고압유도전동기의 역률개선을 위한 콘덴서 위치 선정 방안 (The Selection of the Condenser Positions for the Improvement Power Factor of the High Voltage Induction Motors)

  • 이은춘;전일방;김창범;최영규;신강욱;홍성택;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1068-1070
    • /
    • 2005
  • This study sorted high voltage motors by the voltage and the capacity and analyzed the property of motor-start. So we found out some problems of the starting circuit from several sites, and made the answers of the problems. If these results of our study are utilized in new WTPs, the safety of the starting circuit will be improved and the life of electric power system will be longer. We recommend this study as a reference when our company founds the standard of electric facility design.

  • PDF

IoT/에지 컴퓨팅에서 저전력 메모리 아키텍처의 개선 연구 (A Study on Improvement of Low-power Memory Architecture in IoT/edge Computing)

  • 조두산
    • 한국산업융합학회 논문집
    • /
    • 제24권1호
    • /
    • pp.69-77
    • /
    • 2021
  • The widely used low-cost design methodology for IoT devices is very popular. In such a networked device, memory is composed of flash memory, SRAM, DRAM, etc., and because it processes a large amount of data, memory design is an important factor for system performance. Therefore, each device selects optimized design factors such as function, performance and cost according to market demand. The design of a memory architecture available for low-cost IoT devices is very limited with the configuration of SRAM, flash memory, and DRAM. In order to process as much data as possible in the same space, an architecture that supports parallel processing units is usually provided. Such parallel architecture is a design method that provides high performance at low cost. However, it needs precise software techniques for instruction and data mapping on the parallel architecture. This paper proposes an instruction/data mapping method to support optimized parallel processing performance. The proposed method optimizes system performance by actively using hardware and software parallelism.

전산해석을 통한 PEMFC 평행 유로에서 Baffle에 의한 출력특성 분석 (Study on Power Characteristics in the PEMFC Parallel Channel with Baffles through Numerical Analysis)

  • 권오정;오창묵;신희선;오병수
    • 전기화학회지
    • /
    • 제17권3호
    • /
    • pp.193-200
    • /
    • 2014
  • 고분자 분리막 연료전지의 성능향상을 위해 분리판 유로설계연구는 필요하다. PEMFC의 성능향상에 대한, 강제대류를 이용한 interdigitated 유로가 최근에 많이 연구되고 있다. 이 논문에서는 interdigitated 유로를 배플들이 있는 평행류 채널에 비슷하게 적용하였다. 상용 multiphysics program인 COMSOL을 이용하여 완전차단배플인 FBB가 있는 평행류 채널에 관해 전산해석을 수행하였고 3가지 변인들(배플 위치, 유체 방향, 유체 속도)이 사용 되었다. 각각 변인들의 출력은 최대출력의 80%를 고려한 0.5V에서의 결과이다. 최종적으로, 실험설계법 중 완전요인실험법을 바탕으로 여러 수준을 갖는 각 실험인자로부터 결론을 도출하였다. 실험인자들의 주효과와 상호작용 분석은 출력을 향상시키는데 가장 영향을 주는 인자를 찾는데 유용하였다.

미션 프로파일을 고려한 단상 5-레벨 태양광 NPC 인버터의 전력 반도체 소자 수명 분석 (Lifetime Evaluation of Power Devices of Single-Phase 5-Level NPC Inverters Considering Mission Profile of PV Systems)

  • 류태림;최의민
    • 전력전자학회논문지
    • /
    • 제27권3호
    • /
    • pp.221-227
    • /
    • 2022
  • The reliability improvement of PV systems is an important factor in reducing the cost of PV energy because it is closely related to the annual energy production as well as the maintenance cost of PV systems. The reliability of PV inverters plays a key role in the reliability of PV systems because it is regarded as one of the most reliable critical parts of PV systems. The lifetime evaluation of PV inverters considering the mission profile in the design phase plays an important role in reliability design to ensure the required lifetime of PV inverters. In this paper, the lifetime of representative single-phase T-type and I-type NPC inverters are comparatively evaluated by considering the mission profile of a PV system recorded at Iza, Spain. Furthermore, the effect of the pulse width modulation methods on the lifetime is also discussed. The lifetime evaluation of PV inverters is performed at the component-level first and then the system level by considering all power devices.

