• 제목/요약/키워드: Power dissipation

검색결과 868건 처리시간 0.025초

직렬연결된 초전도 한류기의 분로저항에 의한 동작특성 (Operating Characteristics of Superconducting Fault Current Limiters Connected in Series by Shunt Resistors)

  • 현옥배;최효상;김혜림;임해룡;김인선
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권11호
    • /
    • pp.737-741
    • /
    • 2000
  • We fabricated resistive superconducting fault current limiters (SFCL) based on YBCO thin films grown on 2-inch diameter $Al_2O_3$ substrates. Two SFCLs with nearly identical properties were connected in series to investigate simultaneous quench. There was a slight difference in the rate of voltage increase between two SFCL units when they were operated independently. This difference resulted in significantly imbalanced power dissipation between the units. This imbalance was removed by connecting a shunt resister to an SFCL in parallel. The appropriate values of shunt resistance were 80 ${\Omega}$ at 75 $V_rms$ and 110 ${\Omega}$ at 120 $V_rms$, respectively. Increased power input at high voltages also reduced the initial imbalance in power dissipation, but with increase in film temperature to higher than 200 K.

  • PDF

Modeling and Investigation of Multilayer Piezoelectric Transformer with a Central Hole for Heat Dissipation

  • Thang, Vo Viet;Kim, In-Sung;Jeong, Soon-Jong;Kim, Min-Soo;Song, Jae-Sung
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권5호
    • /
    • pp.671-676
    • /
    • 2011
  • A multilayer square-type piezoelectric transformer with a hole at the center was investigated in this paper. Temperature distribution at the center was improved by using this construction, therefore increasing input voltage and output power. This model was simulated and investigated successfully by applying a finite element method (FEM) in ATILA software. An optimized structure was then fabricated, examined, and compared to the simulation results. Electrical characteristics, including output voltage and output power, were measured at different load resistances. The temperature distribution was also monitored using an infrared camera. The piezoelectric transformer operated at first radial vibration mode and a frequency area of 70 kHz. The 16 W output power was achieved in a three-layer transformer with 96% efficiency and $20^{\circ}C$ temperature rise from room temperature under 115 V driving voltage, 100 ${\Omega}$ matching load, $28{\times}28{\times}1.8mm$ size, and 2 mm hole diameter. With these square-type multilayer piezoelectric transformers, the temperature was concentrated around the hole and lower than in piezoelectric transformers without a hole.

2.5 GHZ SECOND-AND FOURTH-ORDER INDUCTORLESS RF BANDPASS FILTERS

  • Thanachayanont, Apinunt
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -1
    • /
    • pp.86-89
    • /
    • 2002
  • A new design approach for realising low-power low-voltage high-Q high-order RE bandpass filter is proposed. Based on the gyrator-C inductor topology, a 2$\^$nd/-order biquadratic bandpass filter can be realised by adding a series capacitor to the input port of the gyrator. High-Q 2$\^$nd/-order and 4$\^$th/-order fully differential RF bandpass filters operating in the 2.4-㎓ ISM (Industrial, scientific and medical) frequency band under a 2-V single power supply voltage with low power dissipation are reported.

  • PDF

Evaluation of Bit-Pipelined Array Circuits for Datapath DSP Applications

  • Israsena, Pasin
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -2
    • /
    • pp.1280-1283
    • /
    • 2002
  • This paper discusses issues in VLSI design and implementation of high performance datapath circuits. Of particular concern will he various types of multiplier and adder, which are fundamental to DSP operations. Performance comparison will be provided in terms of sampling speed, layout area, and in particular, power consumption, with techniques that may be applied to reduce power dissipation also suggested. As an example, a low power, high performance recursive filter achieved through bit-level pipelining technique is illustrated

  • PDF

저전력 다기능 센서시스템 A/D Converter (The A/D Converter for Low Power Multifunctional Sensor System)

  • 박창규;김정규;이지원;김수성;최규훈
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 II
    • /
    • pp.1019-1022
    • /
    • 2003
  • This paper has proposed a 4- bit 20MHz Flash A/D converter design available analog signal processing and realized its intergrated circuit. The parallel comparison method A/D converter quantized analog signals swiftly using various converters. Also this theme has designed economic power dissipation circuit using a preamplifier of low volt & power CMOS comparator. Also the system was fabricated by Hynix 0.35um CMOS process.

