• Title/Summary/Keyword: Power Response

Search Result 3,866, Processing Time 0.028 seconds

A Study on the Analysis Algorithm of Time Historical Response of Straight-line Structure by the Transfer Stiffness Coefficient Method (전달강성계수법에 의한 직선형 구조물의 시간 이력응답 해석알고리즘에 관한 연구)

  • Moon, D.H.;Kang, H.S.;Choi, M.S.
    • Journal of Power System Engineering
    • /
    • v.3 no.1
    • /
    • pp.74-79
    • /
    • 1999
  • This paper describes formulation for algorithm of time historical response analysis of vibration for straight-line structure. This method is derived from a combination of the transfer stiffness coefficient method and the Newmark method. And this present method improves the computational accuracy of the transient vibration response analysis remarkably owing to several advantages of the transfer stiffness coefficient method. We regarded the structure as a lumped mass system here. The analysis algorithm for the time historical response was formulated for the straight-line structure containing crooked, tree type system. The validity of the present method compared with the transfer matrix method and the Finite Element Method for transient vibration analysis is demonstrated through the numerical computations.

  • PDF

A Hydroelastic Response Analysis of Ships with Forward Speed in Regular Waves (규칙파중을 항행하는 선박의 유탄성응답해석)

  • Lee, S.C.;Bae, S.Y.
    • Journal of Power System Engineering
    • /
    • v.14 no.5
    • /
    • pp.48-55
    • /
    • 2010
  • When a large ship is advancing in waves, ship undergoes the hydroelastic response, which has influences on structural stability and the fatigue destruction etc. of the ship. Therefore, to predict accurate hydroelastic response, it is necessary to analyze hydroelastic response including fluid-structure interaction. In this research, a ship is divided into many hull elements to calculate the fluid forces and wave exciting forces on each elements using three-dimensional source distribution method. The calculated fluid forces and wave exciting forces are assigned to nodes of hull elements. The neighbor nodes are connected with elastic beam elements. We analyzed hydroelastic responses, and those are formulated by using finite element method. Particularly, to estimate the influence of forward speed on the hydroelastic responses, we use two different methods : Full Hull Rotation Method(FHRM) and Sectional Hull Rotation Method(SHRM).

Optimization of Microwave Extraction Conditions for Flammulina velutipes by Response Surface Methodology (반응표면분석에 의한 팽이버섯의 microwave 추출조건 최적화)

  • Kim, Hyun-Ku;Kim, Mi-Ok;Choi, Mal-Gum;Kim, Kong-Hwan
    • Korean Journal of Food Science and Technology
    • /
    • v.35 no.2
    • /
    • pp.222-228
    • /
    • 2003
  • Optimum extraction conditions for yield, browning color, electron-donating ability, nitrite-scavenging effect, total polyphenol content, and tyrosinase-inhibitory activity of Flammulina velutipes were determined using response surface methodology through central composite design. Yield of F. velutipes was affected by ethanol concentration, and browning color improved more with the increase of ethanol concentration than microwave power. Nitrite-scavenging effect was improved with increasing ethanol concentration and decreasing microwave power. Electron-donating ability and total polyphenol content were improved with increasing ethanol concentration and microwave power. Tyrosinase-inhibitory effect increased more with decrease in microwave power than with ethanol concentration. The optimal range of extraction conditions for effective component of F. velutipes were $47.21{\sim}76.05$ watt of microwave power, $10.25{\sim}43.56%$ of ethanol concentration, and 5.72 min of extraction time.

Suggestions to Improve the Effectiveness of National Radiological Emergency Response System (국내 방사능재난대응체계 실효성 제고를 위한 제언)

  • Moon, Joo Hyun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.2
    • /
    • pp.195-206
    • /
    • 2020
  • Although the national radiological emergency response system has been improved by incorporating lessons from the Fukushima nuclear power plant accident and recent domestic natural disasters, it has not fully incorporated these lessons. In addition, it cannot deal with a variety of aftermath of the radiological disaster. Even for the same disaster, the national emergency response system should comply with multiple domestic laws in our country. Furthermore, there are a few discrepancies between the articles of the domestic laws that the national radiological emergency response system should address. Therefore, this study investigates the characteristics of radiological disasters, examines articles on the domestic laws related to the national radiological emergency response system, and analyses the Japanese government's responses to the Fukushima nuclear power plant accident. Based on the results of the review, suggestions for the improvement of the national radiological emergency response system in terms of response organization and framework have been proposed in this study.

Digital Time-Domain Simulation of Ferroresonance of Potential Transformer in the 154 kV GAS Insulated Substation

  • Shim, Eung-Bo;Woo, Jung-Wook;Han, Sang-Ok
    • KIEE International Transactions on Power Engineering
    • /
    • v.11A no.4
    • /
    • pp.9-14
    • /
    • 2001
  • This paper reports a set of digital time-domain simulation studies conducted on 154 kV wound Potential Transformer(PT) int he 154 kV Gas Insulated Substation(GIS). The Electro-Magnetic Transient Program(EMTP) is used to develop the PT model and conduct the transient studies. The accuracy of the PT model is verified through comparison of the EMTP simulation results with those obtained from the field test results. The investigations shows that the developed model can accurately predict PT transient resonance, especially, the phenomenon of ferroresonance. The model is developed not only to determine impact of transients on PT response but also to design ferroresonance suppressor devices of PT. And it can also be used to predict PT transient response on power system monitoring and protection scheme.

