• 제목/요약/키워드: Power breakdown point

검색결과 47건 처리시간 0.024초

피뢰기를 고려한 자가용 전기설비 인입선로의 직류누설전류시험에 관한 연구 (A Study on the DC Leakage Current Test for Power Cable of Private Electrical Facilities considering Lightning Arrester)

  • 정기석;길형준
    • 전기학회논문지
    • /
    • 제67권1호
    • /
    • pp.142-147
    • /
    • 2018
  • Private electrical facilities are judged whether it is suitable for the insulation aging condition of their incoming underground cables using DC leakage current test method. In the case where the service point of utility is the secondary side of cut out switch installed in the electric pole, there is a problem that it is difficult to separate the lightning arresters(LA) because of their high position of the pole. Therefore, the field test voltage is applied at value lower than DC 30 kV, which are stated in the inspection guideline. However, this test could reduced the insulation performance of the LA by accelerating the electrical stress of the metal oxide varistor element in the pre-breakdown region. In this study, we analyzed the relationship between the DC test voltage and the leakage current using the non-destructive DC high voltage equipment with leakage current measurement function. The results show that the leakage current increases sharply above the specified test voltage. As a consequence, it could be contributed to improve insulation aging inspection method by selecting the possible test area on the VI characteristic curve of the pre-breakdown area of the LA.

345kV 혼합송전선로에서 재폐로가 절연설계에 미치는 영향 (Effects of Reclosing for Insulation Coordination in 345kV Combined Transmission Lines)

  • 이종범;정채균;임광식;강지원
    • 전기학회논문지
    • /
    • 제59권5호
    • /
    • pp.847-853
    • /
    • 2010
  • This paper describes switching surge analysis for reclosing decision in 345kV combined transmission line with XLPE power cable. Reclosing operation should be decided based on the detailed technical analysis in combined transmission line because this line includes power cable section which is week on insulation. Insulation of power cable can be breakdown at the week point in case of reclosing moment. Therefore the detailed analysis has to be carried out by considering several conditions such as length ratio of power cable section, arrestor, inserting resistance, charging rate, grounding resistance, etc.. On the other hand sheath voltage on IJ(Insulated Joint) is analyzed to check dangerous condition on cable cover. Analysis is performed by EMTP/ATP. Analysis results show that reclosing can be operated as the single line-to-ground fault occurs on overhead line in 345kV combined transmission line, if the inserting resistance is considered before the operation of main circuit breaker.

154kV 혼합송전선로 재폐로 결정에 관한 연구 (A Study on Reclosing Decision on 154kV Combined Transmission Lines)

  • 정채균;박흥석;강지원;이종범
    • 전기학회논문지
    • /
    • 제59권10호
    • /
    • pp.1761-1769
    • /
    • 2010
  • This paper describes switching surge analysis on reclosing decision in 154kV combined transmission line with power cables. Reclosing should be operated in combined transmission line based on the technical evaluation because of insulation problem of power cable section. If the surge strikes on power cable, the breakdown can occur at week point of cable insulation. Therefore the detailed analysis is required by considering several conditions such as length ratio of power cable, arrester, fault resistance, charging rate and grounding resistance, etc.. In addition, sheath voltage on IJ(Insulated Joint) is analyzed to confirm the protective level. Simulation is performed by EMTP/ATP. Analysis results show that reclosing can be operated without any special problem by the single line-to-ground fault with fault resistance of $1\Omega$ to $50\Omega$ occurred at the overhead transmission section in 154kV combined transmission lines and trap charge of 100% and 110%.

Electrical Characteristics of Enhancement-Mode n-Channel Vertical GaN MOSFETs and the Effects of Sidewall Slope

  • Kim, Sung Yoon;Seo, Jae Hwa;Yoon, Young Jun;Kim, Jin Su;Cho, Seongjae;Lee, Jung-Hee;Kang, In Man
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1131-1137
    • /
    • 2015
  • Gallium nitride (GaN) is a promising material for next-generation high-power applications due to its wide bandgap, high breakdown field, high electron mobility, and good thermal conductivity. From a structure point of view, the vertical device is more suitable to high-power applications than planar devices because of its area effectiveness. However, it is challenging to obtain a completely upright vertical structure due to inevitable sidewall slope in anisotropic etching of GaN. In this letter, we design and analyze the enhancement-mode n-channel vertical GaN MOSFET with variation of sidewall gate angle by two-dimensional (2D) technology computer-aided design (TCAD) simulations. As the sidewall slope gets closer to right angle, the device performances are improved since a gradual slope provides a leakage current path through the bulk region.

