• 제목/요약/키워드: Power burden

검색결과 344건 처리시간 0.029초

EMTDC Modeling Method of DC Reactor type Superconducting Fault Current Limiter

  • Lee, Jaedeuk;Park, Minwon;Yu, In-Keun
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권1호
    • /
    • pp.56-59
    • /
    • 2003
  • As electric power systems grow to supply the increasing electric power demand short-circuit current tends to increase and impose a severe burden on circuit breakers and power system apparatuses. Thus, all electric equipment in a power system has to he designed to withstand the mechanical and thermal stresses of potential short-circuit currents. Among current limiting devices, Fault Current Limiter (FCL) is expected to reduce the short-circuit current. Especially, Superconducting Fault Current Limiters (SFCL) offer ideal performance: in normal operation the SFCL is in its superconducting state and has negligible impedance, in the event of a fault, the transition into the normal conducting state passively limits the current. The SFCL using high-temperature superconductors offers a positive resolution to controlling fault-current levels on utility distribution and transmission networks. This study contributes to the EMTDC based modeling and simulation method of DC Reactor type SFCL. Single and three phase faults in the utility system with DC reactor type SFCLs have been simulated using EMTDC in order to coordinate with other equipments, and the results are discussed in detail.

거리측정센서를 이용한 자동주행 전동 휠체어 시스템 (Autonomous Navigation System of Power Wheelchair using Distance Measurement Sensors)

  • 이준
    • 한국정보전자통신기술학회논문지
    • /
    • 제6권3호
    • /
    • pp.174-182
    • /
    • 2013
  • The power wheelchair is an important and convenient mobility device. The demand of power wheelchair is increasing for assistance in mobility. In this paper we proposed a robotic wheelchair for mobility aid to reduce the burden from the disabled. The main issue in an autonomous wheelchair is the automatic detection and avoidance of obstacles and going to the pre-designated place. The proposed algorithm detects the obstacles and avoids them to drive the wheelchair to the desired place safely with panning scan from sensors of distance measurement and fuzzy control. By this way, the disabled will not always have to worry about paying deep attention to the surroundings and his path.

원전 증기발생기 관리프로그램 (Steam Generator Management Program)

  • 조남철;김무수;이광우
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.610-616
    • /
    • 2003
  • Recently, the common concern of nuclear power industry in the development of technology mitigating and preventing the aging of steam generator tubes prevails, because the trends of steam generator flaws at Uljin unit #1,2 and KSNP(Korea Standard Nuclear Power Plant) impose a burden on the operation of nuclear power plant. While the regulatory agency is demanding the establishment of the advanced general performance maintenance system, the steam generator management program adapting advanced technology is being developed which may comply with EPRI PWR SG Guidelines based on NEI 97-06 ‘ General Guidelines including all the maintenance aspects consist of the tube integrity assessment criteria, repair limit, allowable leakage level, water chemistry will be composed in order to obtain the approval of regulatory agency and be applied to Nuclear power plant early 2005. This presentation is to introduce maintenance state including SG tube degradation and main contents of advanced SG management program being developed, and futhermore update present and future plan, and estimate the alternation after the completion.

  • PDF

전력계통에 초전도한류기 적용시 차단용량 확보를 위한 초전도한류기 적용방안 연구 (Analysis on the Application Capacity of the Superconducting Fault Current Limiter considering Reclosing and Fault Current)

  • 김진석;임성훈;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.592-593
    • /
    • 2015
  • Recently, the fault current has increased to exceed the rated breaking capacity of protective device due to the growth of the power demand on the power system where is changed into the loop-, mesh-, network grid. To limit fault current, the superconducting fault current limiter (SFCL) is announced with various methods. In many researches, the current limiting effect with the SFCL has been analyzed considering the rated breaking capacity of the CB with one fault condition. However, the power system has various short circuit and operation conditions. In order to select the capacity of the SFCL with reclosing operation and burden of the fault current on the protective device, the characteristics of the power system were investigated. Through the analysis, the evaluation method of the current rate was improved.

  • PDF

PWM 제어 능동 교류 전력 필터의 개발 및 속도 개선 (Implementation of a PWM Controlled Active AC Power Filter Using a Fast PWM Control Method)

  • 김재현;박인규;박종근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 정기총회 및 창립40주년기념 학술대회 학회본부
    • /
    • pp.457-462
    • /
    • 1987
  • This paper deals with the PWM controlled active AC power filter. A new PWM control method from the viewpoint of speed and simplicity is proposed. And a microprocessor-based controller is used to realize the active AC power filter. The existing PWM control methods are primarily based on Fourier series expansion and these methods need FFT calculation and solving nonlinear harmonic equations, which are heavy burden to real-time control. The proposed method is based upon generalized pulse series expansion and needs only definite integrals of harmonic signal. So, computational effort can be reduced by a large margin. The digital circuit using 16-bit microprocessor is designed to implement the actual active power filler.

