• Title/Summary/Keyword: Power Spectral Density Analysis

Search Result 241, Processing Time 0.027 seconds

The Power Spectral Density Characteristics of Lift and Drag Fluctuation of Fin Tube in a Heat Recovery Steam Generator (배열회수 보일러 단일 휜튜브의 양력과 항력 변동에 따른 PSD 특성 연구)

  • Ha, Ji Soo;Lee, Boo Youn
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.2
    • /
    • pp.23-29
    • /
    • 2016
  • Heat exchanger tube array in a heat recovery steam generator is exposed to the hot exhaust gas flow and it could cause the flow induced vibration, which could damage the heat exchanger tube array. It is needed for the structural safe operation of the heat exchanger to establish the characteristics of flow induced vibration in the tube array. The researches for the flow induced vibration of typical heat exchangers have been conducted by using single cicular tube or circular tube array and the nondimensional PSD(Power Spectral Density) function with the Strouhal number, fD/U, had been derived by experimental method. From the present study, the basis for the application of flow induced vibration to the heat recovery steam generator tube array would be prepared. For the previous mentioned purpose, the present CFD analysis introduced a single fin tube and calculated with the unsteady laminar flow over the single fin tube. The characteristics of vortex shedding and lift and drag fluctuation over the fin tube was investigated. The derived nondimensional lift PSD was compared with the results of the previous experimental studies and the characteristics of lift and drag PSD over a single fin tube was established from the present CFD study.

A Study on the Characteristics of Lift Fluctuation Power Spectral Density on a Fin Tube in the Heat Recovery Steam Generator (배열회수 보일러 단일 휜튜브의 양력 변동 PSD 특성 연구)

  • Ha, Ji Soo;Lee, Boo Youn;Shim, Sung Hun
    • Journal of Energy Engineering
    • /
    • v.24 no.4
    • /
    • pp.211-216
    • /
    • 2015
  • Heat exchanger tube array in a heat recovery steam generator is exposed to the hot exhaust gas flow and it could cause the flow induced vibration, which could damage the heat exchanger tube array. It is needed for the structural safe operation of the heat exchanger to establish the characteristics of flow induced vibration in the tube array. The researches for the flow induced vibration of typical heat exchangers have been conducted by using single cicular tube or circular tube array and the nondimensional PSD(Power Spectral Density) function with the Strouhal number, fD/U, had been derived by experimental method. From the present study, the basis for the application of flow induced vibration to the heat recovery steam generator tube array would be prepared. For the previous mentioned purpose, the present CFD analysis introduced a single fin tube and calculated with the unsteady laminar flow over the single fin tube. The characteristics of vortex shedding and lift fluctuation over the fin tube was investigated. The derived nondimensional PSD was compared with the results of the previous experimental researches and the characteristics of lift PSD over a single fin tube was established from the present CFD study.

Mathematical Analysis Power Spectrum of M-ary MSK and Detection with Optimum Maximum Likelihood

  • Niu, Zheng;Jiang, Yuzhong;Jia, Shuyang;Huang, Zhi;Zou, Wenliang;Liu, Gang;Li, Yu
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.8
    • /
    • pp.2900-2922
    • /
    • 2021
  • In this paper, the power spectral density(PSD) for Multilevel Minimum Shift Keyed signal with modulation index h = 1/2 (M-ary MSK) are derived using the mathematical method of the Markov Chain model. At first, according to an essential requirement of the phase continuity characteristics of MSK signals, a complete model of the whole process of signal generation is built. Then, the derivations for autocorrelation functions are carried out precisely. After that, we verified the correctness and accuracy of the theoretical derivation by comparing the derived results with numerical simulations using MATLAB. We also divided the spectrum into four components according to the derivation. By analyzing these figures in the graphic, each component determines the characteristics of the spectrum. It is vital for enhanced spectral characteristics. To more visually represent the energy concentration of the main flap and the roll-down speed of the side flap, the specific out-of-band power of M-ary MSK is given. OMLCD(Optimum Maximum Likelihood Coherent Detection) of M-ary MSK is adopted to compare the signal received with prepared in advance in a code element T to go for the best. And M-ary MSK BER(Bit Error Rate) is compared with the same ary PSK (Phase Shift Keying) with M=2,4,6,8. The results show the detection method could improve performance by increasing the length of L(memory inherent) in the phase continuity.

