• Title/Summary/Keyword: Power demand

Search Result 2,550, Processing Time 0.042 seconds

Optimal Operating Method of PV+ Storage System Using the Peak-Shaving in Micro-Grid System (Micro-Grid 시스템에서 Peak-Shaving을 이용한 PV+ 시스템의 최적 운영 방법)

  • Lee, Gi-hwan;Lee, Kang-won
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.43 no.2
    • /
    • pp.1-13
    • /
    • 2020
  • There are several methods of peak-shaving, which reduces grid power demand, electricity bought from electricity utility, through lowering "demand spike" during On-Peak period. An optimization method using linear programming is proposed, which can be used to perform peak-shaving of grid power demand for grid-connected PV+ system. Proposed peak shaving method is based on the forecast data for electricity load and photovoltaic power generation. Results from proposed method are compared with those from On-Off and Real Time methods which do not need forecast data. The results also compared to those from ideal case, an optimization method which use measured data for forecast data, that is, error-free forecast data. To see the effects of forecast error 36 error scenarios are developed, which consider error types of forecast, nMAE (normalizes Mean Absolute Error) for photovoltaic power forecast and MAPE (Mean Absolute Percentage Error) for load demand forecast. And the effects of forecast error are investigated including critical error scenarios which provide worse results compared to those of other scenarios. It is shown that proposed peak shaving method are much better than On-Off and Real Time methods under almost all the scenario of forecast error. And it is also shown that the results from our method are not so bad compared to the ideal case using error-free forecast.

Sensitivity Analysis of Temperature on Special Day Electricity Demand in Jeju Island (제주도의 특수일 전력수요에 대한 기온 민감도 분석)

  • Jo, Se-Won;Park, Rae-Jun;Kim, Kyeong-Hwan;Kwon, Bo-Sung;Song, Kyung-Bin;Park, Jeong-Do;Park, Hae-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.8
    • /
    • pp.1019-1023
    • /
    • 2018
  • In this paper sensitivity analysis of temperature on special day electricity demand of land and Jeju Island is performed. The basic electricity demand per 3 hours is defined as electricity demand that reflects the GDP effect without the temperature influence. The temperature sensitivity per 3 hours is calculated through the relationship between special day electricity demand normalized to basic electricity demand and temperature. In the future, forecast error will be improved if the temperature sensitivity per 3 hours is applied to the special day load forecasting.

Implementation of Multi-Channel Power Components Measuremen System (다채널 전력분석시스템의 구현)

  • Lee, Myung-Un;Yoo, Jae-Geun;Lee, Sang-Ick;Cho, Myung-Hyun;Choe, Gyu-Ha
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.3
    • /
    • pp.233-238
    • /
    • 2006
  • In order to solve power disturbances, power components measurement for both supply and demand side of power system must be implemented. This paper proposed a DSP (Digital Signal Processor)-based multi-channel (voltage 8-channel and current 10-channel) power components measurement system that simultaneously can measure and analyze power components for both supply md demand side. After voltage and current measurement accuracy revision using YOKOGAWA 2558, the developed system was tested in the field.

A Case Study on the Chungsong Pumped-storage power station Construction (청송 양수발전소 시공사례)

  • Hong, Chang-Soo;Lee, Hyun-Koo;Do, Jong-Youl
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.10a
    • /
    • pp.169-178
    • /
    • 2006
  • The pumped-storage power system is the one of the hydroelectric power systems, generating electricity with hydraulic head difference. In this system, the electricity is produced during the hours of peak demand by using water that has been pumped into an upper reservoir from a lower reservoir during the hours of low demand. Generally, the system consists of an under-ground power house and tunnels such as the headrace, pressure, and tailrace tunnels. The Chungsong pumped-storage power station is the sixth one In the pumped-storage power station in Korea. Both the regional self-government and the population of chungsong -Goon had made a great effort to draw this power station construction into this area. The proposed Chungsong pumped-power station construction project was accepted by the central government as a part of the national electricity plan for the first time in Korea.

