• Title/Summary/Keyword: Power Test Bench

Search Result 94, Processing Time 0.031 seconds

FPGA-Based Low-Power and Low-Cost Portable Beamformer Design (FPGA 기반 저전력 및 저비용 휴대용 빔포머 설계)

  • Jeong, GabJoong;Park, CheolYoung
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.24 no.1
    • /
    • pp.31-38
    • /
    • 2019
  • In this paper, we develop a beamforming front end platform with pipeline circuit configuration method that can apply various clinical diagnostic applications of ultrasound image technology. Hardware design targets compression applications as well as scalable applications where power, integration levels and replication possibilities are important. Firmware design was implemented to achieve optimal FPGA parallel processing level by constructing new IP and system-oriented design environment to accelerate design productivity with maximum productivity improvement using Vivado HLS tool, which is a next generation high level synthesis tool. Former supports the high-speed management function of scan data that can create an image area arbitrarily and can be appropriately corrected and supplemented when reconfiguring or changing system specifications in the future.

Single Phase Inverter High Frequency Circuit Modeling and Verification for Differential Mode Noise Analysis (차동 노이즈 분석을 위한 단상 인버터 고주파 회로 모델링 및 검증)

  • Shin, Ju-Hyun;Seng, Chhaya;Kim, Woo-Jung;Cha, Hanju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.3
    • /
    • pp.176-182
    • /
    • 2021
  • This research proposes a high-frequency circuit that can accurately predict the differential mode noise of single-phase inverters at the circuit design stage. Proposed single-phase inverter high frequency circuit in the work is a form in which harmonic impedance components are added to the basic single-phase inverter circuit configuration. For accurate noise prediction, parasitic components present in each part of the differential noise path were extracted. Impedance was extracted using a network analyzer and Q3D in the measurement range of 150 kHz to 30 MHz. A high-frequency circuit model was completed by applying the measured values. Simulations and experiments were conducted to confirm the validity of the high-frequency circuit. As a result, we were able to predict the resonance point of the differential mode voltage extracted as an experimental value with a high-frequency circuit model within an approximately 10% error. Through this outcome, we could verify that differential mode noise can be accurately predicted using the proposed model of the high-frequency circuit without a separate test bench for noise measurement.

Research on diagnosis method of centrifugal pump rotor faults based on IPSO-VMD and RVM

  • Liang Dong ;Zeyu Chen;Runan Hua;Siyuan Hu ;Chuanhan Fan ;xingxin Xiao
    • Nuclear Engineering and Technology
    • /
    • v.55 no.3
    • /
    • pp.827-838
    • /
    • 2023
  • Centrifugal pump is a key part of nuclear power plant systems, and its health status is critical to the safety and reliability of nuclear power plants. Therefore, fault diagnosis is required for centrifugal pump. Traditional fault diagnosis methods have difficulty extracting fault features from nonlinear and non-stationary signals, resulting in low diagnostic accuracy. In this paper, a new fault diagnosis method is proposed based on the improved particle swarm optimization (IPSO) algorithm-based variational modal decomposition (VMD) and relevance vector machine (RVM). Firstly, a simulation test bench for rotor faults is built, in which vibration displacement signals of the rotor are also collected by eddy current sensors. Then, the improved particle swarm algorithm is used to optimize the VMD to achieve adaptive decomposition of vibration displacement signals. Meanwhile, a screening criterion based on the minimum Kullback-Leibler (K-L) divergence value is established to extract the primary intrinsic modal function (IMF) component. Eventually, the factors are obtained from the primary IMF component to form a fault feature vector, and fault patterns are recognized using the RVM model. The results show that the extraction of the fault information and fault diagnosis classification have been improved, and the average accuracy could reach 97.87%.

