3-레벨 컨버터에 의한 직류전력제어 (DC Power Control for 3-Level Converter.)

  • 정연택;이사영;함년근
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1996년도 창립기념 전력전자학술발표회 논문집
    • /
    • pp.126-129
    • /
    • 1996
  • This paper study on the control method of 3-level converter. The control of converter is composed of active power control for controlling a output voltage and of reactive power control for high power factor drives. And also, output central voltage is controlled by sensing a each condensor voltage of bank connected the part of dc.

  • PDF

제주 풍력발전 단지의 V47-660 kW 시스템의 역률개선에 관한 연구 (A Study on the Power Factor Improvement of V47-660 kW Wind Turbine Generation System in Jeju Wind Farm)

  • 김일환;전영진;김정웅;강경보;허종철;김건훈
    • 한국태양에너지학회 논문집
    • /
    • 제23권3호
    • /
    • pp.45-53
    • /
    • 2003
  • This paper presents a study on the power factor improvement of V47- 660 [kW] Wind Turbine Generation System (WTGS) in Jeju wind farm, as a model system in this paper. In this system, the power factor correction is controlled by the conventional method with power condensor banks. Also, this system has only four bank steps, and each one capacitor bank step is cut in every one second when the generator has been cut in. This means that it is difficult to compensate the reactive power exactly according to the variation of them. Actually, model system has very low power factor in the area of low wind speed, which is almost from 4 to 6 [m/s]. This is caused by the power factor correction using power condenser bank. To improve the power factor in the area of low wind speed, we used the static var compensator(SVC) using current controlled PWM power converter using IGBT switching device. Finally, to verify the proposed method, the results of computer simulation using Psim program are presented to support the discussions.

345kV CV 케이블 접속함의 Proto Type 선정 (Determination of Proto Type for 345kV CV Cable Accessories)

  • 이수길;김인태;손시호;최수걸;허근도;박완기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1629-1631
    • /
    • 1998
  • Crosslinked polyethylene (XLPE) insulated cables are now widely used all over the world for extra-high voltage underground transmission systems. Prefabricated type (compression type) joint has developed in order to shorten the assembly time and lower the possibility of contamination at site by many companies in the world. For outdoor termination, to control the electric field distribution as uniform as possible, especially for the use of extra-high voltage system. much of products are adopting the oil-impregnated condensor cone type instead of electric field control element which uses the permitivity of it only (not capacitance). For Gas-immersed termination, dimension of outer insulation bushing was determined by IEC Publication 859. The highest voltage of underground power cable system is 345kV now, in Korea. We have much of experiences of the development of prefabricated type accessories for CV cable systems (154kV, 161kV, 230kV level). So it was possible to inspect the proto type of accessories for 345kV CV cable system and seems that the need time for the development of products is reduced.

  • PDF

직접접촉식 응축기를 통한 가압순산소 연소 배가스 내 SOx, NOx 동시저감 연구 (Simultaneous Removal of SOx and NOx in Flue Gas of Oxy-fuel Combustion by Direct Contact Condenser)

  • 최솔비;목진성;양원;류창국;최석천
    • 청정기술
    • /
    • 제25권3호
    • /
    • pp.245-255
    • /
    • 2019
  • 가압순산소 연소는 발전 공정의 온실가스 포집 기술의 하나로서, $CO_2$의 압축 전 단계에 FGC (Flue gas condensor)를 통해 배가스 내 수분의 잠열을 회수하여 효율을 높일 수 있다. 또한 FGC는 가스의 용해도를 이용하여 $SO_x$$NO_x$를 동시에 효과적으로 제거할 수 있는 장점이 있다. 이 연구에서는 FGC의 방식 중 하나로서 직접 접촉식 응축기를 고안하여 $SO_x$$NO_x$의 저감율을 평가하였다. 특히 가스가 물에 직접 통과할 때 용해를 통한 저감효율을 측정하기 위해 단독가스와 혼합가스로 분리하여 상압에서 10 bar까지의 압력조건을 변수로 실험을 진행하였다. 단독 가스 실험결과 $NO_x$는 상압에서 저감율이 약 20%, 10 bar 압력조건에서 약 76%로 크게 증가하였다. 또한 $SO_2$는 높은 용해도로 전량이 용해하여 초기 저감율에 큰 차이가 나타나지 않았으나, 압력이 증가할수록 최고 저감율이 유지되는 시간이 증가하였다. 동시저감 실험 결과 상압에서 $NO_x$의 저감율은 13%이나, 압력이 상승할수록 헨리법칙에 의한 용해도 증가에 따라 20 bar에서 56%로 증가하였다. $SO_2$는 초기에 다량 용해된 후 다시 배출 농도가 증가하는 폭이 상압에서는 1,219 ppm, 20 bar에서는 165 ppm으로 감소하였다. 결론적으로 $NO_x$$SO_x$ 모두 압력이 높아질수록 저감율이 증가하였으나, 단독가스 실험과 비교하면 저감율이 감소함을 확인하였다. 이는 혼합가스 투입으로 인해 반응기 내부에 채운 물의 산성화가 빠르게 이루어졌기 때문이다.