• Title/Summary/Keyword: Power Response

Search Result 3,866, Processing Time 0.032 seconds

Seismic Analysis of Power Plant Piping System (발전소 배관계의 내진해석)

  • Kim, Jeong-Hyun;Lee, Young-Shin;Kim, Yeon-Whan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.480-485
    • /
    • 2011
  • In this study, the seismic analysis of power plant piping system was performed using finite element model. This study was performed by ANSYS 12.1. For qualification of power plant piping system, the response spectrum analysis was performed using the given operating basis earthquake(OBE) and safe shutdown earthquake(SSE) floor response spectrum. The maximum stresses of power plant piping system were 166 MPa under OBE condition and 281 MPa under SSE condition. Thus, it can shown that the structural integrity of tpower plant piping system has a stable structure for seismic load conditions.

  • PDF

Unit Response Optimizer mode Design of Ultra Super Critical Coal-Fired Power Plant based on Fuzzy logic & Model Predictive Controller (퍼지 로직 및 모델 예측 제어기 적용을 통한 초초임계압 화력발전소 부하 응답 최적화 운전 방법 설계)

  • Oh, Ki-Yong;Kim, Ho-Yol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2285-2290
    • /
    • 2008
  • Even though efficiency of coal-fired power plant is proportional to operating temperature, increasement of operating temperature is limited by a technological level of each power plant component. It is an alternative plan to increase operating pressure up to ultra super critical point for efficiency enhancement. It is difficult to control process of power plant in ultra super critical point because that point has highly nonlinear characteristics. In this paper, new control logic, Unit Response Optimizer Controller(URO Controller) which is based on Fuzzy logic and Model Predictive Controller, is introduced for better performance. Then its performance is tested and analyzed with design guideline.

Effects of Low Power Laser on Pain Response and Axonal Regeneration in Rat Models with Sciatic Nerve Crush Injury

  • Lee, Hong-Gyun;Kim, Yong-Eok;Min, Kyung-Ok;Yoo, Young-Dae;Kim, Kyung-Yoon;Kim, Gye-Yeop
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.3 no.1
    • /
    • pp.345-355
    • /
    • 2012
  • This study purposed to examine the effect of low power laser on pain response and axonal regeneration. In order to prepare peripheral nerve injury models, we crushed the sciatic nerve of Sprague-Dawley rats and treated them with low power laser for 21 days. The rats were divided into 4 groups: normal group(n=10); control group(n=10) without any treatment after the induction of sciatic nerve crush injury; experimental group I(n=10) treated with low power laser(0.21$mJ/mm^2$) after the induction of sciatic nerve crush injury; and experimental group II(n=10) treated with low power laser(5.25$mJ/mm^2$) after the induction of sciatic nerve crush injury. We measured spontaneous pain behavior(paw withdrawal latency test) and mechanical allodynia(von Frey filament test) for evaluating pain behavioral response, and measured the sciatic function index for evaluating the functional recovery of peripheral nerve before the induction of sciatic nerve crush injury and on day 1, 7, 14 and 21 after the induction. After the experiment was completed, changes in the H & E stain and toluidine blue stain were examined histopathologically, and changes in MAG(myelin associated glycoprotein) and c-fos were examined immunohistologically. According to the results of this study, when low power laser was applied to rat models with sciatic nerve crush injury for 21 days and the results were examined through pain behavior evaluation and neurobehavioral, histopathological and immunohistological analyses, low power laser was found to affect pain response and axonal regeneration in both experimental group I and experimental group II. Moreover, the effect on pain response and axonal regeneration was more positive in experimental group I to which output 0.21$mJ/mm^2$ was applied than in experimental group II to which 5.25$mJ/mm^2$ was applied.

The Automatic Demand Response Systems Design for Electric Power Control of Home Appliances (가전기기의 전력 제어를 위한 자동 수요반응 시스템 설계)

  • Kim, Su-hong;Jung, Jin-uk;Song, Ho-jin;Hwang, Min-tae;Jin, Kyo-hong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.228-231
    • /
    • 2015
  • Recently, the electric power consumption concentrated in specific seasons and time causes the unstable power supply. To resolve this problem, smart grid has emerged as an alternative to consume the power, efficiently. Smart grid that combines ICT with the existing electrical grid includes demand response as a core technology. Demand response enable the power consumption effectively by offering a variety of informations, such as power consumption, charges expected, etc., for consumers who voluntarily participate in the electricity markets. In this paper, we design the automatic demand response systems based on SEP 2.0 for the efficient power control of home appliances in the smart grid environments.

  • PDF

Approximate Equivalent-Circuit Modeling and Analysis of Type-II Resonant Immittance Converters

  • Borage, Mangesh;Nagesh, K.V.;Bhatia, M.S.;Tiwari, Sunil
    • Journal of Power Electronics
    • /
    • v.12 no.2
    • /
    • pp.317-325
    • /
    • 2012
  • Resonant immittance converter (RIC) topologies can transform a current source into a voltage source (Type-I RICs) and vice versa (Type-II RICs), thereby making them suitable for many power electronics applications. RICs are operated at a fixed frequency where the resonant immittance network (RIN) exhibits immittance conversion characteristics. It is observed that the low-frequency response of Type-II RINs is relatively flat and that the state variables associated with Type-II RINs affect the response only at the high frequencies in the vicinity of the switching frequency. The overall response of a Type-II RIC is thus dominated by the filter response, which is particularly important for the controller design. Therefore, an approximate equivalent circuit model and a small-signal model of Type-II RICs are proposed in this paper, neglecting the high-frequency response of Type-II RINs. While the proposed models greatly simplify and speed-up the analysis, it adequately predicts the open-loop transient and small-signal ac behavior of Type-II RICs. The validity of the proposed models is confirmed by comparisons of their results with those obtained from a cycle-by-cycle simulation and with an experimental prototype.

