A Power Quality Monitoring System(PQMS) : A Standard of User-Friendly-GUI & Analysis Graphic Representation (전력품질 모니터링 시스템 : User-Friendly-GUI 및 분석 그래프 표준)

  • Kim, Young-Il;Han, Jin-Hee;Yoon, Tai-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.127-130
    • /
    • 2002
  • Recently, with the increasing use of power semiconductors and microprocessors which are very sensitive to little change of power quality and for coping positively with anticipating power quality disputes between power providers and consumers which are possible to occur by of power market being formed, the power quality problem has gained preponderance among the contemporary research areas. To serve these purposes, the integrated system has been researched and developed for power quality analysis and monitoring, which provides speedy and powerful functions by the growth of computer hardware and information technology. But the advent of fast and lower price hardware make little difference in an application on many systems. As a result, the key issues of constructing power quality monitoring system are in the management of data obtained, accurate algorithms, graphic representation and user-friendly-environment for easy and clear analysis results. So, in this paper it will be introduced that the standard of user-friendly-GUI(Graphic User Interface) and analysis graphic representation for intuitive understanding of results from power quality analysis based on consideration of several systems currently being in use.

  • PDF

Using Protective Relaying for Power Quality Monitoring (보호계전기를 이용한 전기품질 감시 기법 연구)

  • Bea, Y.J.;Lim, S.I.;Choi, I.S.;Lee, S.J.;Kim, J.H.;Kim, B.J.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.62-64
    • /
    • 2002
  • Power quality monitoring system is devoted to more concern than before, because the innovation of industrial technology needs more accurate instruments and more advanced power quality. Therefore, this paper is proposed to use digital protective relays for power quality monitoring. In addition, taking power quality events, Electrical magnetic phenomenon of IEEE std 1159, proposing that adaptive power quality event list consider limitation memory capacity and signal processing ability of protective relay. The prototype S/W of power quality analysis is also developed. Especially this prototype S/W analysis scheme is verified through many kinds of power quality events (gathering protective relay data) in EMTP simulation.

  • PDF

Development of Power Quality Monitoring System(PQMS) : Database Design for PQMS (전력품질 감시 시스템 개발(1): 전력품질 데이터베이스 설계)

  • Kim, Young-Il;Bahng, Soon-Jung;Han, Jin-Hee;Yun, Tae-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.128-130
    • /
    • 2003
  • Recently, with the increasing use of power semiconductors and microprocessors which are very sensitive to little change of power quality and power market being formed according to the reorganization of the power market, power providers and consumers show much interest in the power quality problem. This situation makes the demand creation of integrated system for power quality analysis and monitoring based on speedy and powerful functions by the growth of computer hardware and information technology, and besides advanced corporation already have created and employed power quality analysis and monitoring system. In this papers, it will be introduced that power quality database design-database is essential to integrated system-for managing effectively and confidently data from the power quality meters(PQM).

  • PDF

Power Quality Measurement and Analysis of Extra-High Voltage Customer (특고압 수용가의 전력품질 측정 및 분석)

  • Cho, Jae-Hyeong;Lee, Jong-Pil;Ji, Pyeong-Shik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.4
    • /
    • pp.286-290
    • /
    • 2015
  • Power system is composed of a number of power devices and equipment. This factor affects the power quality is also displayed very complicated and varied. The accurate measurement and analysis of the causes of power quality problems is difficult. In preparing for these issues, there are many difficulties. In this study, Power quality of A public establishment of Chungbuk province were measured and analyzed. Measurement results of the fifth harmonic current was very large. Accordingly, the harmonic reduction will be needed. This research will be utilized as fundamental data to improve power quality for power utility and customer.

A web-based power quality monitoring system in the Substation Automation System (변전소 자동화 환경에서 웹 기반 전기품질 감시 시스템)

  • Park D. H.;Lim S. J.;Shin J. H.;Lim S. I.;Lee S. J.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.378-380
    • /
    • 2004
  • Along with the increase of the importance of power quality, many various systems are dedicated in the analysis of power quality nowadays. But there still exists the same problems for realizing such kind of analysis systems well. One is the customization of the power quality measure devices; The other is an economic problem. This paper presents the usefulness and the advantage of the ICD (Intelligent Electronic Device) as the measure device of power quality And this paper detailedly describes the development procedure of web-based power quality monitoring system through ActiveX controls. Now this power quality monitoring system is already applied to the substation automation system.