  • PDF

저전력 논리 회로 설계를 위한 커널에 바탕을 둔 precomputation 알고리듬 (A kernel-based precomputation scheme for low-power design fo combinational circuits)

  • 최익성;류승현
    • 전자공학회논문지C
    • /
    • 제34C권11호
    • /
    • pp.12-19
    • /
    • 1997
  • In this paper, we present a logic synthesis algorithm for low powr design fo combinational circuits. The proposed algorithm reduces power dissipation by eliminating unnecessary signal transitions. The proposed algorithm restructures a given circuit by using a kernel as prediction logic in a precomputation-based scheme such that switching activity of circuit can be minimized. Experimental results show that the system is efficient for low power design of combinational circuits.

  • PDF

1.5V 2㎓ 저전력 피크 디텍터의 설계 (A 1.5V 2㎓ Low-Power Peak Detector)

  • 박광민
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(2)
    • /
    • pp.149-152
    • /
    • 2001
  • In this paper, a 1.5V 2㎓ low-power peak detector is presented. Analyzing the designed peak detector circuit which is composed with two NMOSs, two diodes, and two capacitors, the detection characteristic relationships are derived. The simulation results with SPICE for 2㎓ pulse signals and sinusoidal signals on the 1.5V supply voltages show the good detection characteristics for input signal levels of 50㎷~500㎷, and show very small power dissipation of 0.332㎽.

  • PDF

저전압 저전력 선형 트랜스컨덕터에 관한 연구 (A Study of Low-Voltage Low-Power Linear Transconductor)

  • 김동용;신희종;차형우;정원섭
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 추계종합학술대회 논문집
    • /
    • pp.967-970
    • /
    • 1999
  • A novel linear transconductor for low-voltage low-power signal processing is proposed. The transconductor consists of a pnp differential-pair and a npn differential-pair which are biased by local negative feedback. The simulation results show that the transcondcutor with transconductance of 50 $mutextrm{s}$ has a linearity error of 0.05% and the power dissipation is 2.44 ㎽ over an input linear range from -2V to +2V at supply voltage $\pm$3V.

  • PDF

Under Water Sonar Transducer Using Terfenol-D Magnetostrictive Material

  • Son, Derac;Cho, Yuk
    • Journal of Magnetics
    • /
    • 제4권3호
    • /
    • pp.98-101
    • /
    • 1999
  • In this work we htave constructed an under water sonar transducer using Terfenol-D rod employing open magnetic circuit. Normally Sonar transducer using Terfenol-D was designed under closed magnetic flux return path, and permanent magnet for dc bias marnetic field, but high magnetic field should be applied to the transducer coil for high sound power and it brings temperature increase inside of the transducer. To improve this heat dissipation problem, we have designed an open magnetic circuit type transducer and we can get 200 dB (re. 1 Pa @ 1m) sound power for the input power of 650 VA.

  • PDF

Field monitoring of splitting failure for surrounding rock masses and applications of energy dissipation model

  • Wang, Zhi-shen;Li, Yong;Zhu, Wei-shen;Xue, Yi-guo;Jiang, Bei;Sun, Yan-bo
    • Geomechanics and Engineering
    • /
    • 제12권4호
    • /
    • pp.595-609
    • /
    • 2017
  • Due to high in-situ stress and brittleness of rock mass, the surrounding rock masses of underground caverns are prone to appear splitting failure. In this paper, a kind of loading-unloading variable elastic modulus model has been initially proposed and developed based on energy dissipation principle, and the stress state of elements has been determined by a splitting failure criterion. Then the underground caverns of Dagangshan hydropower station is analyzed using the above model. For comparing with the monitoring results, the entire process of rock splitting failure has been achieved through monitoring the splitting failure on side walls of large-scale caverns in Dagangshan via borehole TV, micro-meter and deformation resistivity instrument. It shows that the maximum depth of splitting area in the downstream sidewall of the main power house is approximately 14 m, which is close to the numerical results, about 12.5 m based on the energy dissipation model. As monitoring result, the calculation indicates that the key point displacement of caverns decreases firstly with the distance from main powerhouse downstream side wall rising, and then increases, because this area gets close to the side wall of main transformer house and another smaller splitting zone formed here. Therefore it is concluded that the energy dissipation model can preferably present deformation and fracture zones in engineering, and be very useful for similar projects.