  • PDF

Development Of Power Information Management System For Customer Power Manager and Consumer Participation Type Oriented (수용가 전력관리자와 일반 소비자 참여형 전력정보관리시스템 구축)

  • Jung, Hyung-Yong;Yoo, Sang-Bong;Lee, Ki-Chul;Lee, Cheo-Jick
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.3
    • /
    • pp.480-484
    • /
    • 2015
  • As the increasing national power crises due to various environmental factor, power market change is needed more developed and systemized DSM(Demand Side Management) search at DR market. To overcome national power crisis outbreaking every year and manage the eletric power reserve ratio, we need to construct and develop the electric safety manager and general public main oriented national power plant. For the advanced national power demand management system, it is required the application development like OpenAPI, Big Data Acquisition, Web/APP basd on ICT.

Simulation and Data Sampling Modelling for 1000MW Boiler Process (1000MW 보일러 프로세스의 모델링과 데이터 추출 및 시뮬레이션)

  • Park, Doo-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.301-302
    • /
    • 2007
  • Maximum power consumption was up to 6,228kW in the summer of 2007 due to steady development of industry as well as increased demand of individual. Twenty fossil-Fired Thermal Power Plant for 500MW were underconstructed at present. KEPRI(Korea Electric Power Research Institute) manage 'Development of Advanced Fossil-Fired Thermal Power Generation System' project to construct high efficient power plant of 1000MW capacity for preparing increased demand of power. Design of control logic and data sampling were explained and high efficient control logic was simulated in detail in 'The Development of Next Generation Power Plant Instrument and Control System'(sub-project of 'Development of Advanced Fossil-Fired Thermal Power Generation System' project).

  • PDF

Increasing Effect Analysis of the Wind Power Limit Using Energy Storage System in Jeju-Korea (에너지저장장치를 이용한 제주지역 풍력발전 한계용량 증대효과 분석)

  • Kim, Yeong-Hwan;Kim, Se-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.1
    • /
    • pp.81-90
    • /
    • 2014
  • The Jeju-Korea power system is a small-sized network with a system demand ranging from a autumn minimum of 350MW to a summer peak of 716MW. Because Jeju island is well exposed to north-east winds with high speed, applications to connect to Jeju power system are flooded. Considering physical/environmental constraints, Jeju Self-governing Province has also target for the wind power capacity of 1,350MW by 2020. It amounts to two or three times of Jeju average-demand power and wind power limit capacity announced by Korea Power Exchange (KPX) company. Wind farm connection agreements will be signed to maximize utilization of wind resource. In spite of submarine cable HVDC connected to Korea mainland, Jeju power system is independently operated by frequency and reserve control. This study reevaluates wind power limit based on the KPX criteria from 2016 to 2020. First of all wind power generation limit are affected by off-peak demand in Jeju power system. Also the possibility capacity rate of charging wind power output is evaluated by using energy storage system (ESS). As a result, in case of using 110MWh ESS, wind power limit increases 33~55MW(30~50% of ESS), wind power constraint energy decreases from 68,539MWh to 50,301MWh and wind farm capacity factor increases from 25.9 to 26.1% in 2020.

A Study on the Reasonable Power Demand Method and Load Characteristics in Underground Streets (지하상가 부하설비의 사용특성과 전력관리 방안 연구)

  • Kim, Se-Dong;Choi, Do-Hyuk;Ryu, Seung-Gi
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.235-237
    • /
    • 1996
  • This paper shows a reasonable power demand method and load characteristics in underground streets, that was made by the systematic and statistical way considering actual conditions, such as investigated electric equipment capacity, electric power consumption, load characteristics, etc for 13 underground streets.

  • PDF

The Perspective on Real Time Pricing (실시간 요금 제도 및 기술 전망)

  • Yu, In-H.;Lee, Jin-K.;Kim, Sun-I.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.435-437
    • /
    • 2002
  • This Paper presents the technical perspective on the Real Time Pricing(RTP). So far customer has no control on the electricity pricing. But the price hike in California makes changes in the electricity demand and pricing. In such environments. RTP has become an important role in Demand Side Management. Here the system configuration, advantages of RTP are described. Also the relationship between RTP and AMR is considered.

  • PDF

Current Status of the Feeder Demand Factor in Small Size Apartments (중소형 아파트에서의 전력간선 부하 실태)

  • Lee, Ki-Hong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.116-118
    • /
    • 2004
  • This paper gives a measurement data of the feeder demand factor in small size apartments. The power load measurement data of the feeder shows that the feeders have $10{\sim}30[%]$ margin in capacity. But this margin is not enough to keep up with the trend of power consumption increase from long term standpoint. So it is necessary to measure the feeder power load periodically for the purpose of optimal feeder capacity estimation

  • PDF