• 제목/요약/키워드: Power Signal

검색결과 5,933건 처리시간 0.029초

$0.35{\mu}m$ 표준 CMOS 공정에서 제작된 저전력 다중 발진기 (A Low Power Multi Level Oscillator Fabricated in $0.35{\mu}m$ Standard CMOS Process)

  • 채용웅;윤광열
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권8호
    • /
    • pp.399-403
    • /
    • 2006
  • An accurate constant output voltage provided by the analog memory cell may be used by the low power oscillator to generate an accurate low frequency output signal. This accurate low frequency output signal may be used to maintain long-term timing accuracy in host devices during sleep modes of operation when an external crystal is not available to provide a clock signal. Further, incorporation of the analog memory cell in the low power oscillator is fully implementable in a 0.35um Samsung standard CMOS process. Therefore, the analog memory cell incorporated into the low power oscillator avoids the previous problems in a oscillator by providing a temperature-stable, low power consumption, size-efficient method for generating an accurate reference clock signal that can be used to support long sleep mode operation.

고장점 탐색 장치를 위한 H/W 설계 (H/W Design for Fault Location System on Underground Power Cable System)

  • 이재덕;류희석;정동학;최상봉;남기영;정성환;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.709-711
    • /
    • 2005
  • Developing fault location system for underground power cable which can detect its fault location exactly require very high speed data acquisition and signal processing capability. We are developing fault location system which is different from conventional fault locator. This fault location system monitor underground power cable by using on-line speed current sensor and if there are an accident, it record its transient signal and calculate fault location by analyzing it. Signals which acquired when power cable fault arise, showed transient characteristics and its frequency band is very hish. So, to develop fault location system, we designed special high speed data acquisition and signal processing board. In this thesis, we describe on data acquisition and signal processing H/W design for fault location system on underground power cable.

  • PDF

원전 복수계통 열교환기의 이음 원인 분석 (Abnormal Sound from Heat Exchanger of Condensate Water System at Nuclear Power Plant)

  • 이준신;이욱륜;김태룡
    • 한국소음진동공학회논문집
    • /
    • 제26권4호
    • /
    • pp.469-474
    • /
    • 2016
  • Abnormal sound was heard from a heat exchanger of condensate water system in a nuclear power plant, which was identified as impact sound of a loose part later. Nuclear power plants are normally equipped with loose part monitoring system for primary water system, but not for secondary water system. The abnormal sound was analyzed by using the impact signal-processing methodology based on the Hertz theory. The predicted results for impact location and size of the loose part showed good agreement with those of the actual loose part found during the overhaul period in the plant. So, this analysis methodology for the impact signal will be widely utilized for the primary and secondary side of the nuclear power plant.

고출력 위협신호 모의장치 개발 및 추적레이다 연동 (Development of High power Threat Signal Simulator and Interfacing Tracking Radar)

  • 곽용길
    • 한국항행학회논문지
    • /
    • 제26권2호
    • /
    • pp.85-90
    • /
    • 2022
  • 본 연구에서는 항공기 체계의 성능을 시험하기 위해 시험 대상 항공기에 실제 위협과 유사한 신호를 고출력으로 송신할 수 있는 위협신호 모의 장치를 설계하였다. 고출력 위협신호 모의장치는 광대역(UHF대역, L대역, S대역, X 대역)의 통신신호, 레이다 신호를 송신하는 것이 가능해야 하며, 추적 레이다와 연동을 통해 항공기에 정확하게 지향하여 신호를 송신하는 제어시스템이 필요하다. 개발된 장비의 신호의 세기는 신호의 종류에 따라서 63 dBm, 93 dBm이상이며, 추적 정밀도는 0.1°이하로 요구되는 전기적/기계적 성능을 모두 만족함을 확인하였고, 추적 레이다 연동을 통해 고출력 위협신호 모의장치의 안테나가 항공기 위치로 신호를 정확하게 지향할 수 있음을 확인하였다.

A CMOS 180-GHz Signal Source with an Integrated Frequency Doubler

  • Kim, Jungsoo;Seo, Myeong-Gyo;Rieh, Jae-Sung
    • Journal of electromagnetic engineering and science
    • /
    • 제16권4호
    • /
    • pp.229-231
    • /
    • 2016
  • A 180-GHz signal source based on a 65-nm CMOS technology has been developed in this study. The 180-GHz signal source consists of a 90-GHz fundamental-mode Colpitts oscillator and a 180-GHz frequency doubler. A coupled-line is employed to couple two oscillator cores for generating a differential signal, which is delivered to the input of the differential-mode doubler. The fabricated signal source operates from 181.2 to 182.4 GHz with output power varying from -15.3 to -10.8 dBm. The peak output power was -10.53 dBm at 181.3 GHz with a DC power consumption of 42 mW, and the associated phase noise was -71 dBc/Hz at 1 MHz offset.

