commuting graph. It is proved that Aut(${\Delta}(G)$) is abelian if and only if ${\mid}G{\mid}{\leq}2$; ${\mid}Aut({\Delta}(G)){\mid}$ is of prime power if and only if ${\mid}G{\mid}{\leq}2$, and ${\mid}Aut({\Delta}(G)){\mid}$ is square-free if and only if ${\mid}G{\mid}{\leq}3$. Some new graphs that are useful in studying the automorphism group of ${\Delta}(G)$ are presented and their main properties are investigated.

균형된 실험계획법에서 그래프를 활용한 실험의 크기의 효율적인 결정 (Efficient determination of the size of experiments by using graphs in balanced design of experiments)

  • 임용빈;윤소라;정종희
    • 품질경영학회지
    • /
    • 제46권3호
    • /
    • pp.651-658
    • /
    • 2018
  • Purpose: The algorithm described in Lim(1998) is available to determine the sample size directly given specified significance level, power and signal-to-noise ratio. We research on the efficient determination of the sample size by visual methods. Methods: We propose three graphs for investigating the mutual relationship between the sample size r, power $1-{\beta}$ and the detectable signal-to-noise ratio ${\Delta}$. First graph shows the relationship between ${\Delta}$ and $1-{\beta}$ for the given r and it can be checked whether the power is sufficient enough. Second graph shows the relationship between r and ${\Delta}$ for the given power $1-{\beta}$. Third graph shows the relationship between r and $1-{\beta}$ for the given ${\Delta}$. It can be checked that which effects are sensitive to the efficient sample size by investigating those graphs. Results: In factorial design, randomized block design and the split plot design how to determine the sample size directly given specified significance level, power and signal-to-noise ratio is programmed by using R. A experiment to study the split plot design in Hicks(1982) is used as an example. We compare the sample sizes calculated by randomized block design with those by split plot design. By using graphs, we can check the possibility of reducing the sample size efficiently. Conclusion: The proposed visual methods can help an engineer to make a proper plan to reduce the sample size.

화력 발전소의 기동 시퀀스 진행 모니터링을 위한 자료구조 개발 (Development of a Data Structure for Effective Monitoring of Power Plant Start-up Sequences)

  • 이승철;한승우;김승진
    • 조명전기설비학회논문지
    • /
    • 제23권12호
    • /
    • pp.224-232
    • /
    • 2009
  • 화력발전소를 기동하기 위해서는 수많은 기기조작들이 수동 및 자동으로 또한 순차적 및 병렬로 정확하게 진행되어야 한다. 따라서 발전소의 기동 중 긴박하게 이루어지는 수많은 기기 조작들이 모두 제대로 진행되고 있는지의 여부를 실시간으로 감시하는 일은 매우 복잡하고 긴장을 요하는 임무(task)이다. 본 논문에서는 화력 발전소의 기동시퀀스의 정상 진행 여부를 효과적으로 감시하기 위하여 Event Sequence Monitoring Graph(ESMG)라는 자료구조(Data Structure)를 제안하고 그 구현 기법에 대하여 논하고자 한다. 제안하된 ESMG는 용량 500MW 급의 국내 전형적인 표준형 화력발전소의 주 급수펌프 시스템의 기동 시퀀스의 진행 감시에 적용하기 위한 예를 들었으며 향후 유용하게 활용될 수 있는 가능성을 보였다.

QoSCM: QoS-aware Coded Multicast Approach for Wireless Networks

  • Mohajer, Amin;Barari, Morteza;Zarrabi, Houman
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제10권12호
    • /
    • pp.5191-5211
    • /
    • 2016
  • It is essential to satisfy class-specific QoS constraints to provide broadband services for new generation networks. The present study proposes a QoS-driven multicast scheme for wireless networks in which the transmission rate and end-to-end delay are assumed to be bounded during a multiple multicast session. A distributed algorithm was used to identify a cost-efficient sub-graph between the source and destination which can satisfy QoS constraints of a multicast session. The model was then modified as to be applied for wireless networks in which satisfying interference constraints is the main challenge. A discrete power control scheme was also applied for the QoS-aware multicast model to accommodate the effect of transmission power level based on link capacity requirements. We also proposed random power allocation (RPA) and gradient power allocation (GPA) algorithms to efficient resource distribution each of which has different time complexity and optimality levels. Experimental results confirm that the proposed power allocation techniques decrease the number of unavailable links between intermediate nodes in the sub-graph and considerably increase the chance of finding an optimal solution.

