• Title/Summary/Keyword: Power feedback

Search Result 1,262, Processing Time 0.029 seconds

Analysis and Implementation of Single-Stage AC/DC Converter with Magnetic Energy Feedback Technique for Power Factor Correction (역률개선을 위한 자기에너지 궤환기법의 단일전력단 AC/DC 컨버터의 해석 및 구현)

  • 문건우;오관일;전영수
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.2
    • /
    • pp.148-155
    • /
    • 1998
  • A novel single-switch, single-stage, AC/DC forward converter with transformer magnetic energy feedback technique for power factor correction is proposed. The operational principle and analysis of the proposed converter is presented. The proposed converter gives the good power factor correction, low line current harmonic distortions, and tight output voltage regulation. The prototype shows the IEC 555-2 requirements are met satisfactorily with nearly unity power factor.

Power Loading Algorithm for Orthogonalized Spatial Multiplexing in Wireless Communications

  • Kim, Young-Tae;Park, Seok-Hwan;Lee, In-Kyu
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.5A
    • /
    • pp.331-340
    • /
    • 2009
  • In this paper, we propose a new power loading algorithm for orthogonalized spatial multiplexing(OSM) systems over flat-fading multiple-input multiple-output (MIMO) channels. Compared to SVD-based transmission scheme, the OSM scheme exhibits a good system performance with lower complexity and feedback overhead. To further improve the performance in OSM systems with power loading, we introduce a geometric approach on the Euclidean distance between the constellation points in the effective channel. Using this approach, we show that the optimal power loading parameters in terms of the minimum distance can be obtained. Simulation results demonstrate that our algorithm provides a 5dB gain at a bit error rate (BER) of $10^{-4}$ over that of no power loading case with both QPSK and 16-QAM. Consequently, our power loading algorithm allows us to significantly improve the system performance with one additional feedback value.

An Analysis of a Post-Trip Return-to-Power Steam Line break Events

  • Baek, Seung-Su;Lee, Cheol-Sin;Song, Jin-Ho;Lee, Sang-Yong
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05a
    • /
    • pp.544-549
    • /
    • 1995
  • An analysis for Steam Line Break (SLB) events which result in a return-to-power conditions after reactor trip was performed for a postulated Yonggwang Nuclear Power Plant Unit 3 cycle 8. Analysis methodology for post-trip return-to-power SLB is quite different from that of a no return-to-power SLB and is more complicated. Therefore, it is necessary to develop an methodology to analyze the response of the NSSS parameter and the fuel performance for the post-trip return-to-power SLB events. In this analysis, the cases with and without offsite power were simulated by crediting 3-D reactivity feedback effect due to local heatup around stuck CEA and compared with the cases without 3-D reactivity feedback with respect to fuel performance, departure from nucleate boiling ratio (DNBR) and linear heat generation rate (LHGR).

  • PDF

Digital Pre-Distortion Technique Using Repeated Usage of Feedback Samples (피드백 샘플 반복 활용을 이용한 다지털 전치 왜곡 방안)

  • Lee, Kwang-Pyo;Hong, Soon-Il;Jeong, Eui-Rim
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.673-676
    • /
    • 2015
  • Digital Pre-Distortion (DPD) is a linearization technique for nonlinear power amplifiers (PAs) by implementing inverse function of the PA at baseband digital stage. To obtain proper DPD parameters, a feedback path is required to convert the PA output to a baseband signal, and a memory is also needed to store the feedback signals. DPD parameters are usually found by an adaptive algorithm from the feedback samples. However, for the adaptive algorithm to converge to a reliable solution, long feedback samples are required, which increases convergence time and hardware complexity. In this paper, we propose a DPD technique that requires relatively short feedback samples. From the observation that the convergence time of the adaptive algorithm highly depends on the initial condition, this paper iteratively utilizes the feedback samples while keeping and using the converged DPD parameters at the former iteration as the initial condition at the current iteration. Computer simulation results show that the proposed method performs better than the conventional technique while the former requires much shorter feedback samples than the latter.

  • PDF

A Modified Capacitor Current Feedback Active Damping Approach for Grid Connected Converters with an LCL Filter

  • Wan, Zhiqiang;Xiong, Jian;Lei, Ji;Chen, Chen;Zhang, Kai
    • Journal of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.1286-1294
    • /
    • 2015
  • Capacitor current feedback active damping is extensively used in grid-connected converters with an LCL filter. However, systems tends to become unstable when the digital control delay is taken into account, especially in low switching frequencies. This paper discusses this issue by deriving a discrete model with a digital control delay and by presenting the stable region of an active damping loop from high to low switching frequencies. In order to overcome the disadvantage of capacitor current feedback active damping, this paper proposes a modified approach using grid current and converter current for feedback. This can expand the stable region and provide sufficient active damping whether in high or low switching frequencies. By applying the modified approach, the active damping loop can be simplified from fourth-order into second-order, and the design of the grid current loop can be simplified. The modified approach can work well when the grid impedance varies. Both the active damping performance and the dynamic performance of the current loop are verified by simulations and experimental results.