중성자 조사에 의해 생성된 점결함 연구 (A study on point defects induced with neutron irradiation in silicon wafer)

  • 김진현;류근걸
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.62-66
    • /
    • 2002
  • The conventional floating zone(FZ) crystal and Czochralski(CZ) silicon crystal have resistivity variations longitudinally as well as radially The resistivity variations of the conventional FZ and CZ crystal are not conformed to requirement of dopant distribution for power devices and thyristors. These resistivity variations in conventional cystals limits the reverse breakdown voltage that could be achieved and forced designers of high power diodes and thyristors to compromise the desired current-voltage characteristics. So to produce high Power diodes and thyristors, Neutron Transmutation Doping(NTD) technique is the one method just because NTD silicon provides very homogeneous distribution of doping concentration. This procedure involves the nuclear transmutation of silicon to phosphorus by bombardment of neutron to the crystal according to the reaction $^{30}$ Si(n,${\gamma}$)longrightarrow$^{31}$ Silongrightarrow(2.6 hr)$^{31}$ P+$\beta$$^{[-10]}$ . The radioactive isotope $^{31}$ Si is formed by $^{31}$ Si capturing a neutron, which then decays into the stable $^{31}$ P isotope (i.e., the donor atom), whose distribution is not dependent on the crystal growth parameters. In this research, neutron was irradiated on FZ silicon wafers which had high resistivity(1000~2000 Ω cm), for 26 and 8.3hours for samples of HTS-1 and HTS-2, and 13, 3.2, 2.0 hours for samples of IP-1, IP-2 and IP-3, respectively, to compare resistivity changes due to time differences. The designed resistivities were approached, which were 2.l Ωcm for HTS-1, 7.21 Ω cm for HTS-2, 1.792cm for IP-1, 6.83 Ωcm for IP-2, 9.23 Ωcm for IP-3, respectively. Point defects were investigated with Deep Level Transient Spectroscopy(DLTS). Four different defects were observed at 80K, 125K, 230K, and above 300K.

  • PDF

계면을 갖는 PET 필름의 유전특성의 온도 및 주파수 의존성 (Dependencies of Dielectric Properties on Temperature and Frequency in PET films with interfaces)

  • 이창훈;이종복;이동영;강무성;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.938-940
    • /
    • 1998
  • In order to improve insulating character and ability of insulating system of power apparatus, the interfacial and complex structure is widely used. However, the interface or complex structure of insulation materials is reported as a weak point which causes breakdown. As the interface of insulation system degrades its electrical property and eventually causes a failure, the datailed phenomenon analysis is reported. The object of this paper is to evaluate dielectric property of PET film with the interface. The $tan{\delta}$ increased with the existence of semiconducting layer and showed prominent decrease as a function of temperature. Also, the $tan{\delta}$ showed prominent increase as a function of frequency. The dielectric properties of interfacial were affected by the interface characteristics.

  • PDF

풍력 및 태양광 발전시스템의 일반 특성과 강풍제어기 및 DC-DC컨버터에 대한 연구 (A Study on General Characteristics of Wind and Solar Power System, Automatic Tail Safety Controller and DC-DC Converter)

  • 최정훈;박성준;문채주
    • 조명전기설비학회논문지
    • /
    • 제19권1호
    • /
    • pp.109-116
    • /
    • 2005
  • 풍력 및 태양광 발전시스템은 화석에너지의 고갈에 대한 대체에너지로 각광을 받고 있으며, 환경오염을 발생하지 않고 무한정으로 사용할 수 있으나 풍속과 태양광의 변화에 따른 안정성의 문제가 발생한다. 풍력발전시스템의 경우 태풍과 급속한 풍속의 변화에 의해 시스템의 안정성 문제가 발생한다. 본 논문에서는 풍속을 이용한 피드백 제어를 기초로 하는 자동강풍제어기를 포함하는 풍력 발전시스템을 구성하였으며, 이를 다양한 조건의 실험을 통하여 입증하였다. 태양전지 어레이의 최대 출력을 위한 MPPT제어와 고르지 못한 DC 전압을 정류하기 위하여 buck-boost컨버터를 사용하였고, 실험을 동하여 시스템 출력전류 리플 저감의 결과를 확인하였다.

Voltage Stability Prediction on Power System Network via Enhanced Hybrid Particle Swarm Artificial Neural Network

  • Lim, Zi-Jie;Mustafa, Mohd Wazir;Jamian, Jasrul Jamani
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.877-887
    • /
    • 2015
  • Rapid development of cities with constant increasing load and deregulation in electricity market had forced the transmission lines to operate near their threshold capacity and can easily lead to voltage instability and caused system breakdown. To prevent such catastrophe from happening, accurate readings of voltage stability condition is required so that preventive equipment and operators can execute security procedures to restore system condition to normal. This paper introduced Enhanced Hybrid Particle Swarm Optimization algorithm to estimate the voltage stability condition which utilized Fast Voltage Stability Index (FVSI) to indicate how far or close is the power system network to the collapse point when the reactive load in the system increases because reactive load gives the highest impact to the stability of the system as it varies. Particle Swarm Optimization (PSO) had been combined with the ANN to form the Enhanced Hybrid PSO-ANN (EHPSO-ANN) algorithm that worked accurately as a prediction algorithm. The proposed algorithm reduced serious local minima convergence of ANN but also maintaining the fast convergence speed of PSO. The results show that the hybrid algorithm has greater prediction accuracy than those comparing algorithms. High generalization ability was found in the proposed algorithm.

