• Title/Summary/Keyword: Power equipment

Search Result 4,021, Processing Time 0.026 seconds

Expected Future Market Volume of HTS Equipment in South Korea

  • Yoon, Jae-Young;Lee, Seung-Ryul;Yang, B.;Lee, Seung-Yeup;Won, Young-Jin
    • Journal of Magnetics
    • /
    • v.16 no.2
    • /
    • pp.129-133
    • /
    • 2011
  • This paper shows the entire future market volume of the HTS power industry, one of main smart grid equipment, in the case of the final market penetration ratio reaching 100% in the domestic market (South Korea). In this paper, the market penetration ratio is determined using the judgment method, with the market penetration S-curve induced using the Delphi method and the Product Life Cycle from 2011 (supposed launching year, not realistic physical year), to 2050 (expected final target year). This paper analyzes the HTS market penetration ratio of each stage, apparent innovation, early adapters, and the early/late majority and laggard stage, using the S-curve, thus calculating the total future market volume of HTS equipment in the positive sense. Finally, this paper estimates the quantitative analysis results for the HTS4-items (cable, FCL, transformer, rotation machine) of each year within the domestic market.

To examine the construction plan of the lightening rod equipment for the J-booster pumping station in and around KEPCO'a high voltage distribution power line (한전 배전선로 주변에 위치한 J가압장의 피뢰설비 구축방안 검토)

  • Hong, Sung-Taek;Lee, Eun-Chun;Shin, Gang-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.293-295
    • /
    • 2003
  • KEPCO's high voltage distribution power line laid under the ground near to the J-booster pumping station that supply water for living. Lightening rod equipment does not installed at the J-booster pumping station because KEPCO's over head ground wire for protection functions as a lightening rod equipment. In this study, it is concerned whether KEPCO's over head ground wire for protect the distribution power line affect to the J-booster pumping station which is installed for reduce the damage from the direct and indirect lightening. If KEPCO's protection area does not affect to the J-pumping station, it is plan to examine the construction method of lightening rod protection angle and lightening rod equipment and to suggest the optimum protection plan using the surrounding structure based on the suitability of protection area.

  • PDF

Quality Assurance system for Nuclear Power Plant Equipment Qualification in Korea (국내 원전기기 성능검증 품질보증체계 구축에 관한 연구)

  • 남지희;이영건;임남진
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.25 no.3
    • /
    • pp.1-8
    • /
    • 2002
  • This paper investigates different QA standards such as KEPIC QAP, KEPIC END 1200, ISO/1EC 17025 etc. and as a result defines QA elements for Nuclear Power Plant equipment qualification(EQ) in Korea. This paper also proposes a practical QA certification system appropriate for an Integrated Organization for EQ which is being planned to be established in Korea. Since the level of the Korean EQ technology is comparatively low, the Korean manufacturers of the Nuclear Power Plant(NPP) equipment have usually used overseas EQ services. The EQ related organizations in Korea are making efforts to construct the integrated EQ system. In connection with this, it is required that the QA elements and QA certification system suitable for EQ in Korea be developed.

Implementation of Status Monitoring System based on RFID in Electric Power Equipment (발전설비장치에서 RFID기반 상태관리시스템 구현)

  • Han, Gun-Hee;Hong, Jin-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.9
    • /
    • pp.2379-2383
    • /
    • 2009
  • In this paper, it is reviewed implementation of information system base on RFID for management of power equipment, and the managed status items are input/out of resource, purchasing and ordering, drawing management, equipment specification, handling of operator, received order, stock control, production results, system management, and so on. the proposed paper is designed and implemented based on RFID status management system to support monitoring services of diagnosis the failure status monitoring.

On-Line Condition Monitoring of Electrical Equipment Using Temperature Sensor (온도센서를 이용한 전력설비의 온라인 상태 감시)

