• 제목/요약/키워드: Power System Control and Operation

검색결과 1,995건 처리시간 0.031초

뉴로-퍼지 제어기를 이용한 전력시스템의 발전량 증가율 제한에 관한 연구 (A study on Generation rate Constraints of Power System using Neuro-Fuzzy Controller)

  • 김상효;이창우;주석민;정동일;정형환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.301-303
    • /
    • 2002
  • The load frequency control of power system is one of important subjects in view of system operation and control. To converge within allowance load variation value the frequency and tie-line power flow deviation of each areas, we should regulate the active power output of power plant for regulation in system Applying the NFC(Neuro-Fuzzy Controller) to the model of load frequency control of 2-area power system, we prove that the control is superior to the conventional control technique through computer simulation. For verification of robustness, when we consider generator-rate constraint similar to nonlinearities of power system.

  • PDF

PW206C 터보축 엔진의 수동운용범위 분석 (Operation limits analysis of PW206C turboshaft engine In manual mode)

  • 이창호
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제29회 추계학술대회논문집
    • /
    • pp.339-342
    • /
    • 2007
  • 스마트무인기의 추진동력계통은 터보프롭 항공기와 유사한 피치 가버닝 개념으로 조종사가 엔진동력을 직접 입력하고 제어기는 프로펠러의 RPM을 일정하게 유지하는 방식을 사용한다. PW206C 엔진은 회전익 항공기에 맞게 개발된 전자식 엔진제어기(Electronic Engine Control)를 갖춘 터보축엔진으로 스마트무인기에서 요구되는 엔진제어개념과는 맞지 않는다. 따라서 기존 EEC의 엔진상태 모니터링 기능은 사용하되 엔진 출력은 수동방식으로서 전기식 작동기를 엔진의 Power Lever Arm(PLA)에 연결하여 조절한다. 본 논문에서는 엔진성능계산프로그램을 사용하여 비행고도 및 속도변화에 대한 엔진성능을 계산하여 각 비행조건에서의 PLA 작동범위를 예측하였다.

  • PDF

전력계통의 고장점 판별에 대한 전문가 시스템 연구 (A Study on The Expert System for Finding Fault Section of Power System)

  • 강동구;김정하;박규홍;정재길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.637-639
    • /
    • 1995
  • Since power systems tend to be more large and complex, expert system substituted for the decision-making achieved by the power system operation expert is required. So far, expert system has been used for fault diagonosis and voltage-reactive power control and so on. In the expert system developed using 'C' language, the faulted element is estimated using the AND operation of lists which are acquired from the information on operated relays. It is also considered to identify the misoperation of protective devices using CF(Certainty Factor), and operation failure of those using the data base of parameter group list. The developed expert system is applied to a 6-bus sample system and through the case studies. It is shown that the expert system is very useful.

  • PDF

A Takagi-Sugeno fuzzy power-distribution method for a prototypical advanced reactor considering pump degradation

  • Yuan, Yue;Coble, Jamie
    • Nuclear Engineering and Technology
    • /
    • 제49권5호
    • /
    • pp.905-913
    • /
    • 2017
  • Advanced reactor designs often feature longer operating cycles between refueling and new concepts of operation beyond traditional baseload electricity production. Owing to this increased complexity, traditional proportional-integral control may not be sufficient across all potential operating regimes. The prototypical advanced reactor (PAR) design features two independent reactor modules, each connected to a single dedicated steam generator that feeds a common balance of plant for electricity generation and process heat applications. In the current research, the PAR is expected to operate in a load-following manner to produce electricity to meet grid demand over a 24-hour period. Over the operational lifetime of the PAR system, primary and intermediate sodium pumps are expected to degrade in performance. The independent operation of the two reactor modules in the PAR may allow the system to continue operating under degraded pump performance by shifting the power production between reactor modules in order to meet overall load demands. This paper proposes a Takagi-Sugeno (T-S) fuzzy logic-based power distribution system. Two T-S fuzzy power distribution controllers have been designed and tested. Simulation shows that the devised T-S fuzzy controllers provide improved performance over traditional controls during daily load-following operation under different levels of pump degradation.

엔진발전기와 연계된 BESS의 무순단 모드 전환 기법 (Seamless Transfer Method of BESS Connected by Engine Generator)

  • 신은석;김현준;김교민;유승영;한병문
    • 전기학회논문지
    • /
    • 제64권12호
    • /
    • pp.1709-1717
    • /
    • 2015
  • In remote islands PV (Photo Voltaic) panel with BESS (Battery Energy Storage System) supplies electric power to the customers in parallel operation with EG (Engine Generator) to save fuel consumption and to mitigate environmental load. BESS operates in voltage control mode when it supplies power to the load alone, while it operates in current control mode when it supplies power to the load in parallel with EG. This paper proposes a smooth mode change scheme from current control to voltage control of BESS by adding proper initial value to the integral part of voltage control, and a smooth mode change scheme from voltage control to current control by tracking the EG output voltage to the BESS output voltage using PLL (Phase-Locked Loop). The feasibility of proposed schemes was verified through computer simulations with PSCAD/EMTDC, and the feasibility of actual hardware system was verified by experiments with scaled prototype. It was confirmed that the proposed schemes offer a seamless operation in the stand-alone power system in remote islands.

