• 제목/요약/키워드: Power Mode

검색결과 4,686건 처리시간 0.029초

Optimal Duplex Selection for Decode and Forward Relay Systems with Power Allocation

  • Kwon, Taehoon;Lim, Sungmook
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제10권12호
    • /
    • pp.5347-5360
    • /
    • 2016
  • In decode and forward relay systems, choosing the duplex mode is an important factor to the performance. To satisfy the performance requirement, self-interference must be mitigated for the full-duplex relay (FDR), and the resource efficiency must be increased for the half-duplex ratio (HDR). Therefore, if a wise scheme to consider these two factors exists, decode and forward relay systems are used more effectively. This study proposes a new duplex selection scheme for decode and forward relay systems. The proposed duplex selection scheme chooses the better duplex mode according to the channel statistical conditions with optimal power allocation. The simulation results show that the proposed duplex scheme with optimal power allocation has lower outage probability than the FDR and the HDR.

DC 배전을 위한 다중 모드 단일 인덕터 컨버터 (Multi-Mode Single Inductor Converter for DC Grid System with a Battery)

  • 김지연;김재국
    • 전력전자학회논문지
    • /
    • 제25권5호
    • /
    • pp.343-349
    • /
    • 2020
  • This study proposes a new single inductor converter for DC grid systems. A conventional system is composed of two independent converters for controlling battery and load. This system is simple but it has two inductors that affect power density and efficiency. The proposed converter can reduce the number of inductors by integrating the two converters and relieve voltage stress on switches by using a battery switching cell. Accordingly, power density and efficiency can be improved using a single inductor and lower voltage-rated switches. A prototype of a 500 W converter is built, and each mode is experimented on to confirm the validity of the proposed converter.

Nd:YVO$_4$ 마이크로칩 레이저의 단일 종모드 동작 (Single Longitudinal Mode Operation in Nd:YVO$_4$ Microchip Laser)

  • 지명훈;김교준;이영우
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권6호
    • /
    • pp.260-264
    • /
    • 2002
  • We developed LD Pumped Nd:$VVO_4$ microchip laser with the cavity length of 1mm. The microchip laser output was 87.5㎽ at the wavelength of 1063.9nm with the input power of 241㎽ at the wavelength of 809nm. The slope efficiency was 40.7% and the threshold input power was 31.1㎽. We have also defined input power limit for the single longitudinal mode operation theoretically. It was 2.5 times larger than that of threshold input intensity. According to the results of simulation, the Nd:YVO$_4$ microchip laser can be operated with the maximum output of 15㎽ for the single longitudinal mode up to the input power of 77.75㎽.

Carrier Based Common Mode Voltage Reduction Techniques in Neutral Point Clamped Inverter Based AC-DC-AC Drive System

  • Ojha, Amit;Chaturvedi, Pradyumn;Mittal, Arvind;Jain, Shailendra
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.142-152
    • /
    • 2016
  • Common mode voltage (CMV) generation is a major problem in switching power converter fed induction motor drive systems. CMV is the zero sequence voltage generated due to the switching action of power converters. Even a small magnitude of CMV with a high rate of change may circulate large bearing currents which may damage a machine's bearings and shorten its life. There are several methods of controlling CMV. This paper presents 3-level sinusoidal pulse width modulation based techniques to control the magnitude and rate of change of CMV in multilevel AC-DC-AC drive systems. Simulation and experimental investigations have been presented to validate the performance of proposed technique to control CMV in 3-level neutral point clamped inverter based AC-DC-AC system.

Design and Analysis of an Interleaved Boundary Conduction Mode (BCM) Buck PFC Converter

  • Choi, Hangseok
    • Journal of Power Electronics
    • /
    • 제14권4호
    • /
    • pp.641-648
    • /
    • 2014
  • This paper presents the design considerations and analysis for an interleaved boundary conduction mode power factor correction buck converter. A thorough analysis of the harmonic content of the AC line current is presented to examine the allowable voltage gain (K value) for meeting the EN61000-3-2, Class D standard while maximizing efficiency. The results of the harmonic analysis are used to derive the required value of K and therefore the output voltage necessary to meet the class D requirements for a given AC line voltage. The discussed design consideration and harmonic current analysis are verified on a 300W universal line experimental prototype converter with an 80V output. The measured efficiencies remain above 96% down to 20% of the full load. The input current harmonics also meet the IEC61000-3-2 (class D) standard.

