• Title/Summary/Keyword: Power factor improvement

Search Result 384, Processing Time 0.031 seconds

Improvement of Power Transfer Efficiency Using Negative Impedance Converter for Wireless Power Transfer System with Magnetic Resonant Coupling (부성 임피던스 변환기를 적용한 자기공명 방식 무선전력전송 시스템의 효율 개선)

  • Yoon, Se-Hwa;Kim, Tae-Hyung;Park, Jin-Kwan;Kim, Seong-Tae;Yun, Gi-Ho;Yook, Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.12
    • /
    • pp.933-940
    • /
    • 2017
  • A wireless power transfer system with a negative impedance converter(NIC) was designed and tested. The system was investigated to identify the effects of ferrites and conductors. To improve the power transfer efficiency(PTE), the Q-factor of the transmitter was enhanced by the negative resistance generated by the NIC. The NIC was composed of an Op-Amp and resistors. The negative resistance was obtained with respect to a resistor connected in a feedback loop. The dimension of the Tx coil was $250mm{\times}250mm{\times}0.8mm$. The impedance and Q-factor were $31+j1874{\Omega}$ and 60, respectively. The negative resistance was selected to be $30{\Omega}$, and the Q-factor was increased to 900 by reduction of the transmitter resistance, which was about 15 times higher than that of a conventional transmitter. The measured PTE was greatly improved in comparison to that of a conventional system. These results demonstrate that the PTE is enhanced by using the NIC.

A Study for Monitoring & Prognostic Technology of Nuclear Power Plant Critical Equipments (원자력발전소 주요기기에 대한 감시 및 예측진단 기술 적용성 고찰)

  • Jo, Sung-Han;Lee, Jae-Ki;Kim, Hyoung-Gwan
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.11
    • /
    • pp.1090-1094
    • /
    • 2011
  • The major goal of nuclear power industries during past 10 years has been increasing reliability and utility capacity factor. But as capacity factors crept upward, it became harder and harder to attain next percentage of improvement. Therefore, other innovative technologies and method are required. The monitoring, diagnostic and prognostic technologies have been applied to the fossil power plants and contributed a lot on improving their reliability and performance. However nuclear industries are still reluctant to apply the technology by several reasons. In this paper, current preventive maintenance status of nuclear power plants and industrial practice of monitoring, diagnostic and prognostic technologies are investigated. In addition, the restriction in the implementation of the technologies to the nuclear power plants are defined. Finally, we suggest appropriate methods of implementing the technology to nuclear industries for improving current reliability and performance.

Reduced Rating T-Connected Autotransformer Based Thirty-Pulse AC-DC Converter for Vector Controlled Induction Motor Drives

  • Singh Bhim;Bhuvaneswari G.;Garg Vipin
    • Journal of Power Electronics
    • /
    • v.6 no.3
    • /
    • pp.214-225
    • /
    • 2006
  • The design and performance analysis of a reduced rating autotransformer based thirty-pulse AC-DC converter is carried out for feeding a vector controlled induction motor drive (VCIMD). The configuration of the proposed autotransformer consists of only two single phase transformers, with their windings connected in a T-shape, resulting in simplicity in design, manufacturing and in a reduction in magnetics rating. The design procedure of the autotransformer along with the newly designed interphase transformer is presented. The proposed configuration has flexibility in varying the transformer output voltage ratios as required. The design of the autotransformer can be modified for retrofit applications, where presently a 6-pulse diode bridge rectifier is used. The proposed thirty-pulse AC-DC converter is capable of suppressing less than $29^{th}$ harmonics in the supply current. The power factor is also improved to near unity in the wide operating range of the drive. A comparison of different power quality indices at AC mains and DC bus is demonstrated in a conventional 6-pulse AC-DC converter and the proposed AC-DC converter feeding a VCIMD. A laboratory prototype of the proposed autotransformer based 30-pulse AC-DC converter was developed with test results validating the proposed design and system.

