• Title/Summary/Keyword: Power control panel

Search Result 191, Processing Time 0.021 seconds

Implementation of an 1/O Card Fault Diagnosis System In Power Plant Simulator (발전소 사뮬레이터 I/O 카드 레벨 고장 진단 시스템의 구현)

  • Byun, S.H.;Ma, B.R.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.3192-3194
    • /
    • 2000
  • Many I/o cards such as AOCs, DICs, DOCs and ROCs are used to deal with I&C instruments of control panel in full-scope power plant simulator. To help the maintenance of I/O cards, an I/o card fault diagnosis system is implemented in this paper. The implemented fault diagnosis system has the automatic fault diagnosis function and manual card test function for fault diagnosis. Finally, the test result using I/O cards shows the validity of the implemented fault diagnosis system.

  • PDF

A Novel Control Algorithm of a Three-phase Four-wire PV Inverter with Imbalance Load Compensation Function

  • Le, Dinh-Vuong;Kim, Chang-Soon;Go, Byeong-Soo;Park, Minwon;Yu, In-Keun
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1131-1137
    • /
    • 2018
  • In this paper, the authors suggest a new control algorithm for a three-phase four-wire photovoltaic (PV) inverter with imbalance load compensation function using conventional proportional-integral (PI) controllers. The maximum power of PV panel is calculated by the MPPT control loop. The reference varying signals of current controllers are transformed to two different rotating frames where they become constant signals. Then simple PI controllers are applied to achieve zero steady-state error of the controllers. The proposed control algorithm are modeled and simulated with imbalance load configuration to verify its performance. The simulation results show that the maximum PV power is transferred to the grid and the imbalance power is compensated successfully by the proposed control algorithm. The inverter has a fast response (~4 cycles) during the transient period. The proposed control algorithm can be effectively utilized to the three-phase four-wire inverter with imbalance load compensation function.

Optimum MPPT Control Period and Perturbation Voltage Analysis for PV Panel based on Real Wether Condition (실제 날씨에 대응한 PV 패널의 최적 MPPT 제어주기와 변량전압 분석)

  • Ryu, Danbi;Kim, Yong-Jung;Kim, Hyosung
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.216-218
    • /
    • 2019
  • 태양광발전시스템은 최대의 전력을 생산하기 위하여 PV 패널의 운전을 최대전력점에서 동작하게 하는 MPPT(Maximum Power Point Tracking) 제어가 필요하다. 그중 대표적인 방법인 P&O(Perturb and Observe) 알고리즘은 전류와 전압을 측정하여 계산된 전력의 값이 최대가 되는 전압의 운전점을 찾는다. 그러나 센서의 측정오차로 인하여 발전전력의 계산 및 전압의 제어에 불규칙한 오차가 발생하여 정확한 MPP 운전점을 찾지 못하는 문제가 발생한다. 본 논문에서는 전형적인 맑은 날씨와 흐린 날씨에서 취득한 일사량 데이터와 전류 및 전압 센서의 오차를 고려하여 P&O 알고리즘에 의한 전력 생산량을 시뮬레이션 한다. 시뮬레이션 분석을 통해 실제 날씨 및 센서허용오차 조건에서 MPPT 목표 효율을 극대화할 수 있는 최적의 MPPT 제어주기와 변량전압의 크기를 제시한다.

  • PDF

A Study on PV AC-Module with Active Power Decoupling and Energy Storage System

  • Won, Dong-Jo;Noh, Yong-Su;Lim, Hong-Woo;Won, Chung-Yuen
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1894-1903
    • /
    • 2016
  • In general, electrolytic capacitors are used to reduce power pulsations on PV-panels. However, this can reduce the reliability of the PV AC-module system, because electrolytic capacitors have a shorter lifetime than PV-panels. In addition, PV-panels generate irregular power and inject it into the grid because the output power of a PV-panel depends on the surrounding conditions such as irradiation and temperature. To solve these problems, a grid-connected photovoltaic (PV) AC-module with active power decoupling and energy storage is proposed. A parallel bi-directional converter is connected to the AC module to reduce the output power pulsations of PV-panels. Thus, the electrolytic capacitor can be replaced with a film capacitor. In addition, the irregular output power due to the surrounding conditions can be regulated by using a parallel energy storage circuit. To maintain the discontinuous conduction mode at low irradiation, the frequency control method is adopted. The design method of the proposed converter and the operation principles are introduced. An experimental prototype rated at 125W was built to verify the performance of the proposed converter.

