• 제목/요약/키워드: Power cables

Search Result 681, Processing Time 0.023 seconds

Effect of Laminated Polypropylene Paper on the Breakdown Strength of Multi-layer Insulation for HTS Cable

  • Nguyen, Van-Dung;Baek, Seung-Myeong;Kwag, Dong-Soon;Kim, Sang-Huyn
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.87-93
    • /
    • 2004
  • Laminated Polypropylene Paper (LPP) and Kraft paper were used as ac power insulation for conventional cable as well as high temperature superconducting (HTS) cable because of its prominent insulating characteristics. However, researches on the use of LPP/Kraft paper in HTS cables are thinly scattered. In this paper, the effect of laminate polypropylene paper on the breakdown strength of LPP/Kraft multi-layer sample impregnated with liquid nitrogen (LN2)under ac and impulse applied voltage was studied. In addition, the breakdown strength characteristics of LPP and Kraft multi-layer sample were also investigated. It was found from the experimental data that the LPP has higher breakdown strength value than Kraft paper in ac and impulse. Especially in the ac case, the breakdown strength increases as the component ratio of LPP in the LPP/Kraftsample increases and slightly affected by the inserting position of LPP but in impulse case, the breakdown strength strongly depends on the number of LPP and the relative position of LPP.

  • PDF

On-Line Condition Monitoring and Diagnostics of Distribution Equipment (배전반 설비의 온라인 모니터링 및 진단)

  • Yun, Ju-Ho;Im, Wan-Su;Hwang, Jong-Sun;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.525-526
    • /
    • 2007
  • Continuous on-line temperature monitoring provides the means to evaluate current condition of equipment and detect abnormality. It allows corrective measures to be taken to prevent upcoming failure. Continuous temperature monitoring and event recording provides information on the energized equipment's response to normal and emergency conditions. On-line temperature monitoring helps to coordinate equipment specifications and ratings, determine the real limits of the monitored equipment and optimize facility operations. Using wireless technique eliminates any need for special cables and wires with lower installation costs if compared to other types of online condition monitoring equipment. In addition, wireless temperature monitoring works well under difficult conditions in strategically important locations. Wireless technology for on-line condition monitoring of energized equipment is applicable both as standalone system and with an interface with power quality monitoring system.

  • PDF

Dependence of the Partial Discharge Characteristics of Ultra-high Voltage Cable Insulators on the Measuring Temperature

  • Shin, Jong-Yeol;Park, Hee-Doo;Lee, Hyuk-Jin;Lee, Kang-Won;Kim, Won-Jong;Hong, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.5
    • /
    • pp.186-192
    • /
    • 2008
  • Cross linked polyethylene (XLPE) insulators are used as insulation in ultra-high voltage electric power cables. This study investigated the electrical properties of XLPE at different temperatures. The electrical properties of the changing tree phenomenon was examined as a function of temperature applied to the electrical conductors by measuring the partial discharge at $25^{\circ}C$ to $80^{\circ}C$ and applied voltages to the electrodes ranging from 1 kV to 40 kV. The activity of the partial discharge was examined at various temperatures using the K-means distribution. The results revealed the specimen at $80^{\circ}C$ to have the lowest inception voltage and breakdown voltage. In addition, the core of clusters was moved $0^{\circ}$ and $180^{\circ}$ at the positive region and $180^{\circ}$ and $360^{\circ}$ in the negative region in the K-means. The distribution of clusters was concentrated on the inception condition and spread out widely at the breakdown voltage.