산업설비 EPC 업무 분석을 통한 정보 분류 내역에 관한 연구 (A Study on Information Breakdown through the Analysis of Industrial Engineering EPC Business Process)

  • 조항민;송영웅;최윤기
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2006년도 정기학술발표대회 논문집
    • /
    • pp.167-172
    • /
    • 2006
  • 최근 해외 건설시장 플랜트 분야의 수주 증대에 따라 오일 ${\cdot}$ 가스 분야의 프로젝트가 증가하고 있다. 따라서 국내 건설 산업 업체들의 해외 플랜트 사업의 경쟁력을 확보하기 위해서는 기술 경쟁력 확보, 생산성 향상, 전략적 정영 추진 등 적극적인 대처 방안 수립이 요구되고 있다. 그 중에서도 해외 플랜트 사업의 오일 ${\cdot}$ 가스 분야는 산업 경쟁력 향상을 위하여 프로젝트 수행과 관련한 EPC(Engineering Procurement Construction : 이하 EPC) 유통 정보의 활용이 더욱 요구되지만, EPC 단계별 다양한 업무에서 발생하는 유동정보 콘텐츠를 효율적으로 관리하기 위한 콘텐츠 분류체계가 제시되고 있지 못하고 있다. 그로 인하여 설계도면의 변경, 중복업무의 발생, 업무주체간의 정보 누락 등의 문제점이 발생하고, 그러한 문제점으로 인하여 생산성 저하 현상이 나타나고 있다. 따라서 본 연구는 오일 ${\cdot}$ 가스 분야의 콘텐츠 관리체계의 실무적 활용의 증대와 건설산업 정보관리의 효용성을 향상시키기 위하여 콘텐츠 관리 체계를 확립하기 위한 BPM(Business Process Management) 기반의 콘텐츠 분류 체계를 제시하고자 한다. Business Process별 요구되는 지식의 유형을 체계화하고, 콘텐츠 정보를 분석하여 산업설비 유동정보의 체계화를 정립하고자 한다.

  • PDF

Experimental Investigations on Upper Part Load Vortex Rope Pressure Fluctuations in Francis Turbine Draft Tube

  • Nicolet, Christophe;Zobeiri, Amirreza;Maruzewski, Pierre;Avellan, Francois
    • International Journal of Fluid Machinery and Systems
    • /
    • 제4권1호
    • /
    • pp.179-190
    • /
    • 2011
  • The swirling flow developing in Francis turbine draft tube under part load operation leads to pressure fluctuations usually in the range of 0.2 to 0.4 times the runner rotational frequency resulting from the so-called vortex breakdown. For low cavitation number, the flow features a cavitation vortex rope animated with precession motion. Under given conditions, these pressure fluctuations may lead to undesirable pressure fluctuations in the entire hydraulic system and also produce active power oscillations. For the upper part load range, between 0.7 and 0.85 times the best efficiency discharge, pressure fluctuations may appear in a higher frequency range of 2 to 4 times the runner rotational speed and feature modulations with vortex rope precession. It has been pointed out that for this particular operating point, the vortex rope features elliptical cross section and is animated of a self-rotation. This paper presents an experimental investigation focusing on this peculiar phenomenon, defined as the upper part load vortex rope. The experimental investigation is carried out on a high specific speed Francis turbine scale model installed on a test rig of the EPFL Laboratory for Hydraulic Machines. The selected operating point corresponds to a discharge of 0.83 times the best efficiency discharge. Observations of the cavitation vortex carried out with high speed camera have been recorded and synchronized with pressure fluctuations measurements at the draft tube cone. First, the vortex rope self rotation frequency is evidenced and the related frequency is deduced. Then, the influence of the sigma cavitation number on vortex rope shape and pressure fluctuations is presented. The waterfall diagram of the pressure fluctuations evidences resonance effects with the hydraulic circuit. The influence of outlet bubble cavitation and air injection is also investigated for low cavitation number. The time evolution of the vortex rope volume is compared with pressure fluctuations time evolution using image processing. Finally, the influence of the Froude number on the vortex rope shape and the associated pressure fluctuations is analyzed by varying the rotational speed.