가변 스텝 P&O 기반 전압제어 MPPT 알고리즘에 관한 연구 (A Novel Voltage Control MPPT Algorithm using Variable Step Size based on P&O Method)

  • 김지찬;차한주
    • 전력전자학회논문지
    • /
    • 제25권1호
    • /
    • pp.29-36
    • /
    • 2020
  • In this study, a variable step algorithm is proposed on the basis of the perturb and observe method. The proposed algorithm can follow the maximum power point (MPP) quickly when solar irradiance changes rapidly. The proposed technique uses the voltage change characteristic at the MPP when the environment changes because of insolation or temperature. The MPP is tracked through the voltage control using a variable step method. This method determines the sudden change of solar irradiance by setting the threshold value and operates in fast tracking mode to track the MPP rapidly. When the operation point reaches the MPP, the mode switches to the variable step mode to minimize the steady state error. In addition, the output disturbance is decreased through the optimization of the control method design. The performance of the proposed MPPT algorithm is verified through simulation and experiment.

스위칭 모드 직류 전원공급기(SMPS)의 전도성 잡음해석 (Conducted Noise Analysis of SMPS(Switching Mode Power Supply))

  • 성주영;김윤명
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2000년도 종합학술발표회 논문집 Vol.10 No.1
    • /
    • pp.286-291
    • /
    • 2000
  • 본 논문에서는 일반적인 EMI 노이즈 개요 및 SMPS(Switching Mode Power Supply)에서의 Noise 발생 메카니즘을 분석하고, 전도성 Noise를 측정하였으며, SMPS에서 발생되는 잡음행태를 분석하여 대책방법을 연구하였다.

  • PDF

Transformer-Reuse Reconfigurable Synchronous Boost Converter with 20 mV MPPT-Input, 88% Efficiency, and 37 mW Maximum Output Power

  • Im, Jong-Pil;Moon, Seung-Eon;Lyuh, Chun-Gi
    • ETRI Journal
    • /
    • 제38권4호
    • /
    • pp.654-664
    • /
    • 2016
  • This paper presents a transformer-based reconfigurable synchronous boost converter. The lowest maximum power point tracking (MPPT)-input voltage and peak efficiency of the proposed boost converter, 20 mV and 88%, respectively, were achieved using a reconfigurable synchronous structure, static power loss minimization design, and efficiency boost mode change (EBMC) method. The proposed reconfigurable synchronous structure for high efficiency enables both a transformer-based self-startup mode (TSM) and an inductor-based MPPT mode (IMM) with a power PMOS switch instead of a diode. In addition, a static power loss minimization design, which was developed to reduce the leakage current of the native switch and quiescent current of the control blocks, enables a low input operation voltage. Furthermore, the proposed EBMC method is able to change the TSM into IMM with no additional time or energy loss. A prototype chip was implemented using a $0.18-{\mu}m$ CMOS process, and operates within an input voltage range of 9 mV to 1 V, and an output voltage range of 1 V to 3.3 V, and provides a maximum output power of 37 mW.

스위치모드 컨버터에 의한 새로운 슬립전력 회수시스템 (A New Slip Power Recovery System by Switch Mode Converter)

  • 박한웅;박성준;김철우;황영문
    • 전력전자학회논문지
    • /
    • 제4권1호
    • /
    • pp.73-81
    • /
    • 1999
  • 본 연구에서는 권선형 유도전동기의 회전자회로에 스위치모드 컨버터를 적용시킨 새로운 슬립전력 회수시스템을 제안하고 이를 분석한다. 제안된 시스템의 해석을 통해 적용된 컨버터의 듀티비에 의해 속도가 제어될 수 있으며, 동시에 기존 시스템의 몇가지 특성을 개선할 수 있음을 보인다. 특히 종래 시스템에서 주된 단점으로 되어 있는 저역률 및 전원전류의 고조파성분을 크게 개선할 수 있을 뿐만 아니라 선형적인 속도조절도 가능하다. 제안된 시스템의 타당성을 보이기 위해 이론 및 실험 결과를 제시하고 이를 설명한다.

빌딩용 직류배전 시스템의 3상 AC/DC 컨버터의 기동 시 과도상태 응답 개선 (Transient Response Improvement at Startup of Three Phase AC/DC Converter for DC Distribution System in Building Applications)

  • 신수철;이희준;이정효;나종국;원충연
    • 전력전자학회논문지
    • /
    • 제18권2호
    • /
    • pp.138-144
    • /
    • 2013
  • Most of the DC loads have had the sensitive characteristics electrically for input voltage. In this system, power converter is operated after connecting with DC loads to minimize the overshoot of the control voltage that may occur during connection of the loads. But whenever starting the power converter, parameters in circuit are different because power converter has been connected with diverse load types at each startup time. This is cause of a disadvantage to PI controller design of power converter. In this paper, the novel voltage control method using sliding mode control theory has proposed. This control method minimizes the overshoot of control voltage at startup of power converter. Despite the variations of the system parameters, the proposed voltage controller has fast response and robustness characteristics such as PI and sliding mode controllers. The proposed controller was applied to the three-phase AC/DC converter and each performance of controller was verified.