• 제목/요약/키워드: Power System Control and Operation

검색결과 1,997건 처리시간 0.031초

Operation Analysis of a Communication-Based DC Micro-Grid Using a Hardware Simulator

  • Lee, Ji-Heon;Kim, Hyun-Jun;Han, Byung-Moon
    • Journal of Power Electronics
    • /
    • 제13권2호
    • /
    • pp.313-321
    • /
    • 2013
  • This paper describes the operation analysis results of a communication-based DC micro-grid using a hardware simulator developed in the lab. The developed hardware simulator is composed of distributed generation devices such as wind power, photovoltaic power and fuel cells, and energy storage devices such as super-capacitors and batteries. Whole system monitoring and control was implemented using a personal computer. The power management scheme was implemented in a main controller based on a TMS320F28335 chip. The main controller is connected with the local controller in each of the distributed generator and energy storage devices through the communication link based on a CAN or an IEC61850. The operation analysis results using the developed hardware simulator confirm the ability of the DC micro-grid to supply the electric power to end users.

인공위성용 총방전 시스템의 해석 (Analysis of the battery charging and discharging system for spacecrafts)

  • 김영태;김희진
    • 전자공학회논문지B
    • /
    • 제32B권6호
    • /
    • pp.932-942
    • /
    • 1995
  • A spacecraft power system can be divided into two types : DET system(Direct Energy Transfer system) and PPT system(Peak Power Tracking system). In a DET system employing the regulated bus voltage control method, the battery charger and discharger are widely used for the bus voltage regulation. The battery charger has two different modes of operation. One is the bus voltage regulation mode and the other is the charge current regulation mode. The battery discharger is employed to provide the power when the spacecraft is in the earth's shadow or the sun is eclipsed. The operating mode, charging or discharging, is selected by a power control circuit. In this paper, small-signal dynamic characteristics of battery charging and discharging system are analyzed to facilitate design of control loop for optimum performance. Control loop designs in various operating modes are discussed. Anaylses are verified through experiments.

  • PDF

고분자 전해질 연료전지와 슈퍼캐패시터 하이브리드 시스템의 운전 전략에 관한 연구 (Study of Operation Strategy for Hybrid PEM Fuel Cell and Supercapacitor)

  • 박광진;지현진;배중면
    • 대한기계학회논문집B
    • /
    • 제30권8호
    • /
    • pp.756-763
    • /
    • 2006
  • PEMFC has several technical problems such as water management, long term stability and performance degradation as. PEMFC has been studied not only to solve water management, but also to generate power in stable manner to system by using a hybrid system with auxiliary energy storage device. The purpose of this study is to couple PEMFC with supercapacitor to make a hybrid system and to design and test control strategies for stable power generation in case of changing output power. The polarization curve and dynamic behaviors while changing power were investigated to find out characteristics of PEMFC stack. A DC/DC converter was fabricated in order to increase fuel cell and supercapacitor voltage and to charge supercapacitor. We found that the operation strategy 2 was recommended to the system because of solving water management problem and increasing the dynamic behavior.

배터리 충전을 위한 소형풍력 발전 시스템의 병렬 운전방안에 관한 연구 (A Study on the Parallel Operation Strategy of Small Wind Turbine System for Battery Charging)

  • 손영득;구현근;김장목
    • 전력전자학회논문지
    • /
    • 제19권6호
    • /
    • pp.549-556
    • /
    • 2014
  • This study proposes a parallel operation strategy for small wind turbine systems. A small wind turbine system consists of blade, permanent magnet synchronous generator, three-phase diode rectifier, DC/DC buck converter, and the battery load. This configuration has reliability, simple control algorithm, high efficiency, and low cost. In spite of these advantages, the system stops when unexpected failures occur. Possible failures can be divided into mechanical and electrical parts. The proposed strategy focuses on the failure of electrical parts, which is verified by numerical analysis through equivalent circuit and acquired general formula of small wind power generation systems. Simulation and experimental results prove its efficiency and usefulness.

여름철 공조시스템의 최적 운전 제어 방식 (Optimal air-conditioning system operating control strategies in summer)

  • 허정호
    • 설비공학논문집
    • /
    • 제9권3호
    • /
    • pp.410-425
    • /
    • 1997
  • Buildings are mostly under part load conditions causing an inefficient system operation in terms of energy consumption. It is critical to operate building air-conditioning system with a scientific or optimal manner which minimizes energy consumption and maintains thermal comfort by matching building sensible and latent loads. Little research has been performed in developing general methodologies for the optimal operation of air-conditioning system. Based on this research motivation, system simulation program was developed by adopting various equipment operating strategies which are energy efficient especially for humidity control in summer. A numerical optimization technique was utilized to search optimal solution for multi-independent variables and then linked to the developed system simulation model within a mam program. The main goal of the study is to provide a systematic framework and guideline for the optimal operation of air-conditioning system focusing on air-side. For given cooling loads and ambient outdoor conditions the optimal operating strategies of a commercial building are determined by minimizing a constrained objective function by a nonlinear programming technique. Desired space setpoint conditions were found through evaluating the trade-offs between comfort and system power consumption. The results show that supply airflow rate and compressor fraction play main roles in the optimization process. It was found that variable setpoint optimization technique could produce lower indoor humidity level demanding less power consumption which will be benefits for building applications of humidity problem.

