• Title/Summary/Keyword: Power Response

Search Result 3,866, Processing Time 0.03 seconds

Development of Demand Response Operation System for Load Aggregators (부하관리사업자용 수요반응 운영 시스템 개발)

  • Kim, Ji-Hui;Moon, Guk-Hyun;Joo, Sung-Kwan;Oh, Jae-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.12
    • /
    • pp.2221-2224
    • /
    • 2011
  • During an emergency due to a shortage of power, a load aggregator (LA) can use the demand response operation system to deploy demand response resources (DRRs) through various demand response (DR) programs. This paper introduces the demand response operation system for a load aggregator to manage various demand response resources in a smart grid environment.

Digital Control of an AC/DC Converter using the Power Balance Control Technique with Average Output Voltage Measurement

  • Wisutmetheekorn, Pisit;Chunkag, Viboon
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.88-97
    • /
    • 2012
  • This paper presents a method for the digital control of a high power factor AC/DC converter employing the power balance control technique to achieve a fast response of the output voltage control. To avoid the effects of an output voltage ripple in the voltage control loop, the average output voltage is sampled and used as a feedback signal for the output voltage controller. The proposed control technique was verified by simulations using MATLAB/Simulink and its implementation was realized by a dsPIC30F4011 digital signal processor to control a CUK topology AC/DC converter with a 48V output voltage and a 250 W output power. The experimental results agree with the simulation results. The proposed control technique achieves a fast transient response with a lower line current distortion than is achieved when using a conventional proportional-integral controller and the power balance control technique with the conventional sampling method.

Application of Fuzzy Algorithm with Learning Function to Nuclear Power Plant Steam Generator Level Control

  • Park, Gee-Yong-;Seong, Poong-Hyun;Lee, Jae-Young-
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1993.06a
    • /
    • pp.1054-1057
    • /
    • 1993
  • A direct method of fuzzy inference and a fuzzy algorithm with learning function are applied to the steam generator level control of nuclear power plant. The fuzzy controller by use of direct inference can control the steam generator in the entire range of power level. There is a little long response time of fuzzy direct inference controller at low power level. The rule base of fuzzy controller with learning function is divided into two parts. One part of the rule base is provided to level control of steam generator at low power level (0%∼30% of full power). Response time of steam generator level control at low power level with this rule base is shown generator level control at low power level with this rule base is shown to be shorter than that of fuzzy controller with direct inference.

  • PDF

Output Phase Synchronization Method of Inverter for Parallel Operation of Uninterruptible Power System (무정전전원장치 병렬운전을 위한 인버터의 출력 위상 동기화 방법)

  • Kim, Heui-Joo;Park, Jong-Myeon;Oh, Se-Hyung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.3
    • /
    • pp.235-241
    • /
    • 2020
  • In this paper, we propose the bus/bypass synchronization phase lock loop (B-Sync PLL) method using each phase voltage controller of a parallel UPS inverter. The B-Sync PLL included in each phase voltage control system of parallel UPS inverters has the transient response and the phase synchronization error at grid normal or blackout. The validity of this method is verified by simulation and experiment. As a result, the parallel UPS inverters using the proposed method confirmed that the output phase was continuously synchronized when a grid blackout, improving the transient response characteristics for stable load power supply and equal load sharing.

Improved Transient Response of Distributed Energy Resources Inverters to PQ Control using Decoupling (분산전원용 인버터의 유효 무효전력 감결합을 통한 PQ제어 과도상태 특성개선)

  • Choi, Chul-Hoon;Choi, Jong-Woo;Lee, Chang-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.438-444
    • /
    • 2012
  • This paper deals with the active and reactive power control of Grid connected system. It was shown that active power and reactive power can be dependently controlled with two individually adaptable parameters. The two parameters are power angle and voltage magnitude. Transient state will occur with active or reactive power reference value variation. This paper presents a new control strategy for active and reactive power control of less interaction and improved transient response. The paper details the control technique by the mathematical and electrical network analysis of the methodology. The performance was verified through computer simulation using MATLAB Simulink and experiment.

