• Title/Summary/Keyword: Power facility management

Search Result 253, Processing Time 0.023 seconds

Effective modular assembly line control system

  • Eom, Eu-Gan;Kim, Dong-Shin;Ahn, In-Seok;Park, Jong-Oh;Kim, Young-Tae;Kim, Sung-Kwon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10b
    • /
    • pp.293-297
    • /
    • 1993
  • In this paper, a new design method for Assembly Line Control System(ALCS) is presented. This system consists of five independent modules having their own specific functions such as production management, facility management material management, quality management, and remote control. To implement the ALCS, we propose design of the common data management module(CDMM). This module has the roles of integrating the above five modules and of communicating the common data between them. Using this method, we realize an information management method in the view of CIM. In addition, we standardize the inter-communication of common data between machines having different interface protocols.

  • PDF

A Study on the Application and Verification of Statistical Techniques for Calculating the Life of Electric Power Facilities (전력설비의 수명계산을 위한 통계적 분석기법의 활용 및 검증에 대한 연구)

  • Lee, Onyou;Kim, Kang-Sik;Lee, Hongseok;Cho, Chongeun;Kim, Sang-Bong;Park, Gi-Hun
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.1
    • /
    • pp.9-14
    • /
    • 2022
  • Social infrastructure facilities such as production, transportation, gas and electricity facilities may experience poor performance depending on time, load, temperature, etc. and may require maintenance, repair and management as they are used. In particular, in the case of transformers, the process of managing them for the purpose of preventing them from failing is necessary because a failure can cause enormous social damage. The management of transformers should consider both technical and economic aspects and strategic aspects at the same time. Thus, it applies the Asset Management concept, which is widely used in the financial industry as an advanced method of transformer management techniques worldwide. In this paper, the operation and power outage data were secured for the asset management of the transformer for distribution, and the asset status was analyzed. Analysis of asset status using actual operation and power outage data is essential for assessing the statistical life and failure rate of the facility. Through this paper, the status of transformer assets for arbitrary A group distribution was analyzed, and the end of life and replacement life were calculated.

A Risk Evaluation Model of Power Distribution Line Using Bayesian Rule -Overhead Distribution System- (베이즈 규칙을 활용한 배전선로 위험도 평가모델 -가공배전분야-)

  • Joung, Jong-Man;Park, Yong-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.6
    • /
    • pp.870-875
    • /
    • 2013
  • After introducing diagnosis equipment power failure prevention activities for distribution system have become more active. To do facility diagnosis and maintenance work more efficiently we need to evaluate reliability for the system and should determine the priority line with appropriate criteria. Thus, to calculate risk factor for the power distribution line that are composed of many component facilities its historical failure events for the last 5 years are collected and analysed. The failure statics show that more than 60% of various failures are related to environment factors randomly and about 20% of the failures are refer to the aging. As a strategic evaluation system reflecting these environmental influence is needed, a system on the basis of the probabilistic approach related statical variables in terms of failure rate and failure probability of electrical components is proposed. The figures for the evaluation are derived from the field failure DB. With adopting Bayesian rule we can calculate easily about conditional probability query. The proposed evaluation system is demonstrated with model system and the calculated indices representing the properties of the model line are discussed.

A Study on the new MBT management system with variations of MSW's seasonal emission characteristics (생활폐기물의 계절별 성상변화에 따른 MBT 시스템 관리에 관한 연구)

  • Min, Byong-Hoon;Chung, Chan-Kyo;Kim, Jong-Moon;Min, Dul-le;Lim, Seung-Bin;Lee, Chae-Young;Kim, Hyung-Jin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.18 no.4
    • /
    • pp.54-63
    • /
    • 2010
  • When MBT(Mechanical Biological Treatment) facility is designed, the management system adequate for domestic circumstance in Korea has been insufficient and power plant's load on seasonal variation has not been resolved yet. Thus, this study introduced MBT facility and MSW(Municipal Solid Waste)'s seasonal emission characteristics were investigated in order to establish new MBT management system. and additional thermal buffer-materials's calorific values were also considered to reduce the power plant's load. The results showed that the screening efficiency of MBT facility and the physical characteristics of each waste can be identified, and the calorific value by seasonal variation for MBT facility can be kept constant all the year round by using an additional thermal buffer-materials.

Radiological Environment Investigation of Radioactive Waste Disposal Facility (방사성폐기물 처분시설 주변의 방사선환경조사)

  • Baek, Jeong-Seok;Jeong, Yeui-Young;Ahn, Sang-Bok;Kim, Wan
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.4
    • /
    • pp.387-398
    • /
    • 2008
  • To obtain base-line data in the low- and intermediate-level radioactive waste disposal facility, radiological environment investigation is required at least two years prior to the facility operation near the disposal facility. The investigation has been performed since January 2007 for the Wolsong LILW disposal center. In this paper, investigation procedure and detailed information obtained for six months in 2008 are described. Based on the current results, future investigation planning is also discussed for the radiological environment management of the disposal facility.