전력선 모뎀을 이용한 선박엔진 성능분석기의 신호전달방식의 개선 (Improvement of Signal Transmission Method of Ship's Engine Performance Analyzer(SEPA) using PLM)

  • 김건우;양현숙;임현정;최준길;이성근;김윤식
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 후기학술대회논문집
    • /
    • pp.53-54
    • /
    • 2005
  • This paper describes that send some signal from encoder attached to crankshaft of marine-engine to measuring instrument using power line modem(PLM) and display cylinder pressure, rpm and etc. on LCD. Conventional method that sends signal along the long signal line has some inconvenience from too long signal line length caused by huge volume of ship's engine. Power line modem can have short signal line from outlets to measuring instrument. Because it use exist power line for send signals, so it have low installation cost and could have good merits in job sites. Through this experiment, pressure in cylinder, engine rpm and etc. signals through PLM are well recognized at measuring instrument.

  • PDF

균열 진전에 따라 발생되는 AE신호 특성 분석 (AE Signal Characteristic Analysis caused by Crack Growth)

  • 김원철;김재구;구동식;김효중;최병근
    • 동력기계공학회지
    • /
    • 제14권6호
    • /
    • pp.41-46
    • /
    • 2010
  • Acoustic emission (AE) technique is a well-known non-destructive test technique. Fatigue crack growth test was performed using SM53C to check up the AE signal occurred by crack growth, so AE system was used to detect the crack signal. Features calculated by the AE signals were analyzed to evaluate the steps divided the crack growth into three. The steps, initiation, growth and breaking, were separated by velocity of the crack growth. Time waveform and power spectrum were created by the AE signal of each one of the steps and compared. In the feature domains, it was found that AE values changed rapidly as the velocity of the crack increasing.

동일 주파수 무선통신 시스템의 발진방지를 위한 간섭잡음제거기 (Interference Cancellation System to Prevent the Oscillation of the Wireless Communication System using the Same Frequency)

  • 김선진;김남영
    • 한국전기전자재료학회논문지
    • /
    • 제16권3호
    • /
    • pp.253-262
    • /
    • 2003
  • In this paper, the interference cancellation system, which is used to cancel the feedback signal in the wireless communication system with the same frequency, is studied. The time varying feedback signal generated from transmitter antenna to receiver antenna reduces the performance of the receiver system. the interference cancellation system using adaptive feedback method(AF-ICS) is suggested to prevent the oscillation of the receiver system and maintain the maximum output power of the power amplifier by the reduction of time-varying feedback signal and also this paper conforms that the oscillation disappears from the output signal by cancellation of the feedback signal and the total output power is satisfied the system specification.

Scaling Factor Design Based Variable Step Size Incremental Resistance Maximum Power Point Tracking for PV Systems

  • Ahmed, Emad M.;Shoyama, Masahito
    • Journal of Power Electronics
    • /
    • 제12권1호
    • /
    • pp.164-171
    • /
    • 2012
  • Variable step size maximum power point trackers (MPPTs) are widely used in photovoltaic (PV) systems to extract the peak array power which depends on solar irradiation and array temperature. One essential factor which judges system dynamics and steady state performances is the scaling factor (N), which is used to update the controlling equation in the tracking algorithm to determine a new duty cycle. This paper proposes a novel stability study of variable step size incremental resistance maximum power point tracking (INR MPPT). The main contribution of this analysis appears when developing the overall small signal model of the PV system. Therefore, by using linear control theory, the boundary value of the scaling factor can be determined. The theoretical analysis and the design principle of the proposed stability analysis have been validated using MATLAB simulations, and experimentally using a fixed point digital signal processor (TMS320F2808).

오신호 입력에 따른 펌프의 고장징후 조기감지 성능분석 (Performance Analysis on Early Detection of Fault Symptom of a Pump with Abnormal Signals)

  • 정재영;이병오;김형균;김대웅
    • 동력기계공학회지
    • /
    • 제20권2호
    • /
    • pp.66-72
    • /
    • 2016
  • As a method to improve the equipment reliability, early warning researches that can be detected fault symptom of an equipment at an early stage are being performed out among developed countries. In this paper, when abnormal signal is input to actual normal signal of a pump, early detection studies on pump's fault symptom were carried out with auto-associative kernel regression as an advanced pattern recognition algorithm. From analysis, correlations among power of motor driving pump, discharge flow of pump, power output of pump, and discharge pressure of pump are exited. When the abnormal signal is input to one of those normal signals, the other expected values are changed due to the influence of the abnormal signal. Therefore, the fault symptom of pump through the early-warning index is able to detect at an early stage.