Habitability evaluation considering various input parameters for main control benchboard fire in the main control room

  • Byeongjun Kim ;Jaiho Lee ;Seyoung Kim;Weon Gyu Shin
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4195-4208
    • /
    • 2022
  • In this study, operator habitability was numerically evaluated in the event of a fire at the main control bench board (MCB) in a reference main control room (MCR). It was investigated if evacuation variables including hot gas layer temperature (HGLT), heat flux (HF), and optical density (OD) at 1.8 m from the MCR floor exceed the reference evacuation criteria provided in NUREG/CR-6850. For a fire model validation, the simulation results of the reference MCR were compared with existing experimental results on the same reference MCR. In the simulation, various input parameters were applied to the MCB panel fire scenario: MCR height, peak heat release rate (HRR) of a panel, number of panels where fire propagation occurs, fire propagation time, door open/close conditions, and mechanical ventilation operation. A specialized-average HRR (SAHRR) concept was newly devised to comprehensively investigate how the various input parameters affect the operator's habitability. Peak values of the evacuation variables normalized by evacuation criteria of NUREG/CR-6850 were well-correlated as the power function of the SAHRR for the various input parameters. In addition, the evacuation time map was newly utilized to investigate how the evacuation time for different SAHRR was affected by changing the various input parameters. In the previous studies, it was found that the OD is the most dominant variable to determine the MCR evacuation time. In this study, however, the evacuation time map showed that the HF is the most dominant factor at the condition of without-mechanical ventilation for the MCR with a partially-open false ceiling, but the OD is the most dominant factor for all the other conditions. Therefore, the method using the SAHRR and the evacuation time map was very useful to effectively and comprehensively evaluate the operator habitability for the various input parameters in the event of MCB fires for the reference MCR.

Validation and Verification Process for the Computerized Procedure System in Nuclear Power Plant Control Room (전자식 절차서 시스템의 원전제어적합성 확인 및 검증절차)

  • Cha, Woo-Chang
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.5 no.1
    • /
    • pp.33-41
    • /
    • 2009
  • The analog or partly digital typed interface of main control room in nuclear power plant (NPP) is gradually being replaced to the totally digitalized interface suitable for the digital environment. SKN 3,4 Nuclear Power Plant is currently developed in such a way to employ advanced displays and controls such as computerized procedure system(CPS), large display panel(LDP), and Soft control. According to the developed design process, the main control room (MCR) of the SKN3,4 was aesthetically designed based on a design concept of the health and sustainability and technically evaluated with human factors guidelines, which somehow lack of the confidence on the evaluation for the rapidly changing digital environment. The suitable review guideline for the digitalized interface and the environment was developed such as the guideline for CPS with information displays on VDU. For the guideline development, tremendous guidelines and technical papers related to evaluation issues of digital environment has been collected, analyzed and transformed to electric database forms and then built on database management system, called Design Review Supporting System to retrieve the appropriate issues for the practical usage of evaluators-in-field.

  • PDF

Development of a Walking-type Solar Panel Cleaning Robot Capable of Driving on Inclined Solar Panel (경사진 패널 위에서 주행이 가능한 보행형 태양광 패널 청소로봇 시스템 개발)

  • Park, Sunggwan;Jang, Woojin;Kim, Dong-Hwan
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.5
    • /
    • pp.79-88
    • /
    • 2020
  • This paper propose the method to drive a solar panel cleaning robot efficiently on an inclined panel using vacuum pad pressure. In this method, the rubber pads using the vacuum pressure are used to attach robot body to the panel surface. By applying the linkage mechanism to the vacuum pads, it was possible to reduce robot weight and power consumption and to prevent slipping of the robot. In addition, the use of solenoid valves, proximity sensors, and encoders to detect movement of the robot body and the control of the pad pressure dedicate to the driving of the robot on an inclined panel. In order to move the robot forward, the operation sequence of multiple solenoid valves was completed, and the six vacuum pads mounted to both legs were accurately controlled to form vacuum and atmospheric pressure in right order so that the robot could move forward without slipping. At last, it was confirmed through experiments that straight-forward moving and rotational movement could be performed up to 36 degrees of inclination angle of solar panel.