Borehole magnetics for the estimation of unknown foundation pile depth (시추공자력계를 이용한 기초파일 근입심도 추정)

  • Jo, Churl-Hyun;Chung, Hyun-Key;Cho, Kwang-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.3 no.2
    • /
    • pp.161-167
    • /
    • 1999
  • There is an increasing need for the estimation of foundation piles whose depths are unknown. Especially in repair and reinforcement works or in safety inspection and assessment to the big structures whose foundations are piles, the accurate information about the depth of foundation piles is one of the most important factors. A borehole magnetic tool has been developed and tested to meet this object. The fundamental base is that there usually exist many re-bars inside the foundation structure such as piles, and these re-bars are ferromagnetic materials which cause strong induced magnetic field comparable to the earth magnetic field. It utilizes flux-gate type magnetometer which measures 3-components of the magnetic field. Taking vertical derivatives of vertical component of the measured magnetic field, we can expect the error limit of estimating the depth of the pile end less than 20 cm in favorable condition. The maximum measurable distance is about 3 m to the pile from the borehole. The field data show that borehole magnetics is one of the most accurate, fast, and reliable methods for this object so far, as long as there is no magnetic materials such as deep located steel pipe or power cables close to the foundation piles.

  • PDF

Field Applicability Assessment of Degradation Diagnosis System for Distribution Power Cables (배전케이블 열화진단 장치의 현장적용성 평가)

  • Lee, Jae-Bong;Kim, Dong-Myung;Song, Il-Keun;Kim, Ju-Yong;Kim, Suk-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1131-1134
    • /
    • 2003
  • 이 논문은 현재 국내에서 사용하고 있는 배전용 케이블 열화진단장치인 완화전류 측정장치의 진단기준 개선을 위한 것이다. 현재까지 사용되던 직류 고전압을 이용한 누설전류 측정법을 대체하기 위해 사용되는 완화전류 측정장치는 국내 배전선로에서 수년간 현장적용을 실시하여 많은 케이블을 교체하였다. 하지만 완화전류 측정을 통해 교체한 케이블의 상태에 대해서는 검증되지 않은 상태이므로 완화전류 측정을 통한 교체기준이 국내 케이블에 적절한지 확인할 필요가 있다. 이는 케이블 유지보수에 있어서 중요한 사항으로서 교체기준이 부적절할 경우 열화진단을 통한 고장방지 목적을 달성할 수 없거나 건전한 케이블을 교체하여 불필요한 예산을 낭비하는 원인이 된다. 본 논문에서는 현장운전중인 선로를 선택하고 열화된 케이블의 절연성능 향상을 위해 실리콘을 주입하였다. 그리고 실리콘 처리후 케이블의 운전시간에 따른 열화진단 결과와 케이블 절연파괴강도를 비교하여 진단장치의 신뢰성을 검증하고자 하였다. 이것은 1년 동안의 현장시험 결과를 정리한 것이다.

  • PDF

A Study on the Economical Installation Method of Fiber Optical Subscriber Network (광 가입자망의 구축 방식별 경제성 연구)

  • Yoo, Kang-Hee;Park, Jong-Soo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.9
    • /
    • pp.1666-1674
    • /
    • 2008
  • In this paper, various forms of technical methods as well as comparison analysis on constructing optical subscriber network were studied to find the most economical installation method in the future. Comparison analysis has been focused on the three popular types of optical subscriber networks in Korea, such as VDSL2, Ethernet-LAN and FTTH-R. A study is conducted on the initial installation investment per subscriber, equipment failure rate as well as power consumption per subscriber. As a results, FTTH-R network will be the most economical method in the future, but a gradual switch which undergoes a UTP-fiber hybrid method as the midway process is preferable in considering the existing installed copper UTP subscriber cables.

Development of Digital Fault Detection Systems for Screening Open and Short of Wire Harness (와이어 하네스 단선 단락 선별을 위한 디지털 고장 검출 시스템 개발)

  • A Ran Kim;Jae Wan Park;Ha Seon Kim;Jae Hoon Jeong;Sun Young Kim
    • Journal of Drive and Control
    • /
    • v.20 no.4
    • /
    • pp.140-149
    • /
    • 2023
  • Wire harness is a component for efficient control when electronic parts are required such as construction machinery and electric vehicles. With emerging issues such as autonomous driving and automation in construction, a wire harness composed of multiple cables has become an essential part because more electronic parts are required. However, when a wire harness failure occurs, systems can be stopped, accidents can occur, and economic damage can be significant. Therefore, in this paper, we developed a digital fault screening system that could easily and quickly diagnose faults in the wire harness. The principle of the developed system was to sequentially send pulse signals to the wire harness and use returned signals to perform fault detection. As a result of diagnosing faults using the developed failure detection system, a detection accuracy of 99.9 % was confirmed through the experiments.

