• 제목/요약/키워드: Power Reduction

검색결과 4,696건 처리시간 0.031초

IoT 기반 간헐적 이벤트 로깅 응용에 최적화된 효율적 플래시 메모리 전력 소모 감소기법 (Efficient Flash Memory Access Power Reduction Techniques for IoT-Driven Rare-Event Logging Application)

  • 권지수;조정훈;박대진
    • 대한임베디드공학회논문지
    • /
    • 제14권2호
    • /
    • pp.87-96
    • /
    • 2019
  • Low power issue is one of the most critical problems in the Internet of Things (IoT), which are powered by battery. To solve this problem, various approaches have been presented so far. In this paper, we propose a method to reduce the power consumption by reducing the numbers of accesses into the flash memory consuming a large amount of power for on-chip software execution. Our approach is based on using cooperative logging structure to distribute the sampling overhead in single sensor node to adjacent nodes in case of rare-event applications. The proposed algorithm to identify event occurrence is newly introduced with negative feedback method by observing difference between past data and recent data coming from the sensor. When an event with need of flash access is determined, the proposed approach only allows access to write the sampled data in flash memory. The proposed event detection algorithm (EDA) result in 30% reduction of power consumption compared to the conventional flash write scheme for all cases of event. The sampled data from the sensor is first traced into the random access memory (RAM), and write access to the flash memory is delayed until the page buffer of the on-chip flash memory controller in the micro controller unit (MCU) is full of the numbers of the traced data, thereby reducing the frequency of accessing flash memory. This technique additionally reduces power consumption by 40% compared to flash-write all data. By sharing the sampling information via LoRa channel, the overhead in sampling data is distributed, to reduce the sampling load on each node, so that the 66% reduction of total power consumption is achieved in several IoT edge nodes by removing the sampling operation of duplicated data.

증등도 치주염에서 칫솔모 도달이 힘든 부위의 치태 및 치은염 감소에 대한 Sonicare $Elite^{\Box}$ 의 효과 (Efficacy of the Sonicare $Elite^{\Box}$ in plaque removal and reduction of gingival inflammation from hard-to-reach sites of the moderate periodontitis)

  • 홍지연;정성원;엄유정;채경준;정의원;김창성;최성호;김종관
    • Journal of Periodontal and Implant Science
    • /
    • 제36권3호
    • /
    • pp.693-703
    • /
    • 2006
  • The purpose of this study was to evaluate the efficacy of the Sonicare $Elite^{(R)}$ power toothbrush in plaque removal and reduction of gingivitis from hard-to-reach sites of the moderate periodontitis compared to regular manual toothbrush in 12 week follow-up. 82 subjects with incipient to moderate periodontitis were randomly assigned to use either the manual or sonic brush, instructed in its use, and asked to brush 2 times a day for 2 minutes. Plaque scores were taken at baseline, 1, 4, 12 weeks using Silness & $L\ddot{o}e$ plaque index and gingival inflammation was assessed by the $L\ddot{o}e$ & Silness gingival index. The results were as follows. 1. The Sonicare $Elite^{(R)}$ power toothbrush showed a significant reduction(p<0.0001) of the plaque(Silness & $L\ddot{o}e$) and gingival inflammation(Loe & Silness). 2. The Sonicare $Elite^{(R)}$ power toothbrush showed a significant better reduction of plaque and gingivitis(p<0.05) than the manual toothbrush after 1, 4, and 12 weeks. 3. The Sonicare $Elite^{(R)}$ power toothbrush demonstrated a significant reduction(p<0.0001) of the plaque in interproximal sites(p<0.0001), buccal sites(p<0.0001) and the lingual sites(p=0.00l8) of the teeth. 4. The Sonicare $Elite^{(R)}$ power toothbrush demonstrated a significant reduction(p<0.0001) of the gingival inflammation in the interproximal sites(p<0.0001), the buccal sites(p<0.0001) and the lingual sites(p<0.0001) of the teeth. The results of this study support the findings that Sonicare $Elite^{(R)}$ power toothbrush has a great potential to remove the plaque and resolve the gingival inflammation during the period of 12 week.

Peak-to-Average Power Ratio (PAPR) Reduction Techniques of OFDM Signals

  • Lee, Byung-Moo
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.7-8
    • /
    • 2008
  • It is well-known that one of the most serious problems of Orthogonal Frequency Divison Multiplexing (OFDM) is its high Peak-to-Average Power Ratio (PAPR) which seriously limits the power efficiency of High Power Amplifier (HPA). This paper introduces various methodologies to cope with this problem.

