• Title/Summary/Keyword: Power density

Search Result 4,516, Processing Time 0.032 seconds

Assessment of stress in virtual reality environment using power spectral density ratio and second derivative of photoplethysmography (광 혈류 신호의 주파수 파워 특성과 이차 미분값을 이용한 가상환경의 스트레스 평가)

  • Y.H. Nam;Kim, H.T.;H.D. Ko;Park, K.S.
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2001.11a
    • /
    • pp.169-172
    • /
    • 2001
  • There are many people who suffer from simulation sickness when immersing in virtual reality. In this study, we analyzed two photoplethysmogram(PPG) parameters - a second derivative parameter and power spectral density ratios - in order to relate PPG parameters with simulation sickness. 36 young, healthy subjects were participated in the experiment, and each subject was equipped with a PPG electrode during his or her immersion. Simulation sickness section was defined as a 7 - second section which starts from the point where a subject reported simulation sickness, and normal section as a same-length section where no physical stimuli was presented to him or her. We compared the PPG parameters of the simulation sickness sections with the normal sections, - d/a ratio is believed to have lower value during vasodilation and higher value during vasoconstriction, however, we could not find much difference in the parameter between normal and simulation sickness sections. We also compared 1 to 10Hz power spectral density ratios in normal sections with in simulation sickness section, and found that 6 density ratios among them have different value. Therefore, the density ratios might be utilized as parameters to detect simulation sickness of subjects.

  • PDF

High Power Factor Three Phase Rectifier for High Power Density AC/DC Conversion Applications

  • Cho, J.G.;Jeong, C.Y.;Baek, J.W.;Song, D.I.;Yoo, D.W.
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.648-653
    • /
    • 1998
  • The conventional three-phase rectifier with bulky LC output filter has been widely used in the industry because of its distinctive advantages over the active power factor correction rectifier such as simple circuit, high reliability, and low cost. Over than 0.9 power factor can be achieved, which is acceptable in most of industry applications. This rectifier, however, is not easy to use for high power density applications since the LC filter is bulky and heavy. To solve this problem, a new simple rectifier is presented in this paper. By eliminating the bulky LC filter from the conventional diode rectifier without losing most of the advantages of the conventional rectifier, very high power density power conversion with high power factor can be achieved. Operation principle and design considerations are illustrated and verified by Pspice simulation and experimental results from a prototype of 3.3 kW rectifier followed by 100KHz zero voltage switching full bridge PWM converter

  • PDF

Minimum Density Power Divergence Estimator for Diffusion Parameter in Discretely Observed Diffusion Processes

  • Song, Jun-Mo;Lee, Sang-Yeol;Na, Ok-Young;Kim, Hyo-Jung
    • Communications for Statistical Applications and Methods
    • /
    • v.14 no.2
    • /
    • pp.267-280
    • /
    • 2007
  • In this paper, we consider the robust estimation for diffusion processes when the sample is observed discretely. As a robust estimator, we consider the minimizing density power divergence estimator (MDPDE) proposed by Basu et al. (1998). It is shown that the MDPDE for diffusion process is weakly consistent. A simulation study demonstrates the robustness of the MDPDE.

Iterative Image Restoration Algorithm Using Power Spectral Density (전력밀도 스펙트럼을 이용한 반복적 영상 신호 복원 알고리즘)

  • 임영석;이문호
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.24 no.4
    • /
    • pp.713-718
    • /
    • 1987
  • In this paper, an iterative restoration algorithm from power spectral density with 1 bit sign information of real part of two dimensional Fourier transform of image corrupted by additive white Gaussian noise is proposed. This method is a modified version of image reconstruction algorithm from power spectral density. From the results of computer simulation with original 32 gray level imgae of 64x64 pixels, we can find that restorated image after each iteration converge to original image very fast, and SNR gain be at least 8[dB] after 10th iteration for corrupted image with additive white Gaussian noise.

  • PDF

Pulse-Grouping Control Method for High power Density DC/DC Converters

  • Kang, Shin-Ho;Jang, Jun-Ho;Lee, Jun-Young
    • Journal of the Semiconductor & Display Technology
    • /
    • v.6 no.2 s.19
    • /
    • pp.45-48
    • /
    • 2007
  • The proposed method offers an improved DC/DC converter scheme to increase power density. It is based on half-bridge topology with newly introduced pulse-grouping control method, which helps to reduce the transformer size and the volume of semiconductor devices maintaining high efficiency. Test results with 85W(18.5V/4.6A) design shows that the measured efficiency is 93.5% with power density of $36W/in^3$.