Preliminary Experiments for the Remediation of Trichloroethene-Contaminated Groundwater Using Direct-Current and Zero-Valent Iron (0가 철과 직류전원을 이용한 TCE 오염 지하수의 정화기법 예비조사)

  • Moon, Ji-Won;Moon, Hi-Soo;Roh, Yul;Lee, Suk-Young;Song, Yun-Goo
    • Economic and Environmental Geology
    • /
    • v.34 no.3
    • /
    • pp.307-313
    • /
    • 2001
  • Reactive medium including zero-valent metals such as zero-valent iron ($Fe^0$) degrades chlorinated solvents as a contaminant plume flows through the treatment medium. Although the Feo based reactive barrier has been demonstnlted to be a cost effective for trichloroethenc (TCE)-contaminaled plume remediation, current approach is limited by low process eftlciency and uncertain, effective life of the medium. The objective of this study is to develop an enhanced treatment method of TeE-contaminated groundwater using Feo and direct current. The bench-scale test using flow-through $Fe^0$ reactor column confirmed that the application of direct current with $Fe^0$ is highly effective in enhancing the rate of TeE dechlorination. The dechlorination mechanism appears to be reductive, with the electrons supplied by the iron oxidation and external power supply serving as the additional source of electrons.

  • PDF

Development of New Techniques of Electrostatic Separation for Using of Clean Coal (청정석탄(淸淨石炭) 이용(利用)을 위한 정전선별(靜電選別) 기술개발(技術開發))

  • Baek, Sang-Ho;Jeon, Ho-Seok;Han, Oh-Hyung
    • Resources Recycling
    • /
    • v.14 no.5 s.67
    • /
    • pp.54-61
    • /
    • 2005
  • In 2006, the coal usage that is used as energy source of power plant will meet 16,000 MW which is 30% of the whole energy usage. A Coal deposits among the fossil fuels is very plentiful in natural resources and has high economical efficiency but application technique is very inconvenient. Also when burned for utilization, it generate various toxic and untoxic air pollution materials; fly ash, bottom ash, sulfurous acid gas etc. In this study, we could establish a preparation of clean coal by triboelectrostatic separation. In this study, we made a bench-scale's triboelectrostatic separation equipment using electrostatic technology, and got an optimum conditions of various factors for increasing recovery rate and purification in separation. A test result, we got a clean coal that recovery rate is 68.10%, rejection rate of ash and sulfur content is 31.23% and 28.33%.

Performance Characteristics of CNG Vehicle at Various Compression Ratios (압축비 변경에 따른 CNG차량의 성능특성 연구)

  • 김봉석;이영재;고창조
    • Journal of Energy Engineering
    • /
    • v.5 no.1
    • /
    • pp.42-49
    • /
    • 1996
  • Natural gas is one of the promising alternative fuels for automotive vehicles, because it has lower exhaust emissions and better fuel economy characteristics than those of gasoline, and can be used in conventional gasoline engines without major modifications. In the present study, a conventional gasoline engine was modified to a CNG engine, which can be operated with CNG only, and an engine bench test was performed to calibrate the operating parameters of the engine such as air fuel ratio, spark advance, etc. at various operating conditions. The modified CNG engine, then, was installed on a commercial gasoline vehicle and a vehicle driving test on chassis dynamometer was performed to examine the fuel economy and exhaust emission characteristics. As a result, the prototype CNG vehicle showed lower exhaust emissions and better fuel economy characteristics, but slightly reduced brake horse power, compared to the gasoline vehicle.

  • PDF

A Study on Flow Rate Characteristic and Dynamic Performance on Diaphragm Solenoid Valve (다이어프램형 밸브의 유량특성과 동적성능에 관한 연구)

  • Jeong, C.S.;Yang, S.Y.
    • Journal of Drive and Control
    • /
    • v.10 no.3
    • /
    • pp.27-33
    • /
    • 2013
  • Solenoid valve has used in various industrial field extensively. A solenoid valve has different size, shape and method of operation accordantly to industrial field. Many researchers study on kinds of solenoid valve such as flow rate, dynamic, magnetic field, valve shape and operating method. But the flow rate characteristic and dynamic response time performance on the diaphragm valve are not studied. This paper describes the flow rate characteristic and dynamic response time performance on the diaphragm valve. At first, the diaphragm valve is simulated in AMESim simulation tool. AMESim model found that an effect of valve performance depends on parameter. The parameter is the diaphragm orifice area. And the performance test bench confirms the effect in this parameter. Finally, it finds out the flow rate characteristic and dynamic response time performance on the diaphragm valve.