  • PDF

The Development of Integrated Power Quality Diagnosis System for Power System (전력계통 전력품질 통합진단시스템 개발)

  • Kwak, N.H.;Jeon, Y.S.;Park, S.H.;Lee, I.M.;Park, H.C.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.277-279
    • /
    • 2005
  • Recently, due to the increase of power conversion devices and nonlinear loads with the development of information, communication and control technologies, the instantaneous minute interruption factors such as voltage & current harmonics, surge occurring frequency, instantaneous voltage variation, voltage unbalance, flicker etc. have greatly threatened the power quality, and the deterioration of electric power facilities and the functional error of controllers are increasing. As such an instantaneous minute interruption appears to be small and local, accurate evaluation with measurement is difficult and total analysis system is required through a wide range of power quality effect analysis such as the simultaneous measurement on various power supply phenomena and the analysis on the interrelation with system loads. Most of conventional power quality diagnosis equipments have beer developed and applied, which were able to measure the stability rate of frequency, the stability rate of voltage, the electricity-failure duration etc, However, they were insufficient to analyze the system present situation, understand the cause of the failure occurred by the problem of power quality and analyze out the phenomena. Accordingly, this study will address the development of the system for a wide range of power quality diagnosis over the present level, the system for supporting the determination such as the analysis on risk factors, failure mode and impact, the system for harmonic evaluation based on international standards(IEC 61000 Series) and the total power quality diagnosis network & system with the extension and openness as a local and national-scale broadband power quality diagnosis system.

  • PDF

A Study on Power Quality Detection Method of Utility interconnected Distributed Generation (분산전원이 연계된 배전계통에서의 전압품질 검출에 관한 연구)

  • Lee, B.Y.;Kim, J.C.;Jung, S.B.
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.252-254
    • /
    • 2004
  • This paper studies power quality problem of utility interconnected distributed generation. Recently, electronic devices that are sensitive to power quality have been increasing. Both utility and customer are interested in power quality problem. Therefore, we studied an effect of utility power quality caused by distributed generation. We detect and analysis voltage sag which is one of power quality indicator. Also, we used Matlab to simulate power quality problem.

  • PDF

Performance Analysis of UPQC(Unified Power Quality Conditioner) with Compensation Capability for Voltage Interruption (순간정전에 대한 보상능력을 갖는 UPQC(Unified Power Quality Conditioner)의 성능해석)

  • 김희중;배병열;한병문;설승기;조보형
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.5
    • /
    • pp.279-286
    • /
    • 2003
  • A new UPQC(unified power quality conditioner), which consists of series inverter, shunt inverter, dc/dc converter, and energy storage, is proposed. The proposing UPQC can compensate reactive power, harmonics, voltage sag and swell, voltage unbalance, and voltage interruption. The control strategy for the proposing UPWQC was derived using the instantaneous power method. The performance of proposing system was analyzed by means of the EMTDC/PSCAD simulation and the experimental work with the hardware prototype. The proposing UPQC has the ultimate capability of improving power quality at the point of installation on power distribution systems or industrial power systems and can be utilized for the custom power device in the future distribution system.

Performance Analysis for the UPQC(Unified Power Quality Conditioner) Interconnected to the Distributed Generation System (분산전원 연계형 UPQC(Unified Power Quality Conditioner)의 성능해석)

  • 김희중;배병열;한병문
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.3
    • /
    • pp.152-160
    • /
    • 2004
  • A novel UPQC(Unified Power Quality Conditioner), which consists of series inverter, shunt inverter, distributed generation system, is proposed. The proposing system can compensate reactive power, harmonics, voltage sag and swell, voltage interruption etc. through the change of paralleling operation mode and islanding operation mode. The control strategy for the proposing system was derived using the instantaneous power method. The performance of proposing system was analyzed by means of the PSCAD/EMTDC simulation and the experimental work with the hardware prototype. The proposing system has the ultimate capability of improving power quality at the point of installation on power distribution systems or Industrial power systems and can be utilized for the custom power device in th future distribution system.

A Power Quality Analysis of a Photovoltaic System (태양광 발전설비 전력품질 분석)

  • Jung, Jong-Wook;Kim, Sun-Gu;Choi, Myeong-Il
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.579-584
    • /
    • 2009
  • This paper describes a power quality analysis of a photovoltaic generating systems. Prior to the power measurement, domestic and foreign codes related to the photovoltaic generating systems were briefly summarized. After constructing about 5 kW photovoltaic systems, input/output voltages and currents were measured to compare and analyze the power quality by the module type. Based on the measured values, a couple of factors such as active power, power factor, total harmonic distortion(THD) was calculated and analyzed.