Improvement Methods in NPP's Radiation Emergency Plan: An Administrative Approach (행정적 대응을 중심으로 본 원전 방사선비상계획 개선방안)

  • Lee, Yoon-Wook;Yang, He-Sun
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.3
    • /
    • pp.151-154
    • /
    • 2009
  • The Radiation Emergency Plan (REP) can be divided into a technical and an administrative responses. The domestic NPP's REPs are reviewed from the viewpoint of the administrative response and improvement methods are also suggested in this treatise. The fields of the reviews are the composition of the emergency response organizations, the activation criteria of the organizations, the selection of the staffings and the reasonableness of the REP's volume. In addition, the limitations of the current radiation exercises are reviewed and the improvement method of the exercise is presented. It is expected that the suggested recommendations will be helpful in establishing useful REPs and making practical radiation exercises in Korea.

A Real-Time Demand Response Management Using Smart Box (스마트 박스를 활용한 실시간 수요관리)

  • Ko, Dong-Kwan;Bea, Jun-Cheol;Min, Kyoung-Chon;Lee, Jae-Kyu
    • Transactions of the KSME C: Technology and Education
    • /
    • v.4 no.1
    • /
    • pp.57-62
    • /
    • 2016
  • The Demand Response Market is a nation-wide power and energy management program of electric power demand response operated by KPX (Korea Power eXchange). Therefore, any savings could be determined by KEPCO's AMR(Automatic Meter Reading) data. However, the customers and the service providers participating in the market could not know the real time value due to the 15 minute or even more delayed AMR data communicated. Here, a new concept of a smart box has been introduced and demonstrated to provide the real time saving values compared to the current KEPCO's AMR data approach.

Study on load tracking characteristics of closed Brayton conversion liquid metal cooled space nuclear power system

  • Li Ge;Huaqi Li;Jianqiang Shan
    • Nuclear Engineering and Technology
    • /
    • v.56 no.5
    • /
    • pp.1584-1602
    • /
    • 2024
  • It is vital to output the required electrical power following various task requirements when the space reactor power supply is operating in orbit. The dynamic performance of the closed Brayton cycle thermoelectric conversion system is initially studied and analyzed. Based on this, a load tracking power regulation method is developed for the liquid metal cooled space reactor power system, which takes into account the inlet temperature of the lithium on the hot side of the intermediate heat exchanger, the filling quantity of helium and xenon, and the input amount of the heat pipe radiator module. After comparing several methods, a power regulation method with fast response speed and strong system stability is obtained. Under various changes in power output, the dynamic response characteristics of the ultra-small liquid metal lithium-cooled space reactor concept scheme are analyzed. The transient operation process of 70 % load power shows that core power variation is within 30 % and core coolant temperature can operate at the set safety temperature. The second loop's helium-xenon working fluid has a 65K temperature change range and a 25 % filling quantity. The lithium at the radiator loop outlet changes by less than ±7 K, and the system's main key parameters change as expected, indicating safety. The core system uses less power during 30 % load power transient operation. According to the response characteristics of various system parameters, under low power operation conditions, the lithium working fluid temperature of the radiator circuit and the high-temperature heat pipe operation temperature are limiting conditions for low-power operation, and multiple system parameters must be coordinated to ensure that the radiator system does not condense the lithium working fluid and the heat pipe.

Power Consumption Management Algorithm Based on OpenADR (OpenADR 기반의 전력사용량 관리 알고리즘)

  • Kim, Jeong-Uk
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.12
    • /
    • pp.991-994
    • /
    • 2016
  • This paper presents a load management method based on OpenADR of smart grid. Previous demand side algorithm is restricted on reducing peak power. But, in this paper we suggest a method of performing the energy-saving control according to the power price utilizing building automatic control system installed on the customer side in the case of hourly differential pricing signal is transmitted to the open automated demand response system. And, we showed the integrated demand management software for 3 buildings.

Instantaneous Power Control of Permanent Magnet AC Motor (영구자석형 교류전동기의 순시전력제한)

  • Youn, K.S.;Lee, C.H.;Hwang, J.H.;Kwon, W.H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.274-277
    • /
    • 1996
  • Vector controlled PMAC(Permanent Magnet AC) motor, with rare-earth permanent magnet, are suitable for servo system demanding fast speed response. However, abrupt acceleration and deceleration control for fast response requires big instantaneous input power. So general PI control of PMAC motors can't be applied for limited power supply system like airplane or portable equipment because of input power fluctuation. Proposed technique to restrain instantaneous input power use variable power limit depends on airgap flux power. Stability check for proposed system is done.

  • PDF