에너지 효율적인 데이타 기반 센서 네트워크 라우팅 프로토콜 (Energy Efficient Data-centric based Sensor Network Routing Protocol)

  • 박노성;김대영
    • 한국정보과학회논문지:정보통신
    • /
    • 제32권2호
    • /
    • pp.261-277
    • /
    • 2005
  • 센서 네트워크에서는 베이스 노드와 다수의 센서 노드들간의 데이타 중심 (Data-centric) 기반의 통신 모델을 사용한다는 특징을 활용하여, 오버헤드를 최소화 하면서 최저 전력 라우팅 경로를 찾고, 또한 전체 네트워크의 수명을 최대화 시킬 수 있는 PAD (Power Aware Data-centric routing protocol)를 제안한다. PAD는 최저전력 라우팅 경로와는 상관없는 통신 링크를 제거한 최저전력특징그래프(Minimum Energy Property Graph)를 찾은 후, 오버혜드를 최소화 하고 slow convergence와 라우팅 경로의 루프 문제를 해결한 Distributed Data-centric Bellman-Ford Algorithm을 사용하여 라우팅 경로를 결정한다. 특히 PAD가 제안한 최저전력특징그래프를 찾는 알고리듬은 기존의 방식에 비해서 훨씬 빠르며, 간단하여 구현이 용이하면서도 가장 적은 수의 에지를 가지는 그래프를 구한다. 이는 기존의 방식이 사용하던 path-loss 모델만을 이용한 기하학적 계산과 복잡한 알고리듬을 path-loss 모델로부터 독립시켜 전력소모를 예측할 수 있는 어떠한 방법이든지 사용 가능하게 하고 또한 최단거리 알고리듬을 사용한 결과이다. PAD는 모든 과정을 분산된 방식으로 수행하며, 또한 최소의 오버헤드만을 가지므로, 다양한 센서 네트워크 응용에서 사용할 수 있을 것으로 기대한다.

현대 뮤지엄 건축의 시지각적 중심성 분석에 관한 연구 - 가시장분석(Visibility Graph Analysis)을 중심으로 - (A Study on Visual-perceptual Centrality in Contemporary Museum Architecture - Focused on Visibility Graph Analysis -)

  • 박종구
    • 한국실내디자인학회논문집
    • /
    • 제23권2호
    • /
    • pp.166-173
    • /
    • 2014
  • This study analyzed visual-perceptual centrality as a measure to solve the confusion that might occur in visitor's movement in analyzing contemporary museums that have recently expand. Also, this study proposed a new methodology to understand the relationships of the occurrence and convergence of visual-perceptual power. The existing visibility graph analysis mostly ends up in identifying nodes corresponding to the physical environment of museums while the newly proposed visibility graph analysis is a methodology that can analyze the landmark on which the visual-perceptual power occurs and converges, by setting visible space elements as analysis variables, which showed a possibility to draw more reliable results in parallel to the existing analysis, and the results of this analysis are as follows. A public museum located in downtown has a limitation that it cannot but be multi-layered as a way to enlarge for the accommodation of a variety of programs on a limited site. Also, this study found that the problem of visitor orientation occurring in the multi-layer process was solved by a major space which was visual-perceptually void. Also, its types can be summarized into two types: One is setting parameter spaces (ramps, staircases, hallways) linked visual-perceptually to the major space and the other is solving the confusion of the visitor's movement by composing a simple exhibition space. In particular, it is judged that the type solving the confusion of the visitor's movement by composing a simple exhibition space also had a relationship with changes in the characteristics of the exhibited works by period. In addition, it was found that the entrance also appeared in two types: dependent type and independent type in the major space according to the characteristics of the major space.