  • PDF

수력발전소 설비 신뢰성 분석을 위한 FMEA (FMEA for Facility Reliability Analysis of A Hydro-power Plant)

  • 권창섭;전태보
    • 산업기술연구
    • /
    • 제26권B호
    • /
    • pp.135-144
    • /
    • 2006
  • The significance of hydro-power plant is increasing in its public roles such as flood control and water supply as well as electric power production. Even if high level of reliability in facility operation is required, no specific reliability research has been made. This specifically stems from the lack of technology and research investments. The eventual goal of this study is to secure a methodology for reliability analysis of hydro-power plant so that an appropriate decision for operation and investment can be made. Specific effort was put to develop a reliability model for water supply system within hydro-power plant. For this study, we briefly examined the overview of the hydro-power plant including the electric power generation facility system. We then discussed the facility reliability analysis methodology for hydro-power plant. Based on rigorous examination of the water supply system and components roles, we drew major failure modes for each component and examined their effects.

  • PDF

Kalman-Filter Based Static Load Modeling of Real Power System Using K-EMS Data

  • Lee, Soo-Hyoung;Son, Seo-Eun;Lee, Sung-Moo;Cho, Jong-Man;Song, Kyung-Bin;Park, Jung-Wook
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권3호
    • /
    • pp.304-311
    • /
    • 2012
  • So far, the importance for an accurate load model has been constantly raised and its necessity would be further more emphasized. Currently used load model for analysis of power system in Korea was developed 10 years ago, which is aggregated by applying the statistically estimated load compositions to load models based on individual appliances. As modern appliances have diversified and rapidly changed, the existing load model is no longer compatible with current loads in the Korean power system. Therefore, a measurement based load model is more suitable for modern power system analysis because it can accurately include the load characteristics by directly measuring target load. This paper proposes a ZIP model employing a Kalman-filter as the estimation algorithm for the model parameters. The Kamlan-filter based parameter identification offers an advantage of fast parameter determination by removing iterative calculation. To verify the proposed load model, the four-second-interval real data from the Korea Energy Management System (K-EMS) is used.

New Soft-Switching Current Source Inverter for Photovoltaic Power System

  • Han Byung-Moon;Kim Hee-Joong;Baek Seung-Taek
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.644-649
    • /
    • 2001
  • This paper proposes a soft-switching current -source inverter for photovoltaic power system, which has an H-type switched-capacitor module composed of two semiconductor switches, two diodes, and an L-C resonant circuit. The operation of proposed system was analyzed by a theoretical approach with equivalent circuits and verified by computer simulations with SPICE and experimental works with a hardware prototype. The proposed system could be effectively applied for the power converter of photovoltaic power system interconnected with the power system.

  • PDF

계통 연계 태양광 발전 시스템을 위한 Power Conditioning 시스템 (Power Conditioning System for Grid-connective PV Power Systems)

  • 이성룡;고성훈
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.38-41
    • /
    • 2002
  • Increasing of the use nonlinear power electronics equipments, power conditioning systems have been researched and developed for many years to compensate the harmonic disturbances and the reactive power. The main function of power conditioning systems is to reduce harmonic distortions, since extensive surveys quantify the problems associated with electric networks haying non-linear loads. The main function of power conditioner compensates the current instead of the voltage. Therefore the inverter used in power conditioner ismostley current controlled type. In this paper, the proposed current control algorithm is analyzed and discussed about how to design the controller which can apply power conditioning operation for grid-connective PV power system. And also proposed control system. To verify the proposed current control algorithm, a comprehensive evaluation with theoretical analysis, simulation results is presented.

  • PDF

샤프트 발전기와 디젤 발전기의 병렬운전 제어시스템 설계에 대한 연구 (The study of Shaft Generators and Diesel Generators for parallel operation of control system)

  • 황보영;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2012년도 춘계학술대회
    • /
    • pp.318-321
    • /
    • 2012
  • 본 논문에서는 샤프트 발전기와 디젤 발전기를 같이 사용하는 하이브리드 발전시스템의 구성과 발전기와 전력모선(Bus Bar)의 연결, 발전기 운영방식, 샤프트 발전기와 디젤 발전기의 병렬운전 과정을 통해 샤프트 발전기와 디젤 발전기의 병렬운전 제어 시스템의 설계 시 고려사항을 제시한다.

  • PDF