심벌형 압전 에너지 하베스터 에너지 수율 향상 연구 (Research on the Efficiency Improvement of the Cymbal-type Piezoelectric Energy Harvester)

  • 나영민;박종규
    • 한국기계가공학회지
    • /
    • 제16권1호
    • /
    • pp.70-76
    • /
    • 2017
  • The pollution problem of fossil energy sources has caused the development of green energy harvesting systems. Piezoelectric energy harvesting technology has been developed under those external environmental factors. A piezoelectric energy harvester can be defined as a device which transforms mechanical vibration or impact energy into electrical energy. Most researches have focused on bender structures. However, these have a limitation on energy efficiency because of the small effective electromechanical coupling factor, around 10%. Therefore, we should look for a new design for energy harvesting. A cymbal energy harvester can be a good candidate for the high-power energy harvester because it uses a high amplification mechanism using endcaps while keeping a higher electromechanical coupling factor. In this research, we focused on energy efficiency improvements of the cymbal energy harvester by changing the polarization direction, because the electromechanical coupling factor of the k33 mode and the k15 mode is larger than that of the k31 mode. Theoretically, we checked the cymbal harvester with radial polarization and it could obtain 6 times larger energy than that with the k31 direction polarization. Furthermore, we verified the theoretical expectation using the finite element method program. Consequently, we could expect a more efficient cymbal harvester with the radial polarization by comparing two polarization directions.

Is Health Locus of Control a Modifying Factor in the Health Belief Model for Prediction of Breast Self-Examination?

  • Tahmasebi, Rahim;Noroozi, Azita
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권4호
    • /
    • pp.2229-2233
    • /
    • 2016
  • Background: Breast cancer is one of the most common cancers among women in the world. Early detection is necessary to improve outcomes and decrease related costs. The aim of this study was to assess the predictive power of health locus of control as a modifying factor in the Health Belief Model (HBM) for prediction of breast self-examination. Materials and Methods: In this cross- sectional study, 400 women selected through the convenience sampling from health centers. Data were collected using part of the Champion's HBM scale (CHBMS), the Health Locus of Control Scale and a self administered questionnaire. For data analysis by SPSS the independent T test, Chi square test, logistic and linear regression modes were appliedl. Results: The results showed that 10.9% of the participants reported performing BSE regularly. Health locus of control did not act as a predictor of BSE as a modifying factor. In this study, perceived self-efficacy was the strongest predictor of BSE performance (Exp (B) =1.863) with direct effect, while awareness had direct and indirect influence. Conclusions: For increasing BSE, improvement of self-efficacy especially in young women and increasing knowledge about cancer is necessary.

Space Syntax를 이용한 교통수요예측의 중력모형 저항함수의 개선방안 (A Study on Improvement of Gravity model Decay Function of Transporting Demand Forecasting Considering Space Syntax)

  • 장진영
    • 한국산학기술학회논문지
    • /
    • 제20권3호
    • /
    • pp.617-631
    • /
    • 2019
  • 본 4단계 교통수요예측모형의 통행분포단계에서 중력모형이 가장 일반적으로 활용하고 있다. 본 연구는 중력모형변수(통행시간, 통행비용 등)의 가변적인 한계를 보완하기 위해 접근성 속성을 단일 마찰인자로서 표현할 수 있는 보다 현실적이고 장래 활용이 용이한 신규 마찰인자를 개발하는데 그 목적이 있다. 이에 신규 마찰인자 도출을 위해 도시공간구조의 특성을 정량화할 수 있는 공간구문론(space syntax)을 활용하여 Link 단위 통합도를 도출 후 통행시간, 통행거리 관계를 이용해 일종의 대리변수로서의 신규 마찰인자를 도출하였다. 대수전환을 통한 마찰인자별 정산결과, 기존 마찰인자(최단거리, 통행시간) 대비 유사하거나 더 높은 수준을 보이는 것으로 분석되었다. 다양한, 검증지표를 활용하여 기존 마찰인자와의 비교시, 전체적으로는 기존 마찰인자와 유사하지만, 단거리 구간 및 장거리 구간에서 설명력이 뛰어난 것으로 분석되었다. 따라서, 기존 최단거리의 한계에서 벗어나 접근성을 보완할 수 있는 통합도 지표를 이용하여 신규마찰인자 도출 및 적용이 가능하고, 장래 활용성에서 좀 더 장점을 갖는 것으로 판단된다.

