• 제목/요약/키워드: Power boiler

검색결과 516건 처리시간 0.024초

Automatic adjustment of feedforward signal in boiler controllers of thermal power plants

  • Egashira, Katsuya;Nakamura, Masatoshi;Eki, Yurio;Nomura, Masahide
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1995년도 Proceedings of the Korea Automation Control Conference, 10th (KACC); Seoul, Korea; 23-25 Oct. 1995
    • /
    • pp.83-86
    • /
    • 1995
  • This paper proposes an auto-tuning method of feedforward signal in boiler control of thermal power plants by using the neural network. The neural network produces an optimal feedforward signal by tuning the weights of the network. The weights are adapted effectively by using the teaching signal of PI control output. The proposed method was evaluated based on a detailed simulator which expressed non-linear characteristics of the 600 MW actual thermal power plant at load chaning operations, showed effectiveness in the learning of the weights of the neural network, and gave an accurate control performance in the temperature control of the system. Through the evaluation, the proposed method was proved to be effectively applicable to the actual thermal plants as the automatic adjustment tool.

  • PDF

화력 발전소 보일러 드럼수위 제어기의 자동 동조 (Auto-tuning of boiler drum level controller in Thermal Power Plant)

  • 이주현;주영호;변승현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.2584-2586
    • /
    • 2000
  • A drum level control is one of the most important control systems in thermal power plant. The control objective of drum level of boiler in thermal power plant is to maintain drum level at constant set-point regardless of disturbance such as main steam flow. The implemented drum level controller is the cascade PI controller. The important factor in drum level controller is the parameters of two PI controllers. The tuning of PI controller parameter is tedious and time-consuming job. In this paper, the relay feedback Ziegler - Nichols tuning method extended to auto-tune cascade PI drum level controller. Finally, the simulation result using boiler model in Power Plant shows the validity of auto-tuned cascade PI controller.

  • PDF

보일러-터빈 제어시스템의 측정기 고장검출 (A Sensor Fault Detection for Boiler-Turbine Control System)

  • 류석환
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제14권1호
    • /
    • pp.37-43
    • /
    • 2014
  • This paper deals with a design of observer based fault detection filter for a boiler-turbine control system. The goal is to present a method for rapid sensor fault detection in order to enhance the reliability of boiler-turbine operation in the thermal power plant. Our fault detection filter can be designed via solutions of linear matrix inequalities. In order to demonstrate the efficacy of our design method, numerical simulations are provided.

대용량 미분탄 보일러의 연소특성 및 NO 분포 특성 연구 (Studies on the Combustion Characteristics and NO Distribution in the Pulverized Coal Fired Boiler)

  • 박호영;김영주
    • 대한환경공학회지
    • /
    • 제30권5호
    • /
    • pp.552-559
    • /
    • 2008
  • 접선 연소식 미분탄 보일러의 연소특성 분석을 위한 3차원 전산해석 연구를 수행하였다. 해석 결과의 건전성 검증을 위하여 보일러 출구, 즉 절탄기 후단에서의 가스 온도, O$_2$, NO, CO 농도를 발전소의 실제 측정 결과와 비교하였다. 실제 발전소의 운전조건을 기준으로 보일러내의 가스온도, 속도 분포를 해석하였으며 주요 가스농도인 O$_2$, CO, CO$_2$, NO의 분포와 char 입자 궤적을 구하였다. 본 연구를 통하여 최종과열기 전단에서의 가스 온도가 불균일하게 분포함을 알 수 있었으며, 이는 보일러 상부 연소로에서의 잔류 선회유동의 결과인 것으로 파악되었다. 불균일한 가스온도 분포에 대한 해석결과는 접선연소식 미분탄 보일러에서 자주 발생하는 튜브 파손을 방지하는데 있어 유용한 자료로 활용될 수 있을 것이다.

운전기록 모니터링에 의한 발전보일러용 고압 급수가열기 내부 튜브의 파손예측 (Prediction of Internal Tube Bundle Failure in High Pressure Feedwater Heater for a Power Generation Boiler by the Operating Record Monitoring)

  • 김경섭;유호선
    • 플랜트 저널
    • /
    • 제15권2호
    • /
    • pp.56-61
    • /
    • 2019
  • 본 연구에서는 500 MW급 초임계압 석탄 화력발전소의 발전보일러용 고압 급수가열기에서 발생한 내부 튜브의 파손 사례 분석을 통해 운전 기록 모니터링에 의한 발전보일러용 고압 급수가열기 내부 튜브의 파손 예측 방안을 모색하고자 하였다. 이 연구를 통해 고압 급수가열기 내부 튜브 파손 시 쉘 측 수위 조절 밸브 개도와 보일러 급수펌프 흡입 유량의 변화로 내부 튜브 파손을 진단할 수 있는 예측 모형을 제안하였고, 제안된 예측 모형은 급수 계통의 불균형이 일어난 추가 사례를 통해 실증하였다. 이에 따라 본 연구와 유사한 특성의 발전보일러용 고압 급수가열기의 경우에도 쉘 측 수위 조절 밸브 개도와 보일러 급수펌프의 흡입 유량의 정상 운전 상태 값 대비 현재 운전 값 비교는 고압 급수가열기 내부 튜브의 파손에 대한 유력한 예측 진단 방안이 될 수 있다고 판단된다.

