• Title/Summary/Keyword: Power capacitor

Search Result 1,923, Processing Time 0.025 seconds

Comparative Analysis of Pulse Width Modulation Methods for Improving the Lifetime of DC-link Capacitors of NPC Inverters (NPC 인버터의 DC-link 커패시터 수명 향상을 위한 전압 변조 방법 비교 평가)

  • Choi, Jae-Heon;Choi, Ui-Min
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.4
    • /
    • pp.291-296
    • /
    • 2022
  • Capacitor is one of the reliability-critical components in power converters. The lifetime of the capacitor decreases as the operating temperature increases, and power losses caused by capacitor current are the main cause of the capacitor temperature increase. Therefore, various studies are being conducted to improve the lifetime of the capacitor by reducing the current of DC-link capacitors. In this study, pulse width modulation methods proposed for improving the lifetime of DC-link capacitors of the three-level NPC inverter are comparatively analyzed. The lifetime evaluation of the DC-link capacitor under different modulation methods is performed at component level first and then system level by considering all capacitors by applying Monte Carlo simulation. Furthermore, their effects on the efficiency and THD of the output current are also considered.

A Development of Ethernet-Based Remote Diagnosis System for DC Voltage Smoothing Capacitor using DSP (DSP를 적용한 전력용 DC 평활 커패시터의 이더넷 원격 고장진단시스템 개발)

  • Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.2
    • /
    • pp.94-98
    • /
    • 2011
  • Electrolytic power capacitors today form essential components for virtually any power electronic system such as DC/DC converter or UPS. Frequently, electrolytic capacitors for DC link voltage smoothing are the key components which determine the life cycle of the whole unit and often are responsible for converter breakdown failures. In this paper, ethernet-based remote diagnosis system for DC voltage smoothing capacitor using DSP control board is developed. To estimate the status of the capacitor, the equivalent series resistor(ESR) of the component has to be determined. The ESR detection scheme is based on the determination of the capacitor ripple power losses calculated from DC link voltage/current measurement. Experimental results show the veridity and reliability of the proposed ethernet-based remote on-line capacitor diagnosis system.

On-line Failure Detection Method of DC Output Filter Capacitor in Power Converters (전력변환장치에서의 DC 출력 필터 커패시터의 온라인 고장 검출기법)

  • Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.483-489
    • /
    • 2009
  • Electrolytic capacitors are used in variety of equipments as smoothening element of the power converters because it has high capacitance for its size and low price. Electrolytic capacitors, which is most of the time affected by aging effect, plays a very important role for the power electronics system quality and reliability. Therefore it is important to estimate the parameter of an electrolytic capacitor to predict the failure. This objective of this paper is to propose a new method to detect the rise of equivalent series resistor(ESR) in order to realize the online failure prediction of electrolytic capacitor for DC output filter of power converter. The ESR of electrolytic capacitor estimated from RMS result of filtered waveform(BPF) of the ripple capacitor voltage/current. Therefore, the preposed online failure prediction method has the merits of easy ESR computation and circuit simplicity. Simulation and experimental results are shown to verify the performance of the proposed on-line method.

Characteristics Analysis of Power Capacitor at Sag & Swell (순간적인 전압강하 및 순간 전압 융기 발생시 전력용 커패시터의 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Kim, Il-Jung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.10
    • /
    • pp.21-28
    • /
    • 2009
  • Power capacitor has been used to compensate for the low power factor of inductive load and to reduce harmonics generated by the power conversion device with reactor. Power quality is mainly referred to the voltage quality and it is very important for the stable operation of load. But if voltage rms is temporary changed, it acts on capacitor as an electrical stress. In this paper, we analyzed that capacitor can be given by voltage, current and capacity's variance under the sag and swell condition. If reactor is connected at capacitor, sag can be aside from the question. But it can act an amount of stress on capacitor in the swell region.

A Study on the Characteristic of Capacitor by Voltage and Current Harmonics (전압 및 전류 고조파에 의한 커패시터 동작 특성)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Dong-Ju;Lee, Eun-Woong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.3
    • /
    • pp.257-262
    • /
    • 2009
  • Capacitor is basically used for the power-factor compensation and sometimes as the passive filter to reduce harmonics of nonlinear load. Since the impedance of capacitor is inversely proportional to the frequency. The harmonic current may result in the problems of voltage distortion and resonance. Capacitor has easily fall under by two harmonic components, a nonlinear load and a distorted utility voltage. The amplified harmonic current and voltage may damage power capacitor. Hence the pre-investigation of harmonic is needed before designing and application the power factor for reducing fault rate. In this paper, we analyzed that voltage and current with harmonics components act on the capacitor under the resonance condition. we concluded that both voltage and current harmonics have an bad effect on the capacitor and current harmonics is a bitter rather than effect by voltage harmonics.