  • PDF

Earthquake hazard and risk assessment of a typical Natural Gas Combined Cycle Power Plant (NGCCPP) control building

  • A. Can Zulfikar;Seyhan Okuyan Akcan;Ali Yesilyurt;Murat Eroz;Tolga Cimili
    • Geomechanics and Engineering
    • /
    • v.35 no.6
    • /
    • pp.581-591
    • /
    • 2023
  • North Anatolian Fault Zone is tectonically active with recent earthquakes (Mw7.6 1999-Kocaeli and Mw7.2 1999-Düzce earthquakes) and it passes through Marmara region, which is highly industrialized, densely populated and economically important part of Turkey. Many power plants, located in Marmara region, are exposed to high seismic hazard. In this study, open source OpenQuake software has been used for the probabilistic earthquake hazard analysis of Marmara region and risk assessment for the specified energy facility. The SHARE project seismic zonation model has been used in the analysis with the regional sources, NGA GMPEs and site model logic trees. The earthquake hazard results have been compared with the former and existing earthquake resistant design regulations in Turkey, TSC 2007 and TBSCD 2018. In the scope of the study, the seismic hazard assessment for a typical natural gas combined cycle power plant located in Marmara region has been achieved. The seismic risk assessment has been accomplished for a typical control building located in the power plant using obtained seismic hazard results. The structural and non-structural fragility functions and a consequence model have been used in the seismic risk assessment. Based on the seismic hazard level with a 2% probability of exceedance in 50 years, considered for especially these type of critical structures, the ratios of structural and non-structural loss to the total building cost were obtained as 8.8% and 45.7%, respectively. The results of the study enable the practical seismic risk assessment of the critical facility located on different regions.

A Study on the Development of Industrial Power Management System (수용가 전력관리시스템 개발 연구)

  • Moon, Young-Hwan;Seong, Ki-Chul;Yoon, Sang-Hyun;Kim, Eon-Chung
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.550-552
    • /
    • 1995
  • Real time informations from industrial power system in operation can be used for efficient energy conservation, optimal operation of electrical equipments, and expansion planning of apparatus. Requirements for energy conservation and supplied power quality in customers are increasing significantly because of their effects on the production cost and efficiency. Thus, the development of low cost power management system which can can operate in domestic power system properly is substantially requested. In this research, operation software for real time monitoring and control system in customer power system has been developed to achieve the above purposes. The development of the operating software and related technologies are expected to be applied successfully for reducing electricity cost, enhancing power quality, determining facility expansion planning, operating optimal power system, increasing production efficiency, and reducing maintenance cost.

  • PDF

Research & Development on the Scaffolding for Cylindrical Desulfurizers Facility Maintenance (원통형 탈황설비 정비용 비계 연구개발)

  • Lee, Kwang-Gil;Kim, Woo-Gon;Eum, Seok-Ho;Kang, Cheol-Min;Kang, Jeong-Ki;Oh, Cheol-Seok;Seo, Ju-Sik;Kim, Kyeong-Jae;Park, Jong-In;Jang, Mong-Yong;Kim, Moo-Seong;Kim, Dae-Nyeon;Jung, Soo-Ho
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.3
    • /
    • pp.1-8
    • /
    • 2020
  • The desulfurizers facility is cylindrical shape. To operate properly it needs nozzles cleaned, get rid of lime adhesion and sludge, repair the wear and corrosion of facility regularly. For this purpose, workers shall access the ceiling or vertical wall at high place. Ordinary scaffoldings such as steel pipe scaffolding or system scaffolding have been using so that workers can access them. With these ordinary scaffoldings, openings around cylindrical wall are inevitable which make workers can expose always to the risk of falling. The purpose of this study is to develop customized scaffolding to minimize the openings to prevent workers form falling during maintenance it. It consists of a hexagonal central tower and six trapezoidal outer towers. And the bracing among the towers have connected each other for self-standing and for maintaining the structure of towers. Span decks, the circumference footstools, steps, etc. are laid on each floor. The safety is reviewed by structural analysis and performance test. With this study, openings each floor of this scaffold are removed. The gap between the cylindrical wall and the edge of the work stage is approximately 100 mm. Therefore, we expect that workers can work safely and efficiently.

Artificial Rainfall Test of the Engineered Cover Barriers for Near Surface Disposal of LILW

  • Park, Jin-Beak;Park, Se-Moon;Kim, Chang-Lak
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.306-314
    • /
    • 2003
  • Engineered barrier test facility is specially designed to demonstrate the performance of engineered barrier system for the near-surface disposal facility under the domestic environmental conditions. Comprehensive measurement systems for the water content, temperature, matric potential are installed within each test cell. In this study, short-term monitoring of the behavior of multi-layered cover system is implemented with artificial rainfall system. The periodic measurement data are collected and analyzed by a dedicated database management system, and provide a basis for performance verification of the disposal cover design.

  • PDF

Database Modeling and Environmental Information for a Radioactive Waste Repository Site

  • Park S. M.;Rhee C. G.;Park J. B.;Lee H. J.;Kim Chang Lak
    • Nuclear Engineering and Technology
    • /
    • v.36 no.3
    • /
    • pp.263-275
    • /
    • 2004
  • For the safe management of nuclear facilities, including a radioactive waste repository, data about the facility site and the surrounding environment must be collected and managed systematically. This is particularly true for a radwaste repository, which has to be institutionally controlled for a long period after closure. The objectives of this study are (1) to establish a systematical management plan for information about a radwaste repository site and its environment, and (2) to design a database management program for this information, based on the Relative Database Management System (RDBMS). The spatial data are designed by the geodatabase, which is a new object, based on the RDBMS, to manage spatial information related to the database. To meet this requirement, a new program called 'Site Information and Total Environmental data management System (SITES)' is being developed. The scope that produced from the first step of the present study for development of the SITES is introduced. The database is designed to combine spatial and attribute data, and is designed for the establishment of the Geographic Information System (GIS). The hardware and software systems are designed with consideration given to the total data management of the items within the radioactive environment.