• Title/Summary/Keyword: Power equipment

Search Result 4,021, Processing Time 0.029 seconds

The Design of high Efficiency APLC for the Low Power load (저용량 부하를 위한 고효율 APLC의 설계)

  • 김병진;전희종
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.2
    • /
    • pp.217-221
    • /
    • 2001
  • In this paper, APLC(Active Power Line Conditioner) is designed for low consumed power electrical equipment such as communication electronic equipment, computer sever and etc.. Because APLC which is hunted to the mains controls only the elements of harmonics, the designed APLC is very high efficient. Additionally, controller designed with low cost micro-controller and analog circuit has good merit economically. Simulation and experimental results on a prototype verify the feasibility of the proposed scheme.

  • PDF

Construction of Spread Spectrum Power Line Communication Equipment Using Power Line Synchronization (전원동기를 이용한 스펙트럼 확산 전원선 통신장치의 구성)

  • 이동욱;변건식;김명기
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.15 no.6
    • /
    • pp.475-484
    • /
    • 1990
  • This paper proposes a method for the implementation of a power line communication equipment using power line synchronization in a direct-sequence spread spectrum communication system. In order to implement a network using a power line as a transmission channel we have investigated the utilization of direct-sequence speread spctrum which gives such advantages as robustness against narrow-band interference and noise, and realization of multiple access. In a power line, however, complexity of synchronization makes it difficult to realize a multiple access and cost down and system simplification. The proposed technique of power line synchronization makes it possible to get cost down and system size small, and the realization of multiple communication can be achieved by the addition of address setting circuit.

  • PDF

Improved Side Channel Analysis Using Power Consumption Table (소비 전력 테이블 생성을 통한 부채널 분석의 성능 향상)

  • Ko, Gayeong;Jin, Sunghyun;Kim, Hanbit;Kim, HeeSeok;Hong, Seokhie
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.27 no.4
    • /
    • pp.961-970
    • /
    • 2017
  • The differential power analysis calculates the intermediate value related to sensitive information and substitute into the power model to obtain (hypothesized) power consumption. After analyzing the calculated power consumption and measuring power consumption, the secret information value can be obtained. Hamming weight and hamming distance models are most commonly used power consumption model, and the power consumption model is obtained through the modeling technique. If the power consumption model assumed by the actual equipment differs from the power consumption of the actual equipment, the side channel analysis performance is declined. In this paper, we propose a method that records measured power consumption and exploits as power consumption model. The proposed method uses the power consumption at the time when the information (plain text, cipher text, etc.) available in the encryption process. The proposed method does not need template in advance and uses the power consumption measured by the actual equipment, so it accurately reflects the power consumption model of the equipment.. Simulation and experiments show that by using our proposed method, side channel analysis is improved on the existing power modeling method.

Design and Analysis of Lorentz Force-type Magnetic Bearing Based on High Precision and Low Power Consumption

  • Xu, Guofeng;Cai, Yuanwen;Ren, Yuan;Xin, Chaojun;Fan, Yahong;Hu, Dengliang
    • Journal of Magnetics
    • /
    • v.22 no.2
    • /
    • pp.203-213
    • /
    • 2017
  • Magnetically suspended control & sensitive gyroscope (MSCSG) is a novel type of gyroscope with the integration of attitude control and attitude angular measurement. To improve the precision and reduce the power consumption of Lorentz Force-type Magnetic Bearing (LFMB), the air gap flux density distribution of LFMB has been studied. The uniformity of air gap flux density is defined to qualify the uniform degree of the air gap flux density distribution. Considering the consumption, the average value of flux density is defined as well. Some optimal designs and analyses of LFMB are carried out by finite element simulation. The strength of the permanent magnet is taken into consideration during the machining process. To verify the design and simulation, a high-precision instrument is employed to measure the 3-dimensional magnetic flux density of LFMB. After measurement and calculation, the uniform degree of magnetic flux density distribution reaches 0.978 and the average value of the flux density is 0.482T. Experimental results show that the optimal design is effective and some useful advice can be obtained for further research.

A Study on ground fault at low voltage line and apparatus in urban railway station (도시철도역사의 저압선로 및 기기에서의 지락사고 방지 방안에 관한 검토)

  • Min Kyung-Yun;Kim Jin-Ho;Han Hag-Su
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.699-704
    • /
    • 2005
  • In the station of the railway and the subway various illumination equipment and a general power equipment for a passenger convenience, the signal equipment and the communication equipment which is necessary to the train operation provided. At the all of like this equipment from the electric room which is established in each station by changing from high voltage to low voltage and it supplies from the illumination transformer, the power transformer and the signal transformer. If it supplies to the equipment from the high voltage to the low voltage, it must be established to contact protection device in between the high voltage coil and the low voltage coil. Also it must do the grounding faulting device at the low voltage lines, the earthing devices at apparatus for the protection of an electric shock and an electric fire by the electric relation law. Compared the related regulations between the facilities which require protective functions such as grounding fault or earthing in public utilities like subway stations, and the facilities which do not require line earthing or protective functions such as electricity supplied for signalling the train. Also, will describe a countermeasure for the accident from a grounding fault.

  • PDF

A Study on Performance Evaluation and Security Methods of u-IT Electrical Safety Integrated Management System's Module (u-IT 전기안전통합관리시스템의 모듈별 성능평가와 보안방법 연구)

  • Park, Dae-Woo;Kim, Eung-Sik;Choi, Choung-Moon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.6
    • /
    • pp.1447-1452
    • /
    • 2010
  • Ubiquitous society to build basic infrastructure in the power supply and power equipment safety is important. u-City in order to prevent the disaster of u-IT Power Equipment Performance Module and the security for the safety of the u-City is necessary. In this paper, the power unit of u-IT module, temperature sensor, humidity sensor, equipped with sensors arranged throughout the fire, and home distribution boards, Home Network Wall-Pad, Blocker, MPNP black boxes, arc detection, arc safety equipment, outlet of the modular performance evaluation methods and security methods will be studied. u-IT power devices and sensors to analyze the information conveyed by proactive risk and ensure safety, access control, authentication, security safeguards, such as u-IT integrated management system for electrical safety and strengthen the security, safety and security with a u-City will contribute to the construction and operation.