Development of Parameters on Depth of Anesthesia using Power Spectrum Density Analysis during General Anesthesia (전신 마취 중 전력스펙트럼 분석을 이용한 마취심도 파라미터 개발)

  • Baik, Seong-Wan;Ye, Soo-Young;Park, Jun-Mo;Jeon, Gye-Rok
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.6
    • /
    • pp.537-545
    • /
    • 2009
  • In this paper, new parameters were developed to estimate the depth of anesthesia during a general anesthesia using EEG. Power spectral density(PSD) analysis was used for these parameters because EEG became slow wave during anesthesia. The new parameters were DTR, ATR, TDR, ADR, BTR and BDR applied to PSD. These parameters were compared with SEF which is conventionally used at clinic and confirmed clinical value. As the results, DTR, ATR, TDR, ADR among parameters were not useful compared with SEF but BTR and BDR is valuable for clinic. 15 patents, at pre-operation BDR the value is $265.36{\pm}25.29$, at induction the value is $129.23{\pm}34.92$, at operation the value is $154.99{\pm}38.34$, at awaked the value is $283.83{\pm}39.80$ and at post-operation the value is $234.80{\pm}23.46$. Also at pre-operation BTR value is $183.38{\pm}13.59$, at induction the value is $104.09{\pm}25.11$, at operation the value is $115.38{\pm}23.42$, at awaked the value is $190.33{\pm}23.31$ and at post-operation the value is $172.38{\pm}19.08$. Trend of BDR and BTR is similar to change of SEF, so two parameters are useful. to estimate the depth of anesthesia.

EMI reduction of PWM converter By Binary Switching Frequency Modulation (2진 스위칭 주파수 변조에 의한 PWM 컨버터의 EMI 저감)

  • Jin, In-Su;Park, Seok-Ha;Yang, Kyeong-Rok;Kim, Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2650-2652
    • /
    • 1999
  • To satisfy the demand for small size, light weight. high density power supply, the switching frequency of DC/DC converters has been increased. The PWM control of the conventional SMPS have a switching frequency that a level of the conducted noise spectra contribute to switching frequency band. So the electronic equipment is not only affected from that but is restricted to internal regulation like CISPR, FCC, and VDE. In this paper, we analyzed Bi-FM. Bi-FM is two fixed switching frequency with a modulation frequency. So emission spectrum of Bi-FM control signal is spreaded and spectral power level is reduced. In this paper, we analyze the spectral analysis of Bi-FM control signal and the spectral comparison between the PWM control and Bi-FM control. And we confirm that reduced the spectrum power level through simulation using Pspice and experiment.

  • PDF

Frequency Recognition in SSVEP-based BCI systems With a Combination of CCA and PSDA (CCA와 PSDA를 결합한 SSVEP 기반 BCI 시스템의 주파수 인식 기법)

  • Lee, Ju-Yeong;Lee, Yu-Ri;Kim, Hyoung-Nam
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.10
    • /
    • pp.139-147
    • /
    • 2015
  • Steady state visual evoked potential (SSVEP) has been actively studied because of its short training time, relatively higher signal-to-noise ratio, and higher information transfer rate. There are two popular analysis methods for SSVEP signals: power spectral density analysis (PSDA) and canonical correlation analysis (CCA). However, the PSDA is known to be vulnerable to noise due to the use of a single channel. Although conventional CCA is more accurate than PSDA, it may not be appropriate for the real-time SSVEP-based BCI system when it has short time window length because it uses sinusoidal signals as references. Therefore, the two methods are not efficient for the real-time BCI system that requires a short TW and a high recognition accuracy. To overcome this limitation of the conventional methods, this paper proposes a frequency recognition method with a combination of CCA and PSDA using the difference between powers of canonical variables obtained from the results of CCA. Experimental results show that the performance of the combination of CCA and PSDA is better than that of CCA for the case of a short TW.