Modeling of Hanlim's gas turbine generator & qualitative analysis of PSS operation (한림가스터빈 발전기/제어계의 모델링 및 PSS 동작의 정성적 분석)

  • Choi, K.S.;Moon, Y.H.;Kim, D.J.;Choo, J.B.;Lyu, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.95-98
    • /
    • 1996
  • Response speed of generator/control system kas increased with the aid of the development of power electronics. Even though it is desirable to enhance response speed for the control system(AVR/Gov) of generator itself, in case a certain generator/control system with high response excitation system is connected with bulk power system, terminal voltage and active power of some generators can oscillate with adjoining generators or near area when even a little of disturbance take place. PSS(Power System Stabilizer) is used to damp rotor swing by adding the supplementary signal in phase with speed. As the stable AVR response is very important before PSS is installed, modeling and analysis of generator/control system was performed. Next we have analysed PSS response of Hanlim's gas turbine by transmission line open/close test.

  • PDF

Expansion of power allocation using response rate per stratum (층별 응답률을 사용한 멱배정 방법의 확장)

  • Park, Hyeonah
    • The Korean Journal of Applied Statistics
    • /
    • v.34 no.5
    • /
    • pp.671-683
    • /
    • 2021
  • Power allocation is a technique that evenly allocates samples for each stratum, although the overall efficiency of the allocation is less than that of optimal allocation, and it is often used as a square root proportional allocation in real survey. Also, considering the non-response that occurs in real survey, a larger sample size is used than that in the theoretical formula. In this study, in determining the sample size for each stratum, we study the new methods of allocating by adding information on the response rate per each stratum to power allocation method. The proposed allocation methods are compare with proportional, optimal, and square root proportional allocation in simulation. In addition, the comparison with the proportional and optimal allocation to which the response rate was added is examined through simulation. As a result, we examine the advantages and disadvantages of the allocation methods.

Verification of an Autonomous Decentralized UPS System with Fast Transient Response Using a FPGA-Based Hardware Controller

  • Yokoyama, Tomoki;Doi, Nobuaki;Ishioka, Toshiya
    • Journal of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.507-515
    • /
    • 2009
  • This paper proposes an autonomous decentralized control for a parallel connected uninterruptible power supply (UPS) system based on a fast power detection method using a FPGA based hardware controller for a single phase system. Each UPS unit detects only its output voltage and current without communications signal exchange and a quasi dq transformation method is applied to detect the phase and amplitude of the output voltage and the output current for the single phase system. Fast power detection can be achieved based on a quasi dq transformation, which results in a realization of very fast transient response under rapid load change. In the proposed method, the entire control system is implemented in one FPGA chip. Complicated calculations are assigned to hardware calculation logic, and the parallel processing circuit makes it possible to realize minimized calculation time. Also, an Nios II CPU core is implemented in the same FPGA chip, and the software can be applied for non-time critical calculations. Applying this control system, an autonomous decentralized UPS system with very fast transient response is realized. Feasibility and stable operation are confirmed by means of an experimental setup with three UPSs connected in parallel. Also, rapid load change is applied and excellent performance of the system is confirmed in terms of transient response and stability.

Field measurements of natural periods of vibration and structural damping of wind-excited tall residential buildings

  • Campbell, S.;Kwok, K.C.S.;Hitchcock, P.A.;Tse, K.T.;Leung, H.Y.
    • Wind and Structures
    • /
    • v.10 no.5
    • /
    • pp.401-420
    • /
    • 2007
  • Field measurements of the wind-induced response of two residential reinforced concrete buildings, among the tallest in the world, have been performed during two typhoons. Natural periods and damping values have been determined and compared with other field measurements and empirical predictors. Suitable and common empirical predictors of natural period and structural damping have been obtained that describe the trend of tall, reinforced concrete buildings whose structural vibrations have been measured in the collection of studies in Hong Kong compiled by the authors. This data is especially important as the amount of information known about the dynamic parameters of buildings of these heights is limited. Effects of the variation of the natural period and damping values on the alongwind response of a tall building for serviceability-level wind conditions have been profiled using the gust response factor approach. When using this approach on these two buildings, the often overestimated natural periods and structural damping values suggested by empirical predictors tended to offset each other. Gust response factors calculated using the natural periods and structural damping values measured in the field were smaller than if calculated using design-stage values.

Power consumption of a Quick-Response Liquid Powder Display ($QR-LPD^{(R)}$)

  • Hattori, Reiji;Masuda, Yoshitomo;Nihei, Norio;Sakurai, Ryo;Yamada, Shuhei
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.845-849
    • /
    • 2005
  • Quick-Response Liquid Powder Display ($QR-LPD^{(R)}$) is a promising device for ultra-low-power applications. Several driving methods for this display were investigated in terms of image quality and power consumption. The power consumed both in a panel and in the output circuits of driver LSIs was evaluated by analog circuit simulation and discussed.

  • PDF