  • PDF

Control Strategy of Improved Transient Response for a Doubly Fed Induction Generator in Medium Voltage Wind Power System under Grid Unbalance

  • Han, Daesu;Park, Yonggyun;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.246-247
    • /
    • 2013
  • This paper investigates control algorithms for a doubly fed induction generator with a back-to-back three-level neutral-point clamped voltage source converter in medium voltage wind power system under unbalanced grid conditions. Control algorithms to compensate for unbalanced conditions have been investigated with respect to four performance factors; fault ride-through capability, instantaneous active power pulsation, harmonic distortions, and torque pulsation. The control algorithm having zero amplitude of torque ripple shows the most cost-effective performance concerning torque pulsation. The least active power pulsation is produced by control algorithm that nullifies the oscillating component of the instantaneous stator active and reactive power. Combination of these two control algorithms depending on the operating requirements and depth of grid unbalance presents most optimized performance factors under the generalized unbalanced operating conditions leading to high performance DFIG wind turbine system. The proposed control algorithms are verified through transient response in the simulation.

  • PDF

Fast Transient Buck Converter Using a Hysteresis PWM Controller

  • Liu, Yong-Xiao;Zhao, Jin-Bin;Qu, Ke-Qing
    • Journal of Power Electronics
    • /
    • v.13 no.6
    • /
    • pp.991-999
    • /
    • 2013
  • In this paper, a fast transient buck converter using hysteresis PWM control is presented. The proposed control method is based on hysteresis control of the capacitor C voltage. This offers a faster transient response to meet the challenges of the power supply requirements for fast dynamic input and load changes. It also provides better stability and solves the compensation problem of the error amplifier in conversional voltage PWM control. Finally, the steady-state and dynamic operation of the proposed control method are analyzed and verified by simulation and experimental results.

Extraction Yields and Functional Properties of Garlic Extracts by Response Surface Methodology

  • Lim, Tae-Soo;Do, Jeong-Ryong;Kwon, Joong-Ho;Kim, Hyun-Ku
    • Food Science and Biotechnology
    • /
    • v.17 no.2
    • /
    • pp.379-383
    • /
    • 2008
  • Extraction characteristics of garlic and functional properties of corresponding extract were monitored by response surface methodology (RSM). Maximum extraction yield of 26.41% was obtained at microwave power of 146.29 W, ethanol concentration of 63.31 %, and extraction time of 5.88 min. At microwave power, ethanol concentration, and extraction time of 114.84 W, 58.83%, and 1.42 min, respectively, maximum electron-donating ability (EDA) was 72.86%. Maximum nitrite-scavenging ability was 94.62% at microwave power, ethanol concentration, and extraction time of 81.83 W, 2.65%, and 3.83 min, respectively. Superoxide dismutase (SOD) showed maximum pseudo-activity of 49.12% at microwave power of 34.23 W, ethanol concentration of 33.11 %, and extraction time of 4.40 min. Based on superimposition of 4-dimensional RSM with respect to extraction yield, electron-donating ability, nitrite-scavenging ability, and pseudo-activity of SOD, optimum ranges of extraction conditions were microwave power of 0-100 W, ethanol concentration of 40-70%, and extraction time of 2-8 min.

Response Characteristics Effectiveness of Power Converter According to Using of Error Compensator for PV Power System (태양광 전력설비를 위한 오차 보상기 사용의 전력변환기기에 대한 응답특성의 효과 검증)

  • Kim, Dong-Eun;Lee, Hyun-Jae;Shon, Jin-Geun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.10
    • /
    • pp.1388-1394
    • /
    • 2018
  • In this paper, the improvement of the control response by using the error compensator to improve the stability of the control in the power conversion system is verified. Typically a closed loop control method is used to improve the control response characteristics in a traditional power conversion system and this is accomplished by generating a PWM waveform. In this paper, the newly constructed Type3 compensator to overcome the existing such as PI controller or Type2 compensator has been developed to improve the control stability of these closed loop control systems and the effectiveness of the use of error compensation devices was verified by presenting technique to improve stability and select its parameters by expanding the range of phase gains. Stability improvements are shown by the extension of the phase gain range and parameter selection techniques and the effects of using the error compensation device are verified accordingly.

An Analysis on Fault Response Characteristics in Low Voltage DC Distribution System (저압직류 배전계통의 고장응답 특성 분석)

  • Noh, Chul-Ho;Gwon, Gi-Hyeon;Song, Jong-Il;Han, Joon;Oh, Yun-Sik;Kim, Chul-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.6
    • /
    • pp.911-917
    • /
    • 2016
  • DC-based power system is paid attention as interests in energy efficiency and power quality are increased. However, standardization and researches for commercializing Low Voltage DC(LVDC) distribution system are still insufficient. Protection system, which is closely related with reliability, power quality, safety, and life expectancy of components in power system, is also included. This paper therefore analyzes fault response characteristics in LVDC distribution system as a preliminary study on protection schemes. A stepwise analysis on fault current from both AC/DC converter and DC/DC converter is performed and related expressions are derived. And then, modeling and simulation with various conditions are conducted by using ElectroMagnetic Transients Program (EMTP) to verify analysis results. Based on research results in the paper, direction for development of protection schemes for LVDC distribution system is suggested.