발전용 코너 보일러의 순산소 및 공기연소 화로해석 (Numerical studies of the oxygen and air combustion performance in a Corner-type coal fired boiler)

  • 이인철;장석원
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.198.2-198.2
    • /
    • 2010
  • Three dimensional numerical analysis of the oxygen and air were performed to investigate the combustion characteristics in a Corner-type pulverized coal boiler. With the actual operation data of the power plant, the distribution of velocity, gas temperature, $O^2$, $CO_2$, $H_2O$, $N_2$ as well as the particle tracking in the boiler were investigated. The predicted values at the outlet of furnace for the gas temperature and major species concentrations gave a good agreement with the designed values. The present analysis on combustion characteristics in a boiler would provide the useful information for the stable boiler operation and in trouble shooting boiler problem.

  • PDF

90kW급 우드칩 온수 보일러 특성 및 성능 시험 (Measurement of Efficiency and Flue Gas Concentration of 90 kW Woodchip Boiler)

  • 강새별;김종진;최규성;이웅진
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.194-197
    • /
    • 2008
  • We measured the efficiency and flue gas concentration of a 90kW woodchip boiler which is for heating water of lodging. At nominal operating condition, the fuel, woodchip is fed into the boiler at a rate of 22.6 kg/h. In order to determine the efficiency of the boiler, we measured the water flow rate, woodchip flow rate, heating value and water content of woodchip, temperature of inlet and outlet of heating water. The results of test show that the power output of the woodchip boiler is 90.0 kW(77,400 kcal/h) and the thermal efficiency of the boiler is 88.5%. By using a gas analyser, flue gas concentrations are measured. The results show that O2 in the flue gas is 10.2%, CO concentration is 393 ppm and NOx concentration is 74 ppm.

  • PDF

유동층보일러 수냉벽튜브 결함평가를 위한 원격자장 스캐너 시뮬레이션에 관한 연구 (Simulation of Remote Field Scanner for Defect Evaluation of Water Wall Tube Within the Fluidized Bed Boiler)

  • 길두송;정계조;서정석;김학준;권찬울
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권2호
    • /
    • pp.145-150
    • /
    • 2020
  • 유동층보일러를 구성하는 요소 중 하나인 수냉벽튜브는 외부의 고온 연소 가스를 이용해 물을 증기로 가열하는 튜브군의 하나로써, 보일러를 이용한 전력생산에 중요한 역할을 담당하지만, 고온 가스 및 유동매체로 인해 마모 및 부식이 심하게 일어나면 누수가 발생하게 되고, 누수로 인한 2차 피해도 발생될 뿐만 아니라, 발전 효율이 현저히 떨어지게 되어 수냉벽튜브의 유지보수는 매우 중요하다. 본 연구에서는 원격장 기반의 발신자(Exciter) 센서 설계, 원격장 와전류 시스템 구성, 수냉벽튜브 외벽 결함평가를 목적으로 하였으며, 이를 위한 발신자 형상의 센서 설계를 시작으로, 수냉벽튜브의 크기, 재질, 주파수, Lift-Off (센서와 수냉벽튜브 사이의 거리) 등 여러 가지 요인에 따른 시험을 진행하여 그에 따른 최적의 발신자 센서를 설계하였다.

발전용 보일러 시스템의 이상허용 및 과도상태의 유연한 제어에 관한 연구 (A Study on the Fault-Tolerant and Bumpless Switching Control for Boiler Systems in the Power Plant)

  • 권오규;이영삼
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1037-1040
    • /
    • 1998
  • In this research a fault-tolerant and bumpless switching control is proposed for boiler systems used in the power plants. Firstly, three operating points are selected to control the nonlinear boiler through the full operational range, and the $H_{\infty}$ loop shaping controller and the model-based predictive controller(MBPC) are designed. To prevent the windup and bump problems which are caused by the actuator saturation and the controller switching, an anti-windup and bumpless transfer technique is adopted to the $H_{\infty}$ loop shaping controller. Also the constrained gain-scheduling technique is applied to MBPC to achieve the same objective. Secondly, the fault-tolerant control technique is proposed to continue the control action without stopping the boiler operation even in case of some faults. Through various simulation studies, the performances of the proposed control techniques are demonstrated.

  • PDF

A Case Study of Desulphurization by Limestone Adsorbent in an Industrial CFBC Boiler

  • Park, Young-Goo;Kim, Seung-Ho;Jo, Young-Min
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제21권E2호
    • /
    • pp.67-74
    • /
    • 2005
  • Domestic anthracite contains a large amount of fine particles, which causes to fire the back side of the boiler and to form the clinker deteriorating the combustion efficiency. At this time, the fine limestone adsorbents for a desulphurization agent may be used to facilitate an aggravation of the boiler, so that fine mode of limestone (<0.1mm) has been used no more than $25\%$ in local power stations of Korea. The present test carried out with an in-situ boiler, however, showed that higher content $(up\;to\;50\%)$ of fine limestone particles did not entail any mal-function. In addition, the desulphurization was found to be as good as the old mode of limestone adsorbents.