A Study on Malfunction Mode and Failure Rate Properties of Semiconductor by Impact of Pulse Repetition Rate (펄스 반복률에 의한 반도체 소자의 오동작 모드와 고장률에 관한 연구)

  • Park, Ki-Hoon;Bang, Jeong-Ju;Kim, Ruck-Woan;Huh, Chang-Su
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.6
    • /
    • pp.360-364
    • /
    • 2015
  • Electronic systems based on solid state devices have changed to be more complicated and miniaturized as the electronic systems developed. If the electronic systems are exposed to HPEM (high power electromagnetics), the systems will be destroyed by the coupling effects of electromagnetic waves. Because the HPEM has fast rise time and high voltage of the pulse, the semiconductors are vulnerable to external stress factor such as the coupled electromagnetic pulse. Therefore, we will discuss about malfunction behavior and DFR (destruction failure rate) of the semiconductor caused by amplitude and repetition rate of the pulse. For this experiment, the pulses were injected into the pins of general purpose IC due to the fact that pulse injection test enables the phenomenon after the HPEM is coupled to power cables. These pulses were produced by pulse generator and their characteristics are 2.1 [ns] of pulse width, 1.1 [ns] of pulse rise time and 30, 60, 120 [Hz] of pulse repetition rate. The injected pulses have changed frequency, period and duty ratio of output generated by Timer IC. Also, as the pulse repetition rate increases the breakdown threshold point of the timer IC was reduced.

High-Frequency Circuit Modeling of the Conducted-Emission from the LDC System of a Electric Vehicle (전기자동차 LDC 시스템의 전도 방출에 관한 고주파 모델링 연구)

  • Jung, Kibum;Jo, Byeong-Chan;Chung, Yeon-Choon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.8
    • /
    • pp.798-804
    • /
    • 2013
  • In this paper, conducted emission from the LDC(Low-Side DC/DC Converter) of a HEV/EV was analyzed using high-frequency circuit modeling in system-level approach. The conducted emission by PWM process(100 kHz; Switching Frequency) can cause RFI(Radio-Frequency Interference) problems in the AM/FM frequency range. In order to mitigate this conducted emission, a high-frequency equivalent circuit model is proposed by analyzing the fundamental circuits, parasitic components in their parts and connections and non-linear characteristics of MOSFETs, high-power capacitors, inverters, motors, high-power cables, and bus bars which are composed of the LDC. Using these circuit models, results of both simulation and measurement were compared and similarities between them were verified. We are looking forward that this approach can be effectively used in the EMC design of HEV/EV.

Transmission Loss from Voltage Drop in a DC Cable for a Floating Photovoltaic System in a Reservoir (저수지 내 수상태양광의 전압 강하에 의한 직류 송전 손실)

  • Bhang, Byeong Gwan;Woo, Sung Cheol;Lee, Wonbin;Choi, Jin Ho;Shin, SeungWook;Lee, ChulSung;Park, MiLan;Won, Changsub;Ahn, HyungKeun
    • New & Renewable Energy
    • /
    • v.16 no.1
    • /
    • pp.47-57
    • /
    • 2020
  • In Floating PV (Photovoltaic) systems, PV modules are installed on water by utilizing the surface of idle water such as a reservoir and multipurpose dam. A floating PV system, therefore, has the advantage of efficiency in national land use and improved energy yield owing to cooling effect compared to on-land PV systems. Owing to the limitation of installation environment for a floating PV system, the system, however, has the disadvantage of an increase in transmission distance of DC (Direct current) cables. A longer transmission distance of a DC cable results in greater power loss due to a voltage drop. This leads to a decline in economic feasibility for the floating PV system. In this paper, the economic analysis for 10 floating PV systems installed in a reservoir has been conducted in terms of a change in annual power sales according to the variation of transmission losses depending on the factors affecting the voltage drop, such as transmission distance, cross-section area of underwater cable, the presence of joint box, and PV capacity.