Analysis of RP Power Amplifier Nonlinearity and BER Characteristics for Multi­Carrier Transmission System (다중반송 전송시스템을 위한 RF 전력증폭기의 비선형 특성과 BER관계 분석)

  • 신동환;이영철
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.8
    • /
    • pp.1612-1620
    • /
    • 2003
  • This papers describes a nonlinear transfer function modelling of designed GaAs FET power amplifier by measured and simulated values of designed PA amplifier for multi­carrier transmission system, With the results of PA nonlinearity characteristic, we can estimates AM­AM and AM­PM of designed PA. According to the estimated nonlinear characteristics, we can analysis the ACPR of PA for spectral regrowth, the error vector measurement(EVM) of constallation signals and bit error rate of QPSK and 64­QAM. The suggested nonlinear modelling results are used to get an accurate estimate of digital characteristics between PA amplifier and wireless multi­carrier transmission system using OFDM.

Vibration Analysis of Composite Satellite Antenna by Acoustic Excitation (음향 가진에 의한 위성 안테나의 진동해석)

  • ;;;;;Horst Stockburger
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.05a
    • /
    • pp.123-126
    • /
    • 2002
  • Acoustic vibration analysis has been performed using random vibration analysis module of MSC/NASTRAN to evaluate the safety of the composite satellite antenna structure under the acoustic pressure from the launch vehicle. It was found that maximum $3\sigma$ stress by acoustic excitation was less than allowable stress.

  • PDF

Wavelet-transform-based damping identification of a super-tall building under strong wind loads

  • Xu, An;Wu, Jiurong;Zhao, Ruohong
    • Wind and Structures
    • /
    • v.19 no.4
    • /
    • pp.353-370
    • /
    • 2014
  • A new method is proposed in this study for estimating the damping ratio of a super tall building under strong wind loads with short-time measured acceleration signals. This method incorporates two main steps. Firstly, the power spectral density of wind-induced acceleration response is obtained by the wavelet transform, then the dynamic characteristics including the natural frequency and damping ratio for the first vibration mode are estimated by a nonlinear regression analysis on the power spectral density. A numerical simulation illustrated that the damping ratios identified by the wavelet spectrum are superior in precision and stability to those values obtained from Welch's periodogram spectrum. To verify the efficiency of the proposed method, wind-induced acceleration responses of the Guangzhou West Tower (GZWT) measured in the field during Typhoon Usagi, which affected this building on September 22, 2013, were used. The damping ratios identified varied from 0.38% to 0.61% in direction 1 and from 0.22% to 0.59% in direction 2. This information is expected to be of considerable interest and practical use for engineers and researchers involved in the wind-resistant design of super-tall buildings.

Anti-correlated hard and soft X-ray lags in the Z source GX 5-1

  • Sriram, K.;Choi, C.S.;Rao, A.R.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.149.2-149.2
    • /
    • 2011
  • We performed the cross-correlation analysis on energy-dependent light curves of the Z-type source GX 5-1. We observed X-ray delays of a few hundred seconds between hard (16-30 keV) and soft (2-5 keV) X-ray light curves. During these phenomena, the centroid frequency of horizontal branch oscillation (HBO) was found to shift to lower or higher frequency indicating towards the dynamical movement of a Compton cloud or an inner disk front. Both eastern and western approaches were used to unfold the X-ray continuum and systematic changes were observed in soft and hard X-ray spectral components. Simultaneous energy spectral and power density spectral study shows that the production of HBOs is closely related to the Comptonizing region rather than the accretion disk. We discuss the results in the context of re-condensation of coronal material in the inner accretion disk region.

  • PDF