Improvement of LCC-HVDC Input-Output Characteristics using a VSC-MMC Structure

  • Kim, Soo-Yeon;Park, Seong-Mi;Park, Sung-Jun;Kim, Chun-Sung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.4_1
    • /
    • pp.377-385
    • /
    • 2021
  • High voltage direct current(HVDC) systems has been an alternative method of a power transmission to replace high voltage alternate current(HVAC), which is a traditional AC transmission method. Due to technical limitations, Line commutate converter HVDC(LCC-HVDC) was mainly used. However, result from many structural problems of LCC-HVDC, the voltage source converter HVDC(VSC-HVDC) are studied and applied recently. In this paper, after analyzing the reactive power and output voltage ripple, which are the main problems of LCC-HVDC, the characteristics of each HVDC are summarized. Based on this result, a new LCC-HVDC structure is proposed by combining LCC-HVDC with the MMC structure, which is a representative VSC-HVDC topology. The proposed structure generates lower reactive power than the conventional method, and greatly reduces the 12th harmonic, a major component of output voltage ripple. In addition, it can be easily applied to the already installed LCC-HVDC. When the proposed method is applied, the control of the reactive power compensator becomes unnecessary, and there is an advantage that the cut-off frequency of the output DC filter can be designed smaller. The validity of the proposed LCC-HVDC is verified through simulation and experiments.

Improvement of prediction methods of power increase in regular head waves using calm-water and resistance tests in waves

  • Chun, Ho-Hwan;Lee, Cheol-Min;Lee, Inwon;Choi, Jung-Eun
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.13 no.1
    • /
    • pp.278-291
    • /
    • 2021
  • This paper applies load variation method to predict speed-power-rpm relationship along with propulsive performances in regular head waves, and to derive overload factors (ITTC, 2018). 'Calm-water tests' and 'resistance test in waves' are used. The modified overload factors are proposed taking non-linearity into consideration, and applied to the direct powering, and resistance and thrust identity method. These indirect methods are evaluated through comparing the speed-power-rpm relationships with those obtained from the resistance and self-propulsion tests in calm water and in waves. The objective ship is KVLCC2. The load variation method predicts well the speed-power-rpm relationship and propulsion performances in waves. The direct powering method with modified overload factors also predicts well. The resistance and thrust identity method with modified overload factor predicts with a little difference. The direct powering method with overload factors predicts with a relatively larger difference.

Stability Analysis and Improvement of the Capacitor Current Active Damping of the LCL Filters in Grid-Connected Applications

  • Xu, Jinming;Xie, Shaojun;Zhang, Binfeng
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1565-1577
    • /
    • 2016
  • For grid-connected LCL-filtered inverters, dual-loop current control with an inner-loop active damping (AD) based on capacitor current feedback is generally used for the sake of current quality. However, existing studies on capacitor current feedback AD with a control delay do not reveal the mathematical relation among the dual-loop stability, capacitor current feedback factor, delay time and LCL parameters. The robustness was not investigated through mathematical derivations. Thus, this paper aims to provide a systematic study of dual-loop current control in a digitally-controlled inverter. At first, the stable region of the inner-loop AD is derived. Then, the dual-loop stability and robustness are analyzed by mathematical derivations when the inner-loop AD is stable and unstable. Robust design principles for the inner-loop AD feedback factor and the outer-loop current controller are derived. Most importantly, ensuring the stability of the inner-loop AD is critical for achieving high robustness against a large grid impedance. Then, several improved approaches are proposed and synthesized. The limitations and benefits of all of the approaches are identified to help engineers apply capacitor current feedback AD in practice.

Thermoelectric properties and microstructures of Mg2Si0.6Sn0.4-based thermoelectric materials (Mg2Si0.6Sn0.4 열전재료의 열전특성과 미세조직)