  • Choi, Yong-Sung;Kim, Sun- Jae;Kim, Yeong-Min;Song, Hwao-Kee;Lee, Kyung-Sup
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.202-208
    • /
    • 2008
  • Condition monitoring technologies allow achieving this goal by minimizing downtime through the integrated planning and scheduling of repairs indicated by condition monitoring techniques. Thermal runaways induced by conduction problems deteriorate insulating material and cause disruptive dielectric discharges resulting in arcing faults. Therefore, having the ability to directly measure the temperature of the contacts while in service will provide more information to determine the true condition of the equipment. It allows connective measures to be taken to prevent upcoming failure. Continuous temperature monitoring and event recording provides information on the energized equipment's response to normal and emergency conditions. On-line temperature monitoring helps to coordinate equipment specifications and ratings, determine the real limits of the monitored equipment and optimize facility operations. Using wireless technique eliminates any need for special cables and wires with lower installation costs if compared to other types of online condition monitoring equipment. In addition, wireless temperature monitoring works well under difficult conditions in strategically important locations. Wireless technology for on -line condition monitoring of energized equipment is applicable both as stand alone system and with an interface for power quality monitoring system. The paper presents the results of wireless temperature monitoring: of electrical equipment at a power plant.

Maintenance-Effectiveness Analysis of Photovoltaic Equipment for Detached Houses (주택용 태양광발전설비의 유지관리 효과 분석)

  • Park, Byeong-Hun;Choi, Jong-Won;Kim, Jae-Yeob
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.4
    • /
    • pp.359-365
    • /
    • 2016
  • With the government's support using new and renewable energy, photovoltaic equipment has been rapidly supplied. However, compared to supply rate, maintenance has not supported enough and relevant research has not much conducted. Even though large power plant facilities have been maintained well, small equipment for detached houses has been rarely maintained. Therefore, the purpose of this study is to analyze maintenance effectiveness of photovoltaic equipment for detached houses. It was analyzed that photovoltaic equipments were merely maintained. What is the most important in maintenance effectiveness is increase of power generation. It was estimated that if photovoltaic equipment for detached houses is maintained well, power generation increases by 6.5% at least. That produces the same effect as the additional supply of photovoltaic equipment to 9,700 households. As a result, it is necessary to maximize the effectiveness of the government's budget investment through well maintenance of photovoltaic equipments.

Development of a structure analytic hierarchy approach for the evaluation of the physical protection system effectiveness

  • Zou, Bowen;Wang, Wenlin;Liu, Jian;Yan, Zhenyu;Liu, Gaojun;Wang, Jun;Wei, Guanxiang
    • Nuclear Engineering and Technology
    • /
    • v.52 no.8
    • /
    • pp.1661-1668
    • /
    • 2020
  • A physical protection system (PPS) is used for the protection of critical facilities. This paper proposes a structure analytic hierarchy approach (SAHA) for the hierarchical evaluation of the PPS effectiveness in critical infrastructure. SAHA is based on the traditional analysis methods "estimate of adversary sequence interruption, EASI". A community algorithm is used in the building of the SAHA model. SAHA is applied to cluster the associated protection elements for the topological design of complicated PPS with graphical vertexes equivalent to protection elements.

Cost Scaling Factor according to Power Plant Capacity Change (발전소 용량변경에 따른 비용보정계수)

  • Ha, Gak-Hyeon;Kim, Sung-Hwan
    • Journal of Energy Engineering
    • /
    • v.22 no.3
    • /
    • pp.283-286
    • /
    • 2013
  • The existing nuclear power plants have been often redesigned by increasing or decreasing electrical power without changing design concept by the request of utility, economic factors or other factors. When the cost of power plant equipment redesigned by changing reactor power and electrical power is estimated, if its quotation is not available in the market place, cost scaling factor(CSF) applies to the cost of existing plant equipment and then the new-designed equipment cost can be calculated. In this paper, we review CSFs according to plant capacity change cases in United State DOE, EPRI, ABB, SWEC and introduce the results applied to Korean PWR 1000MWe and 1400MWe.

Methodology of Emergency Power System by the Minimum Response Time Based on IEC Standards (IEC규격을 부합화한 최소응답시간에 따른 비상전원시스템의 구축방안)

  • Son, Young-Joo
    • Fire Science and Engineering
    • /
    • v.25 no.2
    • /
    • pp.23-32
    • /
    • 2011
  • When the power outage occurred, the emergency power equipments are demanded instead of disaster prevention and security electric power. However, in domestic area, the rules and regulations of emergency power equipment are different so we use different terminologies. Thus, this paper proposes differences of rules and regulations of emergency power equipment between domestic and foreign countries about terms and concepts. Also, we found some problems of the emergency power equipment. To solve these problems, according to the minimum response time in IEC standards, we suggest five emergency power systems and fire load classification in this paper.