Design and Control Method for Sub-module DC Voltage Ripple of HVDC-MMC

  • Gwon, Jin-Su;Park, Jung-Woo;Kang, Dea-Wook;Kim, Sungshin
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.921-930
    • /
    • 2016
  • This paper proposes a design and control method for a high-voltage direction current modular multilevel converter (HVDC-MMC) considering the capacitor voltage ripple of the submodule (SM). The capacitor voltage ripple consists of the line frequency and double-line-frequency components. The double line- frequency component does not fluctuate according to the active power, whereas the line-frequency component is highly influenced by the grid-side voltage and current. If the grid voltage drops, a conventional converter increases the current to maintain the active power. A grid voltage drops, current increment, or both occur with a capacitor voltage ripple higher than the limit value. In order to reliably control an MMC within a limit value, the SM capacitor should be designed on the basis of the capacitor voltage ripple. In this paper, the capacitor voltage ripple according to the grid voltage and current are analyzed, and the proposed control method includes a current limitation method considering the capacitor voltage ripple. The proposed design and control method are verified through simulation using PSCAD/EMTDC.

A Study on the Optimum Selection of the Power Factor Compensation Condenser According to the Improved Efficiency of Induction Motor (유도전동기 효율향상에 따른 역률 보상 콘덴서 최적 선정에 대한 연구)

  • Kim, Jong-Gyeum
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.7
    • /
    • pp.1311-1315
    • /
    • 2016
  • Induction motor requires a rotating magnetic field for rotation. Current required to generate the rotating magnetic field is immediately magnetizing current. This magnetizing current is associated with the reactive power. Induction motor is always required reactive power. If reactive power is supplied only to the power supply side, the power factor is low. Therefore, it is to compensate the power factor by connecting capacitors in parallel to the motor terminal. If the capacitor current is greater than the magnetizing current of the motor, there is a possibility that the self-excitation occurs. High voltage generated by the self-excitation leads to insulation failure on the motor. So it is necessary to calculate the power factor correction capacitor capacity the most suitable to the extent that the magnetizing current does not exceed the capacitor current. In this study, we first computed the magnetization current and the reactive power of the induction motor and then calculates a limit of the maximum power factor by comparing the magnetizing current and the capacitor current installed in order to achieve the target power factor.

A Virtual RLC Active Damping Method for LCL-Type Grid-Connected Inverters

  • Geng, Yiwen;Qi, Yawen;Zheng, Pengfei;Guo, Fei;Gao, Xiang
    • Journal of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.1555-1566
    • /
    • 2018
  • Proportional capacitor-current-feedback active damping (AD) is a common damping method for the resonance of LCL-type grid-connected inverters. Proportional capacitor-current-feedback AD behaves as a virtual resistor in parallel with the capacitor. However, the existence of delay in the actual control system causes impedance in the virtual resistor. Impedance is manifested as negative resistance when the resonance frequency exceeds one-sixth of the sampling frequency ($f_s/6$). As a result, the damping effect disappears. To extend the system damping region, this study proposes a virtual resistor-inductor-capacitor (RLC) AD method. The method is implemented by feeding the filter capacitor current passing through a band-pass filter, which functions as a virtual RLC in parallel with the filter capacitor to achieve positive resistance in a wide resonance frequency range. A combination of Nyquist theory and system close-loop pole-zero diagrams is used for damping parameter design to obtain optimal damping parameters. An experiment is performed with a 10 kW grid-connected inverter. The effectiveness of the proposed AD method and the system's robustness against grid impedance variation are demonstrated.

Floating Power Supply Based on Bootstrap Operation for Three-Level Neutral-Point-Clamped Voltage-Source Inverter

  • Nguyen, Qui Tu Vo;Lee, Dong-Choon
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.3-4
    • /
    • 2011
  • This paper presents a survey of floating power supply based on bootstrap operation for three-level voltage-source inverters. The floating power supply for upper switches is achieved by the bootstrap capacitor charged during on-time of the switch underneath. Hence, a large number of bulky isolated DC/DC power supplies for each gate driver are reduced. The Pspice simulation results show the behavior of bootstrap devices and the performance of bootstrap capacitor voltage.

  • PDF

Suitability Review for Power Correction Parameter of Induction Motor (유도전동기 역률 보상 파라미터의 적정성 검토)

  • Kim, Jong-Gyeum
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.12
    • /
    • pp.101-109
    • /
    • 2008
  • Induction motor needs reactive power to sustain the electromagnetic field required for rotating. If reactive power is provided by the load side instead of the source side, power factor will be increased. Power factor of induction motor is usually low and needs to be compensated with power capacitor. In domestic regulations, Capacitor capacity for the power factor correction of induction motor should be complied with the recommended value by the motor output. But, at the same output, characteristics of induction motor is different from each other by the rotation speed and is not suitable for application of regular capacitor value regardless of motor's characteristics. In this paper, we compared to each other with the existing value and new proposed value with rotation speed under the same output condition, confirmed that power capacitor capacity is needed to upgrade for the better power factor.