  • Jang, Jeong-In;Ryu, Byeong-Gi;Lee, Ji-Eun;Park, Su-Dong;Lee, Ho-Seong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.53-53
    • /
    • 2018
  • Thermoelectric materials can convert directly waste heat to electricity and vice versa. The improvement of the thermoelectric efficiency strongly depends on the dimensionless figure of merit, $ZT=S^2{\sigma}T/{\kappa}$, where S is the Seebeck coefficient, ${\sigma}$ is the electrical conductivity, T is the absolute temperature, and ${\kappa}$ is the thermal conductivity. The thermal conductivity consists of the electronic contribution (${\kappa}_e$) and phonon contribution (${\kappa}_{ph}$). It is very challenge to increase the power factor, $S^2{\sigma}$ and to reduce the thermal conductivity simultaneously because the power factor and electronic thermal conductivity are coupled. One strategy is to decrease the phonon thermal conductivity. The phonon thermal conductivity can be decreased by controlling the grain size and structural defects such as dislocations and twinning. In order to achieve enhancements in thermoelectric efficiency, microstructures that can form numerous interfaces have been investigated intensively for controlling the transport of charge carriers and heat carrying phonons. In this presentation, we report the heterogeneous microstructure of $Mg_2Si_{0.6}Sn_{0.4}$ thermoelectric materials and investigation of its influence on thermoelectric properties.

  • PDF

Process Development for Enhancement of High Temperature Thermoelectric Properties in a p-Type Skutterudite (P-형 Skutterudite 소재의 고온 열전물성 제어를 위한 공정 개발)

  • Liu, Peng Ju;Nou, Chang Wan;Choi, Soon-Mok
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.6
    • /
    • pp.495-499
    • /
    • 2020
  • Power factor improvement at high temperatures has been a major research topic for the development of skutterudite thermoelectric materials. Here, we attempted to optimize the process parameters for manufacturing skutterudite materials, especially for p-type systems. We focused on the effect of aging time variation to maximize the high-temperature performance of the Ce-filled Fe3CoSb12 skutterudite system. The optimized aging time was concluded to be a key parameter for the formation of single-phase nanostructures in this p-type skutterudite system. The optimized condition was effective in reducing the bipolar effect at high temperature ranges by increasing the carrier concentration in the p-type system. To confirm the conclusions, the electrical conductivity, Seebeck coefficient, and power factor were measured. The results matched well with the microstructure and with those of an XRD analysis performed for the system.

A Study for Efficiency Improvement of Feedforward Power Amplifier by Using Doherty Amplifier (Doherty증폭기를 이용한 Feedforward전력 증폭기의 효율 개선에 관한 연구)

  • Lee Taek-Ho;Jung Sung-Chan;Park Cheon-Seok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.11 s.102
    • /
    • pp.1059-1066
    • /
    • 2005
  • This paper reports an application of Doherty amplifier for efficiency improvement of feedforward power amplifier(FPA). For performance analysis, we measured 15 W average output power using WCDMA 4FA input signal with a center frequency 2.14 GHz. The applied Doherty amplifier presents the characteristics of high efficiency and low linearity in comparison to the class AB amplifier, and it was used as main amplifier of FPA fir efficiency improvement. To analyze the change of characteristic, tow Doherty amplifiers whose linearity and efficiency are different were applied. The applied FPAs are improved about $2\%$ or more performance in efficiency, but decreased in linearity on 15 W average output power. We additionally modified the coupling factor(CF) of the error loop and the error amplifier capacity for linearity improvement. Aa a result, the efficiency improvement and high linearity resulted from the change of CF and error amplifier capacity. However, we think if the linearity of Doherty amplifier were more than 35 dBc, the FPA would improve the performance about $2\%$ or more efficiency and maintain enough linearity.

A 900 MHz VCO Having 7-dB Phase Noise Improvement at 100 kHz Offset

  • Lee, Ja-Yol;Kang, Jin-Young;Oh, Seung-Hyeub
    • Journal of electromagnetic engineering and science
    • /
    • v.4 no.3
    • /
    • pp.107-112
    • /
    • 2004
  • In this paper, the phase noise of 900 MHz VCO is improved using modified strip line square ring resonator. In order to demonstrate the phase noise improvement of the proposed VCO, the same circuit was manufactured using shorted-circuit resonator. In condition of the same bias current, the phase noise of the proposed VCO with modified square ring resonator is suppressed by 7 dB as - 103 dBc/Hz at 100 kHz offset compared to the conventional VCO with short-circuit resonator. From the proposed VCO, we achieved output power of - 4.8 dBm, harmonics suppression of 16 dB, and tuning bandwidth of 100 MHz. The proposed VCO consumed 5 mA at 3 V, and its size is 1.2 cm ${\times}$ 1.0 cm.