  • PDF

100W On-Board Power Supply Using Flat Transformer (Flat Transformer를 이용한 100W급 On-Board Power Supply)

  • 황치면;송두익;조정구;정창용;홍승대;하태복
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.577-580
    • /
    • 1999
  • High power density on-board power supply is implemented by using flat transformer. In the high frequency switching converters, large leakage inductance increases the switching stress and duty cycle loss, which sometimes limits maximum switching frequency. The flat transformer is designed by using special core structure, which has very low profile and low temperature rise since the thermal loading is spread evenly over a larger area. 100W, 3.3V output on board supply is built and tested and 50.7W/$\textrm{inch}^{3}$ power density is achieved.

  • PDF

High-Power-Density Power Conversion Systems for HVDC-Connected Offshore Wind Farms

  • Parastar, Amir;Seok, Jul-Ki
    • Journal of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.737-745
    • /
    • 2013
  • Offshore wind farms are rapidly growing owing to their comparatively more stable wind conditions than onshore and land-based wind farms. The power capacity of offshore wind turbines has been increased to 5MW in order to capture a larger amount of wind energy, which results in an increase of each component's size. Furthermore, the weight of the marine turbine components installed in the nacelle directly influences the total mechanical design, as well as the operation and maintenance (O&M) costs. A reduction in the weight of the nacelle allows for cost-effective tower and foundation structures. On the other hand, longer transmission distances from an offshore wind turbine to the load leads to higher energy losses. In this regard, DC transmission is more useful than AC transmission in terms of efficiency because no reactive power is generated/consumed by DC transmission cables. This paper describes some of the challenges and difficulties faced in designing high-power-density power conversion systems (HPDPCSs) for offshore wind turbines. A new approach for high gain/high voltage systems is introduced using transformerless power conversion technologies. Finally, the proposed converter is evaluated in terms of step-up conversion ratio, device number, modulation, and costs.

Measurement of Sonobuoy Transmitting Antenna System for Anti-Submarine Warfare

  • Min Kyeong-Sik
    • Journal of electromagnetic engineering and science
    • /
    • v.5 no.2
    • /
    • pp.97-103
    • /
    • 2005
  • This paper describes the measured results of sonobuoy transmitting antenna system for anti-submarine warfare (ASW). Since radiation pattern and power density depend on impedance matching between transmitting RF part and antenna with termination resistance, design of matching circuit is very important for sonobuoy system performance. Matching circuit is designed by Smith chart using control of L and C. In standing wave ratio(SWR) measurement using Network Analyzer, SWR of antenna with matching circuit observed 1.5 below at the assigned VHF band. It shows very excellent performance comparison with conversional product that is used for the same object. The measured vertical and horizontal radiation patterns are also shown the satisfaction of military specifications. A drop out of sonobuoy system on the sea is happened when angle of elevation direction is over 10 degrees, and it is conformed that it takes less than I second return to original signal level. The required electric power density is $83\;mW/m^2$ in the military specification, and measured electric power density is observed over average $110\;mW/m^2$ at all frequency bands.

Design Technique of a Permanent Magnet High-speed Motor for Improving Power Density and Efficiency (영구자석 고속전동기의 출력밀도 및 효율 향상을 위한 설계 기법)

  • Lee, Ki-Doek;Lee, Ju;Lee, Hyung-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.3
    • /
    • pp.425-430
    • /
    • 2014
  • This paper presents a design technique to improve the power density and efficiency of a permanent magnet high-speed motor by using the mono-PM rotor. The suggested model minimized rotor diameter and stack length which have a bad influence on shafting in the high-speed operation. Conventional and suggested motors are analyzed and compared by using FEM(Finite Element Method) to verify the effectiveness. The overall performance such as torque, losses, efficiency and power density and so on are investigated in detail. The results of the analysis deduced that the suggested mono-PM rotor design is superior to the conventional one.

A Study on the Reliability Index and Customer Density of Distribution System (배전계통의 신뢰도 지수와 수용가 밀도에 관한 연구)

  • Bae, In-Su;Kim, Jin-O
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.9
    • /
    • pp.1646-1650
    • /
    • 2011
  • SAIDI(System Average Interruption Duration Index) is the index that signifies the power quality of customers. SAIDI is also used to know how well utilities operate their systems. The annual interruption time in the areas that consists of widely distributed customers, is generally longer than that in the areas that consists of heavily concentrated customers. The Reliability index of huge system is not necessarily better or worse than that of small system, because SAIDI is irrelevant to the total amount of power sold or the total number of customers. This paper proposes a customer density very relevant to SAIDI. The proposed customer density is used to modify the existing SAIDI to more clearly express the service level of power supply. A modified WSAIDI(weighted SAIDI) can be a useful indicator helping utilities improve the reliability of their systems and customers evaluate the service level of receiving power.