• 제목/요약/키워드: Power Response

검색결과 3,893건 처리시간 0.034초

전기철도에서의 고조파 발생과 계통응답특성(II) - 고조파 측정분석을 중심으로 - (Harmonic Generation and System Response Chartcteristics in Electrified Railway(II) - Focused on Measurement and Analysis -)

  • 오광해;이한민
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 춘계학술대회 논문집
    • /
    • pp.499-504
    • /
    • 2003
  • Harmonic current originating from electric locomotives can be magnified due to the impedance characteristics of power supply circuit and bring about various problems. That is, electromagnetic interference with communication lines, operational trouble in signaling, overheat and/or vibration in power capacitor, mis-operation in protection relay and so on. Therefore, the exact assessment of the harmonic current flow must be undertaken at design and planning stage for the electric traction systems. For these reasons, this study propose a new approach to model and to analyse traction power feeding system focused on system response to current and voltage harmonic(PART I ). Measurements of harmonics are also performed for railway power supply systems under normal operation. Spectrum and distortion analyses in measurement data are variously described in PART II

  • PDF

Adaptive Queue Management Based On the Change Trend of Queue Size

  • Tang, Liangrui;Tan, Yaomu
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제13권3호
    • /
    • pp.1345-1362
    • /
    • 2019
  • Most active queue management algorithms manage network congestion based on the size of the queue but ignore the network environment which makes queue size change. It seriously affects the response speed of the algorithm. In this paper, a new AQM algorithm named CT-AQM (Change Trend-Adaptive Queue Management) is proposed. CT-AQM predicts the change trend of queue size in the soon future based on the change rate of queue size and the network environment, and optimizes its dropping function. Simulation results indicate that CT-AQM scheme has a significant improvement in loss-rate and throughput.

Axial Power Distribution Calculation Using a Neural Network in the Nuclear Reactor Core

  • Kim, Y. H.;K. H. Cha;Lee, S. H.
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 추계학술발표회논문집(1)
    • /
    • pp.58-63
    • /
    • 1997
  • This paper is concerned with an algorithm based on neural networks to calculate the axial power distribution using excore defector signals in the nuclear reactor core. The fundamental basis of the algorithm is that the detector response can be fairly accurately estimated using computational codes. In other words, the training set, which represents relationship between detector signals and axial power distributions, for the neural network can be obtained through calculations instead of measurements. Application of the new method to the Yonggwang nuclear power plant unit 3 (YGN-3) shows that it is superior to the current algorithm in place.

  • PDF

전력계통의 전압안정도향상을 위한 감시제어시스템 개발 (A Development of Monitoring and Control System for Improved the Voltage Stability in the Power System)

  • 이현철;정기석;박지호;백영식
    • 전기학회논문지
    • /
    • 제62권4호
    • /
    • pp.437-443
    • /
    • 2013
  • This paper was developed a monitoring and control system to use reactive power control algorithm. This algorithm could be improved voltage stability in power system. This method was controlled the voltage for stability improvement, effective usage of reactive power, and the increase of the power quality. PMS(Power Management System) has been calculate voltage sensitivity, and control reactive power compensation device. The voltage control was used to the FACTS, MSC/MSR(Mechanically Switched Capacitors/Reactors), and tap of transformer in power system. The reactive power devices in power system were control by voltage sensitivity ranking of each bus. Also, to secure momentary reactive power, it had been controlled as the rest of reactive power in the each bus. In here, reactive power has been MSC/MSR. The simulation result, First control was voltage control as fast response control of FACTS. Second control was voltage control through the necessary reactive power calculation as slow response control of MSR/MSR. Third control was secured momentary reactive reserve power. This control was method by cooperative control between FACTS and MSR/MSC. Therefore, the proposed algorithm was had been secured the suitable reactive reserve power in power system.

Control Strategy Based on Equivalent Fundamental and Odd Harmonic Resonators for Single-Phase DVRs

  • Teng, Guofei;Xiao, Guochun;Hu, Leilei;Lu, Yong;Kafle, Yuba Raj
    • Journal of Power Electronics
    • /
    • 제12권4호
    • /
    • pp.654-663
    • /
    • 2012
  • In this paper, a digital control strategy based on equivalent fundamental and odd harmonic resonators is proposed for single-phase DVRs. By using a delay block, which can be equivalent to a bank of resonators, it rejects the fundamental and odd harmonic disturbances effectively. The structure of the single closed-loop control system consists of a delay block, a proportional gain and a set of zero phase notch filters. The principle of the controller design is discussed in detail to ensure the stability of the system. Both the supply voltage and the load current feedforwards are used to improve the response speed and the ability to eliminate disturbances. The proposed controller is simple in terms of its structure and implementation. It has good performances in harmonic compensation and dynamic response. Experimental results from a 2kW DVR prototype confirm the validity of the design procedure and the effectiveness of the control strategy.