  • PDF

Coordinated Wide-Area Regulation of Transmission System for Voltage Profile Improvement and Power Loss Reduction

  • Asadzadeh, Babak;Golshannavaz, Sajjad
    • Transactions on Electrical and Electronic Materials
    • /
    • 제18권5호
    • /
    • pp.279-286
    • /
    • 2017
  • In this paper, an optimal approach for the wide-area regulation of control devices in a transmission network is proposed. In order to realize an improved voltage profile and reduced power loss, existing devices such as tap-changing transformers, synchronous machines, and capacitor banks should be controlled in a coordinated and on-line manner. It is well-understood that phasor measurement units in transmission substations allow the system operators to access the on-line loading and operation status of the network. Accordingly, this study proposes efficient software applications that can be employed in area operation centers. Thus, the implanted control devices can be regulated in an on-line and wide-area coordinated approach. In this process, efficient objective functions are devised for both voltage profile improvement and power loss reduction. Subsequently, sensitivity analysis is carried out to determine the best weighting factors for these objectives. Extensive numerical studies are conducted on an IEEE 14-bus test system and a real-world system named the Azarbayjan Regional Transmission Network. The obtained results are discussed in detail to highlight the promising improvements.

흡음재의 배치와 임피던스 선정을 통한 음원 방사파워 제어와 전역 소음 감소 (Acoustic Source Power Control and Global Noise Reduction by Selection of Distribution and Impedance of Absorptive Materials in Acoustically Small Enclosures)

  • 김양한;조성호
    • 한국소음진동공학회논문집
    • /
    • 제14권8호
    • /
    • pp.668-674
    • /
    • 2004
  • The possibility of global noise reduction by the sound power control through selection of distribution and impedance of absorptive materials is discussed. It is necessary to investigate the relation between the global sound energy in the field and the total sound power radiated by sources. In the previous work,$^{(1.2)}$ the authors presented a useful design method to change boundary condition that can be useful to reduce noise in acoustically small enclosures. Changing boundary condition Is related to not only enclosure’s geometrical shape but also acoustical treatment on walls for example, attaching of impedance patches (ex: absorptive material). In many practical situations, we often meet situation to change acoustical treatment on walls. The possibility of total acoustic potential energy(globa1 noise) reduction by acoustic source power control is examined in an acoustically small cavity Using acoustic energy balance equation, the relation between global noise control performance and absorptive material’s arrangement/impedance is deduced. Numerical simulation is performed to interpret its physical meaning in terms of absorbent’s distribution and impedance.

지중송전케이블계통에서 절연통의 과전압 해석 및 억제대책 검토 (Analysis of Overvoltage and Reduction Methods of Insulation Joint Box in Underground Power Cable Systems)

  • 홍동석;정채균;이종범;서재호;조한구
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권2호
    • /
    • pp.102-108
    • /
    • 2002
  • This paper describes the overvoltage analysis and reduction methods of insulation joint boxes in underground transmission power cables when direct lightning surge strikes to overhead transmission line. An actual 154kV combined transmission line with underground Power cables was modelled in ATPDraw for simulation. Simulations were performed to analyze the overvoltage between insulation joint boxes, sheath-to-ground voltage according to the distance between cable conductors, cable lengths, burying types, CCPU connection types. The most effective method to reduce the induced overvoltage of Insulation joint boxes was proposed. It is evaluated that the proposed reduction method riven from the detailed simulations can be effectively applied to the actual underground power cable systems.

Concept Development of Core Protection Calculator with Trip Avoidance Function using Systems Engineering

  • Nascimento, Thiago;Jung, Jae Cheon
    • 시스템엔지니어링학술지
    • /
    • 제16권2호
    • /
    • pp.47-58
    • /
    • 2020
  • Most of the reactor trips in Korean NPPs related to core protection systems were caused not because of proximity of boiling crisis and, consequently, a damage in the core, but due to particular miscalculations or component failures related to the core protection system. The most common core protection system applied in Korean NPPs is the Core Protection Calculator System (CPCS), which is installed in OPR1000 and APR1400 plants. It generates a trip signal to scram the reactor in case of low Departure from Nucleate Boiling Ratio (DNBR) or high Local Power Density (LPD). However, is a reactor trip necessary to protect the core? Or could a fast power reduction be enough to recover the DNBR/LPD without a scram? In order to analyze the online calculation of DNBR/LPD, and the use of fast power reduction as trip avoidance methodology, a concept of CPCS with fast power reduction function was developed in Matlab® Simulink using systems engineering approach. The system was validated with maximum of 0.2% deviation from the reference and the dynamic deviation was maximum of 12.65% for DNBR and 6.72% for LPD during a transient of 16,000 seconds.