VERIFICATION OF ELECTROMAGNETIC EFFECTS FROM WIRELESS DEVICES IN OPERATING NUCLEAR POWER PLANTS

  • YE, SONG-HAE;KIM, YOUNG-SIK;LYOU, HO-SUN;KIM, MIN-SUK;LYOU, JOON
    • Nuclear Engineering and Technology
    • /
    • v.47 no.6
    • /
    • pp.729-737
    • /
    • 2015
  • Wireless communication technologies, especially smartphones, have become increasingly common. Wireless technology is widely used in general industry and this trend is also expected to grow with the development of wireless technology. However, wireless technology is not currently applied in any domestic operating nuclear power plants (NPPs) because of the highest priority of the safety policy. Wireless technology is required in operating NPPs, however, in order to improve the emergency responses and work efficiency of the operators and maintenance personnel during its operation. The wired telephone network in domestic NPPs can be simply connected to a wireless local area network to use wireless devices. This design change can improve the ability of the operators and personnel to respond to an emergency situation by using important equipment for a safe shutdown. IEEE 802.11 smartphones (Wi-Fi standard), Internet Protocol (IP) phones, personal digital assistant (PDA) for field work, notebooks used with web cameras, and remote site monitoring tablet PCs for on-site testing may be considered as wireless devices that can be used in domestic operating NPPs. Despite its advantages, wireless technology has only been used during the overhaul period in Korean NPPs due to the electromagnetic influence of sensitive equipment and cyber security problems. This paper presents the electromagnetic verification results from major sensitive equipment after using wireless devices in domestic operating NPPs. It also provides a solution for electromagnetic interference/radio frequency interference (EMI/RFI) from portable and fixed wireless devices with a Wi-Fi communication environment within domestic NPPs.

Repair and Replacement Methodology for Electrical Equipment Used in Nuclear Power Plants (원자력발전소 전기기기의 보수, 교체 방법론)

  • Park, Chulhee;Park, Wan-gyu;Lee, Manbok;Kim, Choon-sam
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.177-179
    • /
    • 2018
  • After Fukushima nuclear accident at 2011, nuclear industrial has been focused on operation and maintenance phase, not design and construction phase. Continued good operating performance of nuclear power plants has been the best critical issue to nuclear utilities. Replacement for complete components as well as parts of components is being procured because nuclear utilities must maintain safety and reliability of operating nuclear power plants. However, many suppliers and manufacturers are giving up a nuclear quality assurance program under reduction in new construction of nuclear power plants. It is able to be increased difficulty in procuring spare parts to support operations and maintenance of nuclear power plants. Over 20% of nuclear power plant equipment in some countries is obsolete. Owing to obsolescence of nuclear safety-related items and/or withdrawing a nuclear quality assurance program of suppliers and manufactures, some replacement item and part might be procured to the item not covered by appendix B to USNRC 10 CFR Part 50. Under various methods of the nuclear repair and replacement methodology, utilities are supposed to establish a typical program for a repair and replacement of an electrical equipment and its parts in conjunction with a nuclear quality assurance. Concerning this typical program, this study suggests the repair and replacement methodology of electrical equipments used in nuclear power plants by procurement of a power supply, based on nuclear regulations, codes, standards, guidelines, specific and general technical information, etc..

  • PDF

A Study on the Optimization of the Design of Power Electric Ground Support Equipment according to the Increase in Power Demand due to the Increase in Satellite Power Demand and the Advancement of Satellite Payload (위성 탑재체 고도화에 따른 위성 전력요구도 증가 및 전력요구도 증가에 따른 전력계 전기지상지원장비 설계 최적화를 위한 고찰)

  • Su-Wan Bang;Hyoung-Ho Ko
    • Journal of Aerospace System Engineering
    • /
    • v.17 no.1
    • /
    • pp.88-96
    • /
    • 2023
  • KOMPSAT (Korean Multi-Purpose Satellite) is a Low-Earth-Orbit (LEO) satellite under development in Korea. Its performance has been steadily improving. At this time, power demand of the payload increased according to performance improvement of the payload. Accordingly, design of the satellite, such as design of the internal power supply device and the configuration of the solar array, was changed. Thus, many considerations are required according to an increase in power when designing power EGSE (Electric Ground Support Equipment) for supplying power to satellites and conduct satellite integration tests. This paper deals with matters to be considered when designing power EGSE according to changes in satellite power requirements according to payloads and increase in power requirements.

Standby Strategies for Energy Saving in Peripheral Equipment of Machine Tools (공작기계 주변장치의 에너지 절감 대기전략)

  • Kim, Taejung;Kim, Taeho;Jee, Sungchul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.5
    • /
    • pp.486-492
    • /
    • 2013
  • Energy cost has been increasing rapidly to comply with environmental regulations worldwide and the manufacturing industry who consumes more than half of the total energy needs to improve their cost competitiveness considering environmental costs. Machine tools are essential elements in manufacturing industry and efforts have been made recently to increase their energy efficiency mainly by German and Japanese machine tool builders. In this paper, trends in energy saving technology are described on the hardware and software sides of peripheral equipment of machine tools. In addition, the power consumption of a machining center is measured and analyzed to develop a software-based standby strategy for energy saving with peripheral equipment of machine tools.