Performance Improvement in Single-Phase Electric Spring Control

  • Wang, Qingsong;Zuo, Wujian;Cheng, Ming;Deng, Fujin;Buja, Giuseppe
    • Journal of Power Electronics
    • /
    • 제19권3호
    • /
    • pp.784-793
    • /
    • 2019
  • Two objectives can be pursued simultaneously with the ${\delta}$ control of a single-phase electric spring (ES). These objectives are the stabilization of the voltage across the critical load (CL) of a power system, and the achievement of a specific functionality similar to the pure compensation of reactive power or the correction of the power factor. However, existing control systems implementing the ${\delta}$ control do not cope with non-ideal operating conditions, such as line voltage distortions, and exhibit a somewhat sluggish regulation of the CL voltage. In an effort to improve both the steady-state and transient performances of an ES power system, this paper proposes implementing the ${\delta}$ control by means of a control system built up on the repetitive control and assisted by state feedback with pole assignment. This paper starts by analyzing the dynamics of an ES power system in terms of its poles and zeros. After that, a reduced second-order model of the dynamics is formulated to avoid a notch filter in the pole assignment. A repetitive control for an ES power system is then designed to meet the two above mentioned objectives. Experimental tests carried out on a laboratory setup demonstrate the effectiveness of the proposed control system in significantly improving the ES power system performance, while reaching the two objectives. In particular, the tests outline the large mitigation of harmonics in the CL voltage under line voltage distortions and its fast stabilization action.

Analytical Study on Improvement in Load Sharing for Planetary Gear Set using Floating Ring Gear

  • Chung, Woo-Jin;Choi, Kyujeong;Oh, Jooseon;Park, Young-Jun;Lee, Ki-Hun
    • Journal of Biosystems Engineering
    • /
    • 제43권4호
    • /
    • pp.263-272
    • /
    • 2018
  • Purpose: The load on the planet gear of a planetary gear set is uniformly distributed. However, manufacturing and assembly errors cause uneven load sharing in the planetary gear set. To solve this problem, most studies have suggested applying a floating sun gear to the planetary gear set. However, the effect of the floating ring gear and floating carrier has not been extensively studied. This study aimed to investigate the effect of the floating ring gear. Methods: Two models were developed; one was the fixed ring gear model, and the other was the floating ring gear model. In the fixed ring gear model, the clearance between the ring gear and the housing was $0{\mu}m$, and in the floating ring gear model, the clearance was from $10{\mu}m$ to $100{\mu}m$. The load sharing of the planetary gear set was evaluated by the load sharing factor. Results: Our study showed that with increase in clearance, the load sharing factor of the planetary gear set approached unity. In addition, when the clearance increased above a certain level by which a fully floating ring gear was achieved, the load sharing factor was not affected by the clearance. Conclusions: This indicates that the fully floating ring gear increased the power density of the planetary gearbox by uniformly dividing the load of the planetary gear set. For this reason, the size of the gearbox could be decreased by using a fully floating ring gear.

인버터식 X선장치의 관전압 맥동율 개선에 관한 연구 (A Study on the Improvement of ripple factor tube voltage waveforms in inverter type X-ray generator)

  • 이성길;임홍우;조금배;정수복;백형래
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.234-238
    • /
    • 1999
  • In order to radiate X-ray, the low ripple stabilized high voltage DC over the range of 40KV to 150KV is directly inflicted to X-ray tube. The energy characteristics of the radiated X-ray depend on the pulsating waveforms of the DC voltage supplied X-ray tube. In general, the low ripple voltage waveforms with fast rising times are required to increase with the dosage per unit time lest the exposure time should be longer in orde that the motion artifacts of an object may be eliminated in actual. The conventional types of X-ray generators were bulky in physical size and heavy in weight, and the control accuracies of the output voltages were not always satisfactory. The high frequency switching inverter and converter technology on power conversion and control systems have been greatly closed up introducing new power semiconductor devices. To decreasing the volume and the weight of high voltage transformer, and to stabilize ripple, a high frequency PWM inverter is connected between DC source and high voltage transformer. This paper describes the output characteristics according to stabilize ripple of X-ray tube voltage and compared the reproducibility, direcibility and doesage.