NREL 5MW 풍력터빈 제어용 저주파 통과 필터와 드라이브 트레인 댐퍼의 효과 고찰 (A Study on the Effect of Low Pass Filter and Drive Train Damper for the NREL 5MW Wind Turbine Control)

  • 임채욱
    • 한국산업융합학회 논문집
    • /
    • 제24권4_2호
    • /
    • pp.443-451
    • /
    • 2021
  • It is essential to examine and analyze the power output and load responses together using real-world turbulent wind speeds. In this paper, the power controller and the drive train damper are simultaneously considered using the NREL 5MW wind turbine model, and the damage equivalent load(DEL) of the low speed shaft torque and power output responses according to the natural frequency of the second order low pass filter are simultaneously investigated. Numerical testing is carried out above rated wind speed using commercially available Bladed software. From the viewpoints of DEL reduction of the drive train shaft torque and power output responses, it is shown that the natural frequency of the low pass filter is appropriately about 6 to 10rad/s. And the reduction ratio of the DEL of the low-speed shaft torque decreases as the wind speed becomes higher, and it is confirmed that the reduction ratio is limited to about 20% at high wind speeds.

다층 퍼셉트론을 이용한 인버터의 효율 감소 진단 모델에 관한 연구 (Research on Model to Diagnose Efficiency Reduction of Inverters using Multilayer Perceptron)

  • 정하영;홍석훈;전재성;임수창;김종찬;박철영
    • 한국멀티미디어학회논문지
    • /
    • 제25권10호
    • /
    • pp.1448-1456
    • /
    • 2022
  • This paper studies a model to diagnose efficiency reduction of inverter using Multilayer Perceptron(MLP). In this study, two inverter data which started operation at different day was used. A Multilayer Perceptron model was made to predict photovoltaic power data of the latest inverter. As a result of the model's performance test, the Mean Absolute Percentage Error(MAPE) was 4.1034. The verified model was applied to one-year-old and two-year-old data after old inverter starting operation. The predictive power of one-year-old inverter was larger than the observed power by 724.9243 on average. And two-year-old inverter's predictive value was larger than the observed power by 836.4616 on average. The prediction error of two-year-old inverter rose 111.5572 on a year. This error is 0.4% of the total capacity. It was proved that the error is meaningful difference by t-test. The error is predicted value minus actual value. Which means that PV system actually generated less than prediction. Therefore, increasing error is decreasing conversion efficiency of inverter. Finally, conversion efficiency of the inverter decreased by 0.4% over a year using this model.

대형 상용 엔진에서 SCR의 클리닝 주기 선정 및 저감효율에 따른 내구신뢰성 특성 연구 (Cleaning Interval Selection for SCR Considering Endurance Reliability and Emissions Reduction Efficiency in Heavy Duty Commercial Engine)

  • 신재식;강정호;김형준
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제18권1호
    • /
    • pp.66-71
    • /
    • 2018
  • Purpose: Performance recovered from SCR through cleaning was studied, measuring differential pressure, NOx reduction efficiency, fuel consumption and engine power before and after cleaning. Ideal cleaning intervals are proposed based on SCR mileage and differential pressure. SCR endurance and reliability improvements through cleaning were studied through physicochemical testing of SCR durability at 43,000km 50,000km, and 110,000km respectively. Methods: Engine power, fuel consumption and exhaust gas were measured using engine full load tests and ND-13 MODE by installing the SCR before cleaned at total engine mileages of 400,000 km, 300,000km and 200,000km. The same tests were performed after cleaning the SCR catalytic converter. Endurance and reliability of the SCR cleaning was studied through the same test by SCR catalyst after each 43,000km 50,000km, 110,000km, durability test on SCR cleaning. Conclusion: We confirmed the low-performance of the SCR due to clogging is restored by SCR cleaning technology. The NOx reduction efficiency was restored to 82%, 86% and 88% from 69%, 72% and 79%. As well as the NOx reduction efficiency, it was confirmed that the engine power, fuel consumption and back pressure was restored to fresh SCR levels. As a result of the durability and reliability achieved through SCR cleaning, we confined the appearance and reduction efficiency through visual inspection and ND-13 MODE are similar to new SCR catalysts. Finally, it was judged that there was no change in performance even when driving the SCR without cleaning throughout the 100,000 km mileage warranty.