  • PDF

Challenges in Green Innovation Policy after the Fukushima Nuclear Accident

  • Wada, Tomoaki
    • STI Policy Review
    • /
    • 제4권1호
    • /
    • pp.135-161
    • /
    • 2013
  • This paper examines Japan's Science and Technology (S&T) Basic Plans in accordance with its S&T Basic Law. The Basic Plans promote two major innovation (Green Innovation and Life Innovation) towards the creation of new markets and jobs, specifically under the Fourth S&T Basic Plan enacted on August 2011. Successful smart community demonstration projects at four urban localities were launched under plans to promote Green Innovation research and development of renewable energy technologies. However, the expectation that renewable energy such as solar or wind power can replace nuclear power is not backed by sufficient evidence. Furthermore, the electricity produced by these sources is expensive and unstable owing to its reliance on weather conditions. The Fukushima nuclear power plant accident on March 2011 has also seriously affected Japan's future energy plans. According to a government estimate, electricity charges would double if nuclear power generation were abandoned, imposing a heavy burden on the Japanese economy. Japan is in need of energy policies designed on the basis of more far-sighted initiatives.

Autonomous Navigation System for Power Wheelchair System

  • 정문수;안성수
    • 한국전자통신학회논문지
    • /
    • 제4권1호
    • /
    • pp.37-45
    • /
    • 2009
  • The power wheelchair is an important and convenient mobility device. The demand of power wheelchair is increasing for assistance in mobility. In this paper we proposed a robotic wheelchair for mobility aid to reduce the burden from the disabled. The main issue in an autonomous wheelchair is the automatic detection and avoidance of obstacles and going to the pre-designated place. The proposed algorithm detects the obstacles and avoids them to drive the wheelchair to the desired place safely with panning scan from sensors of distance measurement and fuzzy control. By this way, the disabled will not always have to worry about paying deep attention to the surroundings and his path.

  • PDF

A Practical Algorithm for Selective Harmonic Elimination in Five-Level Converters

  • Golshan, Farzad;Abrishamifar, Adib;Arasteh, Mohammad
    • Journal of Power Electronics
    • /
    • 제18권6호
    • /
    • pp.1650-1658
    • /
    • 2018
  • Multilevel converters are being widely used in medium-voltage high-power applications including motor drive systems, utility power transmission, and distribution systems. Selective harmonic elimination (SHE) is a well-known modulation method to generate high quality output voltage waveforms. This paper presents a new simple practical method for generating a generalized five-level waveform without selected low order harmonics. This method is based on a phase-shifted expression for the SHE problem, which can analytically calculate the exact values of switching angles and the feasible modulation index range for three-level and five-level waveforms. The proposed method automatically determines the number of transitions between levels and generates proper output waveform without solving complex trigonometric equations. Due to the simplicity of the computational burden, the real-time implementation of the proposed algorithm can be performed by a simple processor. Simulation and experiment results verify the correctness and effectiveness of the proposed method.

디지털 록인 앰프를 이용한 새로운 하이브리드 방식의 단독운전 검출법 (A Novel Hybrid Islanding Detection Method Using Digital Lock-In Amplifier)

  • Ashraf, Muhammad Noman;Choi, Woojin
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 전력전자학술대회
    • /
    • pp.77-79
    • /
    • 2019
  • Islanding detection is one of the most important issues for the distributed generation (DG) systems connected to the power grid. The conventional passive islanding detection methods inherently have a non-detection zone (NDZ), and active islanding detection methods may deteriorate the power quality of a power system. This paper proposes a novel hybrid islanding detection method based on Digital Lock-In Amplifier with no NDZ by monitoring the harmonics present in the grid. Proposed method detects islanding by passively monitoring the grid voltage harmonics and verify it by injecting small perturbation for only three-line cycles. Unlike FFT for the harmonic extraction, DLA HC have lower computational burden, moreover, DLA can monitor harmonic in real time, whereas, FFT has certain propagation delay. The simulation results are presented to highlight the effectiveness of the proposed technique. In order to prove the performance of the proposed method it is compared with several passive islanding detection methods. The experimental results confirm that the proposed method exhibits outstanding performance as compared to the conventional methods.

  • PDF

Coordinated Voltage and Reactive Power Control Strategy with Distributed Generator for Improving the Operational Efficiency

  • Jeong, Ki-Seok;Lee, Hyun-Chul;Baek, Young-Sik;Park, Ji-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1261-1268
    • /
    • 2013
  • This study proposes a voltage and reactive coordinative control strategy with distributed generator (DG) in a distribution power system. The aim is to determine the optimum dispatch schedules for an on-load tap changer (OLTC), distributed generator settings and all shunt capacitor switching on the load and DG generation profile in a day. The proposed method minimizes the real power losses and improves the voltage profile using squared deviations of bus voltages. The results indicate that the proposed method reduces the real losses and voltage fluctuations and improve receiving power factor. This paper proposes coordinated voltage and reactive power control methods that adjust optimal control values of capacitor banks, OLTC, and the AVR of DGs by using a voltage sensitivity factor (VSF) and dynamic programming (DP) with branch-and-bound (B&B) method. To avoid the computational burden, we try to limit the possible states to 24 stages by using a flexible searching space at each stage. Finally, we will show the effectiveness of the proposed method by using operational cost of real power losses and voltage deviation factor as evaluation index for a whole day in a power system with distributed generators.