Maximum Power Point Tracking Algorithm Development of Photovoltaic by ACM(Approximation Control Method) (ACM에 의한 태양광 발전의 최대전력점 추적 알고리즘 개발)

  • Ko, Jae-Sub;Choi, Jung-Sik;Jung, Chul-Ho;Jung, Byung-Jin;Kim, Do-Yeon;Chung, Dong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2008.04a
    • /
    • pp.215-216
    • /
    • 2008
  • This paper is proposed a approximation control method(ACM) for the maximum power of a photovoltaic system. It is designed for power systems application and utilities. The proposed Maximum Power Point Tracking(MPPT) control has the advantage to provide a new simple way to approximate the optimal or rated voltage, the optimal or rated current and maximum power rating produced by a solar panel and the photovoltaic inverter. And this straightforward method has the advantage that Pmax and $V_{op}$ can be approximated using the same variable as the dynamic model without using complicate approximations or Taylor series. This paper is proposed MPPT using AMC using weather condition of domestic moderate program technique. This paper is proposed the experimental results to verify the effectiveness of the new methods.

  • PDF

Magnetic Levitated Electric Monorail System for Flat Panel Display Glass Delivery Applications (FPD 공정용 Glass 이송 시스템을 위한 자기부상 EMS의 개발)

  • Lee, Ki-Chang;Moon, Ji-Woo;Koo, Dae-Hyun;Lee, Min-Cheol
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.6
    • /
    • pp.566-572
    • /
    • 2011
  • In recent semiconductor and FPD (Flat Panel Display) manufacturing processes, high clean-class delivery operation is required more and more for short working time and better product quality. Traditionally SLIM (Single-sided Linear Induction Motor) is widely used in the liner drive applications because of its simplicity in the rail structure. A magnetically levitated (Maglev) unmanned vehicle with SLIM traction, which is powered by a CPS (Contactless Power Supply) can be a high precision delivery solution for this industry. In this paper unmanned FPD-carrying vehicle, which can levitate without contacting the rail structure, is suggested for high clean-class FPD delivery applications. It can be more acceptable for the complex facilities composed with many processes which require longer rails, because of simple rail structure. The test setup consists of a test vehicle and a rounded rail, in which the vehicle can load and unload products at arbitrary position commanded through wireless communications of host computer. The experimental results show that the suggested vehicle and rail have reasonable traction servo and robust electromagnetic suspensions without any contact. The resolution of point servo errors in the SLIM traction system is accomplished under 1mm. The maximum gap error is ${\pm}0.25mm$ with nominal air gap length of 4.0mm in the electromagnetic suspensions. This type of automated delivery vehicle is expected to have significant role in the clean delivery like FPD glass delivery.

Development of Smart Kiosk for Controlling and Monitoring (제어 및 모니터링을 위한 스마트 키오스크 개발)

  • Kim, Jin-Sa
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.2
    • /
    • pp.160-164
    • /
    • 2022
  • In this paper, through the development of a smart panel (LCD kiosk) controller, contents to develop a system that can be operate in a desired environment by operating the window control and ventilation facilities according to the automatic controller operation based on the set values such as temperature, humidity, sunlight, and rainfall. In particular, the MQTT protocol-based sensor module can be directly manufactured and applied at any time based on various communication and power sources such as wireless, wired, and PLC (power line communication) to obtain the desired data, as well as fire, power failure, and intrusion in the house. It is also a system that enables operation and monitoring from a remote location based on the cloud environment by connecting sensors. Kiosks are currently being used in many places, and the demand for them is on the rise, and an active influx of young people can be expected through environmental improvement. It is expected to increase interest and understanding for improvement.