Vibration Attenuation in Helicopters using an Active Trailing-edge Flap Blade

  • Natarajan, Balakumaran;Eun, WonJong;Shin, SangJoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.347-352
    • /
    • 2013
  • Seoul National University Flap (SNUF) blade is a small-scaled rotor blade incorporating a small trailing-edge flap control surface driven by piezoelectric actuators at higher harmonics for vibration attenuation. Initially, the blade was designed using two-dimensional cross-section analysis and a geometrically exact one-dimensional beam analysis, and material configuration was finalized. Flap deflection angle of ${\pm}45^{\circ}$ was established as the criterion for better vibration reduction performance based on an earlier simulation. Flap linkage mechanism design is carried out and static bench tests are conducted to verify the flap actuation mechanism performance. Different versions of test beds are developed and tested with the flap and chosen APA 200M piezoelectric actuators. Through significant improvements, a maximum deflection of ${\pm}3.7^{\circ}$ was achieved. High frequency experiments are conducted to evaluate the performance and transfer function of the test bed is determined experimentally. As the static tests are almost completed, rotor power required for testing the blade in whirl tower (centrifugal environment) is calculated and further preparations are under way.

  • PDF

Water-Side Oxide Layer Thickness Measurement of the Irradiated PWR Fuel Rod by NDT Method

  • Park, Kwang-June;Park, Yoon-Kyu;Kim, Eun-Ka
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05a
    • /
    • pp.680-686
    • /
    • 1995
  • It has been known that water-side corrosion of fuel rods in nuclear reactor is accompanied with the loss of metallic wall thickness and pickup of hydrogen. This corrosion is one of the important limiting factors ill the operating life of fuel rods. In connection with the fuel cladding corrosion, a device to measure the water-side oxide layer thickness by means of the eddy-current method without destructing the fuel rod was developed by KAERI. The device was installed on the multi-function testing bench in the nondestructive test hot-cell and its calibration was carried out successfully for the standard rod attached with plastic thin films whose thicknesses are predetermined. It shows good precision within about 10% error. And a PWR fuel rod, one of the J-44 assembly discharged from Kori nuclear power plant Unit-2, has been selected for oxide layer thickness measurements. With the result of data analysis, it appeared that the oxide layer thicknesses of Zircaloy cladding vary with the length of the fuel rod, and their thicknesses were compared with those of the destructive test results to confirm the real thicknesses.

  • PDF

Gas Pulsation Analysis in a T-Shaped Suction Passage of a CO2 Twin Rotary Compressor (CO2 트윈 로타리 압축기의 흡입관로에서의 가스맥동 해석)

  • Kim, Woo-Young;Ahn, Jong-Min;Kim, Hyun-Jin;Cho, Sung-Oug
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.8
    • /
    • pp.549-555
    • /
    • 2011
  • For a $CO_2$ one-stage twin rotary compressor, a T-shaped suction port was used to effectively supply the suction gas stream into two individual suction chambers of the twin cylinders. Suction gas pulsations were observed in the pressure sensor signals and these were simulated by using the acoustic modeling of Helmholz resonators in parallel. The module of acoustic modeling was combined to a computer simulation program for the compressor performance. Validation of the simulation program has been carried out for a bench model compressor in a compressor calorimeter. Cooling capacity and the compressor input power were reasonably well compared between the simulation and the calorimeter test. Particularly, good agreement on P-V diagram between the simulation and the test was obtained.