스마트 홈에서 Zigbee 기반의 대기전력 제어 연구 (A Study of Standby Power Control Based on Zigbee in Smart Home)

  • 이성준;김도현
    • 한국멀티미디어학회논문지
    • /
    • 제17권7호
    • /
    • pp.879-885
    • /
    • 2014
  • This paper designs and implements the 2 plug type standby power control outlet based on IEEE 802.15.4 using Zigbee and IPv6 network in order to reduce the standby power to the user. The standby power control system is consisted of direct power and standby power plug. Also this system can communicate bidirectionally in wireless because built-in wireless communication modules. One gateway is linked with many standby power control outlet in wireless. Each standby power control outlet executes the operation needed in power control independently. Also each standby power control outlet has its own power can be detected in real time independently of the power can be controlled.

고효율, 고전력밀도 아답터를 위한 도통밴드 제어 AC-DC 벅 컨버터 (A Conduction Band Control AC-DC Buck Converter for a High Efficiency and High Power Density Adapter)

  • 문상철;정봉근;구관본
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.38-39
    • /
    • 2017
  • This paper proposes a new control method for an AC-DC Buck converter which is utilized as a front-end converter of a 2-stage high power density adapter. In the conventional adapter applications, 2-stage configuration shows higher power transfer efficiency and higher power density than those of the single stage flyback converter. In the 2-stage AC-DC converter, the boost converter is widely used as a front-end converter. However, an efficiency variation between high AC line and low AC line is large. On the other hand, the proposed conduction band control method for a buck front-end converter has an advantage of small efficiency variation. In the proposed control method, switching operation is determined by a band control voltage which represents output load condition, and an AC line voltage. If the output load increasesin low AC line, the switching operation range is expanded in half of line cycle. On the contrary, in light load and high line condition, the switching operation is narrowed. Thus, the proposed control method reduces switching loss under high AC line and light load condition. A 60W prototype which is configured the buck and LLC converter with the proposed control method is experimented on to verify the validity of the proposed system. The prototype shows 92.16% of AC-DC overall efficiency and 20.19 W/in 3 of power density.

  • PDF

A Study on a Single-Phase Module UPS using a Three-Arm Converter/Inverter

  • Choi Y.K.;Ko T.G.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.987-993
    • /
    • 2003
  • The module UPS can flexibly implement expansion of power system capacities. Furthermore, it can be used to build up the parallel redundant system to improve the reliability of power system operation. To realize the module UPS, load sharing without interconnection among parallel connecting modules as well as a small scale and lightweight topology is necessary. In this paper, the three-arm converter/inverter is compared with the general full-bridge and half-bridge topology from a practical point of view and chosen as the module UPS topology. The switching control approaches based on a pulse width modulation of the converter and inverter of the system are presented independently The frequency and voltage droop method is applied to parallel operation control to achieve load sharing. Two prototype 3kVA modules are designed and implemented to confirm the effectiveness of the proposed approaches. Experimental results show that the three-arm UPS system has a high power factor, a low distortion of output voltage and input current, and good load sharing characteristic.

  • PDF

The Implementation of Storage Type Power Flow Controller using Battery Storage

  • Leung, K.K.;Sutanto, D.
    • Journal of Power Electronics
    • /
    • 제1권2호
    • /
    • pp.99-106
    • /
    • 2001
  • This paper describes the implementation of a Storage Power Flow Controller (SPFC) connected to the grid which can provide concomitant benefits associated with a Unified Power Flow Controller while at the same time providing several other very important benefits to power system operation such as, load leveling dynamic voltage stability inprovement, harmonic compensation and power factor correction. This Storage power Flow Controller (SPFC) was implemented using real time signal processors, three-phase inverter(s) and battery bank which can provide improved power system operation and control, added system security and reduced power system losses.

  • PDF

Development of a low energy ion irradiation system for erosion test of first mirror in fusion devices

  • Kihyun Lee;YoungHwa An;Bongki Jung;Boseong Kim;Yoo kwan Kim
    • Nuclear Engineering and Technology
    • /
    • 제56권1호
    • /
    • pp.70-77
    • /
    • 2024
  • A low energy ion irradiation system based on the deuterium arc ion source with a high perveance of 1 µP for a single extraction aperture has been successfully developed for the investigation of ion irradiation on plasma-facing components including the first mirror of plasma optical diagnostics system. Under the optimum operating condition for mirror testing, the ion source has a beam energy of 200 eV and a current density of 3.7 mA/cm2. The ion source comprises a magnetic cusp-type plasma source, an extraction system, a target system with a Faraday cup, and a power supply control system to ensure stable long time operation. Operation parameters of plasma source such as pressure, filament current, and arc power with D2 discharge gas were optimized for beam extraction by measuring plasma parameters with a Langmuir probe. The diode electrode extraction system was designed by IGUN simulation to optimize for 1 µP perveance. It was successfully demonstrated that the ion beam current of ~4 mA can be extracted through the 10 mm aperture from the developed ion source. The target system with the Faraday cup is also developed to measure the beam current. With the assistance of the power control system, ion beams are extracted while maintaining a consistent arc power for more than 10 min of continuous operation.