Numerical Analysis on Feedback Mechanism of Supersonic Impinging Jet using LES (LES를 이용한 초음속 충돌제트의 피드백 메커니즘에 대한 수치해석 연구)

  • Oh, Se-Hong;Choi, Dae Kyung;Kim, Won Tae;Chang, Yoon-Suk;Choi, Choengryul
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.13 no.2
    • /
    • pp.51-59
    • /
    • 2017
  • Steam jets ejected from a rupture zone of high energy pipes may cause damage to adjacent structures. This event could lead to more serious accidents in nuclear power plants. Therefore, to prevent serious accidents, high energy pipes of nuclear power plants are designed according to the ANSI / ANS 58.2 technical standard. However, the US Nuclear Regulatory Commission (USNRC) has recently pointed out non-conservatism in existing high energy pipe fracture evaluation methods, and required the assessment of the unsteady load of the jet caused by a potential feedback mechanism as well as the impact range of steam jet, the jet impact loads and the blast wave effects at the initial breakage stage. The potential feedback mechanism refers to a phenomenon in which a vortex formed by impingement jets amplifies vortex itself and induces jet vibration in a shear layer. In this study, CFD methodology using the LES turbulence model is established and numerical analysis is carried out to evaluate the dynamic behavior of impingement jets and the potential feedback mechanism during jet impingement. Obtained results have been compared with an empirical correlation and experiment.

An Active Auxiliary Quasi-Resonant Commutation Block Snubber-Assisted Three Phase Voltage Source Soft Switching PFC Rectifier using IGBTs

  • Hiraki Eiji;Nakaoka Mutsuo;Sugimoto Shigeyuki;Ogawa Shigeaki
    • Journal of Power Electronics
    • /
    • v.5 no.1
    • /
    • pp.29-35
    • /
    • 2005
  • This paper presents a novel prototype of an active auxiliary quasi-resonant snubber(Auxiliary Quasi-Resonant Commutation Block-Link; ARCB)-assisted three phase voltage source soft switching space voltage vector modulated PFC rectifier, which uses Zero Voltage Soft Switching (ZVS) commutation. The operating principles of this digitally-controlled three phase soft switching PWM-PFC rectifier system with an instantaneous power feedback scheme are illustrated and its steady-state performance is evaluated using computer-aided simulation analysis.

Intergrated circuit design of power-stabilizing circuitry for optical transmitter (광송신기용 광파워 안정화 회로의 집적회로 설계)

  • 이성철;박기현;정행근
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.3
    • /
    • pp.47-55
    • /
    • 1996
  • An optical transmitter, which is a key component of the optical transmission system, converts the electrical signal to optical signal and consists of a high-speed current-pulse driver for laser diode and low-speed feedback loops that stabilize optical power against aging, power supply voltage fluctuations, and ambient temperature changes. In this paper, the power-stabilizing part, which forms the bulk of the optical transmitter circuitry was designed in integrted circuits. Operational amplifiers and reference voltage generation circuits, which were identified as key building blocks for the power-stabilizing feedback loops, were designed and were subsequently verified through HSPICE simulations. The designed operational amplifier consists of a two-stage folded cascode amplifier and class AB output stage, whereas the reference voltage is obtained by bandgap reference circuits. Finally the power-stabilizing circuitry was laid out based on 3\mu$m CMOS design rules for fabrication.

  • PDF

Controller Design for Static Reactive Power Generator in Transmission System

  • Han, B.M.;Soh, Y.C.;Kim, H.W.
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.398-403
    • /
    • 1998
  • This paper describes a controller design for the stator reactive power generator in the transmission system. The controller of static reactive power generator was designed using a mathematical model and non-linear state feedback. The performance of controller was verified using computer simulation with EMTP code and experimental work with scaled-model. The dynamic interaction with a simple power system was also analyzed using both the simulation model and hardware scaled-model. Both simulation and experimental results prove that the controller using PI block and non-linear state feedback offers better performance than the controller using PI block only.

  • PDF

Cooperative Power Control Scheme for a Spectrum Sharing System

  • Ban, Tae-Won;Jung, Bang-Chul
    • Journal of information and communication convergence engineering
    • /
    • v.9 no.6
    • /
    • pp.641-646
    • /
    • 2011
  • In this paper, we investigate a power control problem which is very critical in underlay-based spectrum sharing systems. Although an underlay-based spectrum sharing system is more efficient compared to an overlay-based spectrum sharing system in terms of spectral utilization, some practical problems obstruct its commercialization. One of them is a real-time-based power adaptation of secondary transmitters. In the underlay-based spectrum sharing system, it is essential to adapt secondary user's transmit power to interference channel states to secure primary users' communication. Thus, we propose a practical power control scheme for secondary transmitters. The feedback overhead of our proposed scheme is insignificant because it requires one-bit signaling, while the optimal power control scheme requires the perfect information of channel states. In addition, the proposed scheme is robust to feedback delay. We compare the performance of the optimal and proposed schemes in terms of primary user's outage probability and secondary user's throughput. Our simulation results show that the proposed scheme is almost optimal in terms of both primary user's outage probability and secondary user's throughput when the secondary user's transmit power is low. As the secondary user's transmit power increases, the primary user's outage probability of the proposed scheme is degraded compared with the optimal scheme while the secondary user's throughput still approaches that of the optimal scheme. If the feedback delay is considered, however, the proposed scheme approaches the optimal scheme in terms of both the primary user's outage probability and secondary user's throughput regardless of the secondary user's transmit power.