빌딩용 직류배전 시스템의 3상 AC/DC 컨버터의 기동 시 과도상태 응답 개선 (Transient Response Improvement at Startup of Three Phase AC/DC Converter for DC Distribution System in Building Applications)

  • 신수철;이희준;이정효;나종국;원충연
    • 전력전자학회논문지
    • /
    • 제18권2호
    • /
    • pp.138-144
    • /
    • 2013
  • Most of the DC loads have had the sensitive characteristics electrically for input voltage. In this system, power converter is operated after connecting with DC loads to minimize the overshoot of the control voltage that may occur during connection of the loads. But whenever starting the power converter, parameters in circuit are different because power converter has been connected with diverse load types at each startup time. This is cause of a disadvantage to PI controller design of power converter. In this paper, the novel voltage control method using sliding mode control theory has proposed. This control method minimizes the overshoot of control voltage at startup of power converter. Despite the variations of the system parameters, the proposed voltage controller has fast response and robustness characteristics such as PI and sliding mode controllers. The proposed controller was applied to the three-phase AC/DC converter and each performance of controller was verified.

20피트급 파워보트의 구조강도 평가 및 최적화 (Structural Strength Assessment and Optimization for 20 Feet Class Power Boat)

  • 염재선;유재훈
    • 대한조선학회논문집
    • /
    • 제53권2호
    • /
    • pp.108-114
    • /
    • 2016
  • Recently, there has been a growing interest in marine leisure sports and high speed power boat for fishing. The prototype of 20 feet class power boat was developed and authors are joined in this government-led project. The research was performed to evaluate the optimal structure and design of the structural strength necessary to ensure the structural safety of the power boat. A new material ROCICORE fiber added to the mat and roving was adopted for high-power tenacity. ANSYS Workbench has been used to make the structural model, evaluate the strength and optimize the structural design. The response of the structure to quasi-static slamming loads according to the rules and regulations of ISO 12215-5, Lloyd’s Register of Shipping and Korean Register has been implemented and studied. An optimization study for the structural response is carried out by changing the plate thickness and section modulus of stiffeners. The power boat structure derived fuel efficiency is optimized by performing the best possible structural design to minimize the hull weight.

소규모 마이크로그리드에서 프로슈머관리시스템의 구현 (Implementation of Prosumer Management System for Small MicroGrid)

  • 임수연;이태원
    • 한국정보전자통신기술학회논문지
    • /
    • 제13권6호
    • /
    • pp.590-596
    • /
    • 2020
  • 상용전력망과 계통연계가 어려운 도서지역에서는 독립적인 마이크로그리드로 생산된 에너지를 효율적으로 관리할 수 있는 방법을 찾는 것은 매우 중요한 일이다. 본 논문에서는 태양광과 풍력의 하이브리드 모델을 적용한 소규모 마이크로그리드에서 생산된 전력을 전력계측기와 수집된 데이터의 응답속도 테스트를 거쳐 P2P전력거래를 위한 프로슈머관리시스템을 구현하였다. 마이크로그리드 프로슈머 관리시스템의 전력망은 Mesh구조로 이루어져 있으며 P2P전력거래는 3곳의 독립적으로 구축된 off-grid 사이트에서 전력계측기와 DC전력전송기를 이용하여 테스트하였고, 이때 전력계측기의 측정값은 전압(평균값) : 380V + 0.9V, 전류(평균값) : + 0.01A, 전력 : 1000W ( - 1W)로 오차 허용범위인 ±1%이내로 나타나 그 유의성을 확인하였다. 실시간으로 50개의 데이터를 동시 전송하여 메인화면 0.32초, 일 발전량 2.61초, 누적발전량 2.77초, 전력거래 0.11초 등의 응답속도가 나타나 서버의 안정화를 확인하였다. 따라서 본 시스템은 한국전력의 중계 없이 독립적인 망으로 활용될 수 있는 P2P 전력거래시스템으로서 그 타당성이 입증되었다.

변동요금제 기반의 DR 프로그램 운영 방안 연구 (Study on Implementing Dynamic Pricing to Demand Response System)

  • 유인협
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.541_542
    • /
    • 2009
  • This paper reviews the definition and background of dynamic pricing which is the essential element of demand response system. Also, economic efficiency and related issues on dynamic pricing are studied. Several issues on design and operation of demand response system, which can implement the dynamic pricing, are described. Therefore the results will be helpful for developing the demand response system with dynamic pricing.

  • PDF

탄성 댐퍼가 추가된 대형철골 구조물의 응답특성 (Response Characteristics Of Steel Frame Structures With Added Elastic Dampers)

  • Bae, Chun-Hee;Cho, Cheul-Whan;Yang, Kyeong-Hyeon;Park, Young-Pil
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.361.1-361
    • /
    • 2002
  • Coupling adjacent steel frame using elastic dampers fer control of response to low and moderate dynamic event is investigated in this paper. The complex modal superposition method is first used to determine dynamic characteristic, mainly modal damping ratio and modal frequency, of damper linked linear adjacent steel frame for fractical use. Dynamic response of steel frame linked by hydraulic-excitation method. (omitted)

  • PDF